Sparse Distributed Fiber Optic Sensor Placement in Metropolitan and Datacenter Elastic Optical Networks

Sleman Mouammar, Ítalo B. Brasileiro, André Drummond

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

SLEMAN MOUAMMAR 1,∗^{1,*}, ÍTALO B. BRASILEIRO 1^{1}, AND ANDRÉ DRUMMOND 2^{2}

1^{1} Technische Universität Braunschweig, Germany

2^{2}Department of Computer Science, University of Brasília, Brazil

Compiled October 5, 2026

Distributed Fiber Optical Sensing (DFOS) leverages optical backscattering signals to predict failure events and enable proactive Just-In-Time (JIT) restoration. Modern network infrastructures have optical components and fibers as key enablers of high throughput and low latency. The integration of sensing features in this optical infrastructure adds features such as network diagnosis, spatial positioning and sensing, and opens up opportunities for the implementation of intelligent network control expected for the next-generation networks. In this paper, we study how the quantity and the placement of the DFOS devices in an all-optical network can mitigate failure events. In our evaluation, we consider metropolitan and data center elastic optical networks. This work also evaluates sensing devices with various prediction time capabilities, in order to assess their effectiveness when considering a variable number of deployed devices and different placement heuristics. The evaluation uses key performance metrics, including the bandwidth blocking rate, number of affected circuits by failure events, and the service downtime. Simulation results demonstrate that the Greedy Shortest Path Coverage (GSPC) heuristic substantially reduces the number of circuits affected by failure when DFOS devices cover only 5% of links, while 25% coverage shows a performance gain comparable to the full coverage scenario, which is an opportunity for significant cost reduction. Finally, for the 5% sensing coverage scenarios, our results illustrate that prediction windows of 15 ms and 7.5 ms are sufficient for JIT restoration in metropolitan and data center networks, respectively.

http://dx.doi.org/10.1364/ao.XX.XXXXXX

1. INTRODUCTION

Integrated Sensing and Communication (ISAC) represents an emerging paradigm that unifies environmental sensing and data communication in a shared waveform, spectrum, and hardware infrastructure. ISAC enables capabilities such as object detection, tracking, recognition, behavior analysis, and environmental awareness. ISAC is gaining traction in industrial applications among telecommunications vendors, including Huawei in vehicular networks, Ericsson in smart urban infrastructure, and Qualcomm in autonomous driving and IoT systems [1]. Furthermore, standardization bodies such as 3GPP, ETSI, and IEEE [2] are formalizing concepts to support the expanding range of ISAC use cases anticipated for 6G networks, in which network infrastructure sensing and monitoring is a key requirement when providing services such as fast recovery and high-availability.

Distributed Fiber Optic Sensing (DFOS) enables the integration of ISAC into the network by providing sensing capabilities for acoustic, vibration, temperature, and strain, and thus enabling communication with additional sensing services, such as traffic and security monitoring, fire monitoring and prevention, detection of water leakage, and structure change, as reported in [3]. DFOS systems read back-scattered optical signals in fibers to function as continuous sensors that monitor tens of kilometers of infrastructure. Because of that, the deployment of high-precision DFOS technology has the potential to replace thousands of local discrete point sensors across network links, bringing significant Capital Expenditure (CapEx) savings. In order to further optimize cost savings, DFOS devices can be strategically positioned at sparse locations, with the aim of maintaining a good monitoring coverage with reduced number of deployed sensing devices. This sparse DFOS placement problem has been formally proven to be NP-hard [4], and it is affected by multiple factors, such as the traffic pattern, the topological layout, and the sensing device efficiency. While sensor placement has been addressed in the literature, the impacts of such deployment strategies on network performance and survivability are still a research gap. Figure 1 exemplifies the sparse DFOS placement problem.

Figure

Fig. 1. DFOS sparse distribution in an 8-node network: scenario with sensors placed at nodes A and D, and failure events (fiber cuts) to take place at unidirectional links A→CA \rightarrow C and D→ED \rightarrow E.

Fig. 1 illustrates a network with two DFOS-enabled nodes deployed to monitor failure occurrence in a set of unidirectional links ( A→CA \rightarrow C and D→ED \rightarrow E), further enabling circuit restoration. In the depicted snapshot, one circuit A→C→D→EA \rightarrow C \rightarrow D \rightarrow E (blue) traverses the link A→CA \rightarrow C, and three circuits, A→C→D→EA \rightarrow C \rightarrow D \rightarrow E (blue), A→D→E→HA \rightarrow D \rightarrow E \rightarrow H (green) and B→D→E→FB \rightarrow D \rightarrow E \rightarrow F (yellow) traverse the bottleneck link D→ED \rightarrow E. In both links, a failure is about to occur. If the DFOS device is deployed only at node A, the proactive restoration will only reallocate one-third (blue) of the affected circuits, while the remaining circuits will experience disruption. In the case of site D holding a DFOS, the failure on the central link is detected in advance, and all three affected circuits are proactively reallocated, reducing the impact of service disruption. In previous work [5], we exploited DFOS as an enabler for Just-In-Time (JIT) (proactive) restoration to demonstrate that one could achieve high network resilience to link failures without paying the resource over-allocation costs of a protection mechanism. In that study, DFOS were enabled in all network nodes, which is a strong assumption. The results showed a circuit disruption reduction by more than 90% in a metropolitan Elastic Optical Network (EON).

This paper moves further to investigate the impact of sparse DFOS placement on failure prediction, which is a practical deployment scenario that will be considered in real networks. The main contribution is threefold: (i) we evaluate the impact of DFOS sparse placement for failure prediction in metropolitan and data center (DC) EONs, (ii) we adapt a set of heuristics for DFOS sparse placement and propose the Greedy Shortest Path Coverage (GSPC) solution as an attempt to mitigate the impact of failures, and (iii) we analyze the impact of deploying different types of DFOS based on different failure prediction window capability. Our findings indicate that, besides reducing the impact of failures, different DFOS sparse placement solutions significantly influence the outcomes. Simulation results further show that deploying DFOS devices to monitor only 25% of network links has performance comparable to a network fully covered (sensed) by DFOS, which results in significant CapEx savings. Furthermore, DFOS devices with a 15 ms failure prediction window provide the most effective and efficient service maintenance, even with only 5% of monitored links.

The rest of the paper is organized as follows: section 2 presents the related work, section 3 details the proposed architecture, section 4 presents the DFOS placement heuristics, section 5 discusses the numerical results, and section 6 presents conclusions and related future work.