arXiv:2610.03419cs.LGOct 2026

Manuscript Offprint

arXiv:2610.03419

Deep Bayesian REFoCUS

Simon Penninga, Ruud van Sloun

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Simon W. Penninga and Ruud J. G. van Sloun

Abstract—In this work we formulate ultrasound multistatic recovery from arbitrary transmit sequences as a Bayesian inference problem. To that end, we train a deep generative prior on multistatic data sets to tackle the rank-deficient regime in which classical linear REFoCUS decoders fail. This approach, which we term Deep Bayesian REFoCUS, outperforms the linear baselines for all regimes of rank-deficiency and noise levels, and regresses to linear decoding when inversion is exact. The model also expresses uncertainty in the null space of the acquisitions, whereas the linear REFoCUS decoders only provide point estimates. Finally, we analyze the impact of distribution shift between simulation and in-vivo acquisitions, showing remarkable generalization ability without any fine-tuning or adaptation.

Index Terms—ultrasound imaging, multistatic recovery, full matrix capture, retrospective transmit beamforming, diffusion models, inverse problems, posterior sampling.

I. INTRODUCTION

THE diagnostic quality of a B-mode ultrasound image is strongly influenced by its transmit sequence. Classical line-by-line imaging focuses a series of transmits at spatial focal points, sweeping across the Field Of View (FOV). This achieves relatively high contrast and good resolution at the cost of frame rate due to the large number of transmits needed to cover the view. Ultrafast sequences such as plane-wave and diverging-wave transmission raise the frame rate by orders of magnitude but suffer from reduced contrast, worse lateral resolution, and a lower signal-to-noise ratio (SNR) [1], [2]. Coherent compounding of multiple steered transmits can recover part of the loss [1], [3], but the underlying trade-off between frame rate, SNR, and focusing quality remains. Moreover, coherent compounding of unfocused transmits that cover a large FOV is impacted by tissue motion across the transmit sequence, and generating sufficient tissue harmonics for harmonic imaging is more difficult.

In the linear regime, the multistatic dataset (recordings at every receive element for every transmit element firing individually) enables retrospective transmit and receive focusing with the full array entirely computationally, via linear combinations of timed single-element firings. However, acquiring a high-quality multistatic data set is challenging in practice, since sequential single-element firing severely limits SNR and frame rate [4].

With Retrospective Encoding For Conventional Ultrasound Sequences (REFoCUS) [5], the multistatic data set can instead be recovered from arbitrary transmit sequences. This is done by inverting the linear encoding of single-element responses. Recording the channel data of a conventional full-aperture sequence and applying the adjoint of the encoding (a re-delay-and-sum across transmit events) recovers an estimate of the complete data set but with full-aperture transmit SNR. This approach was later reformulated in the frequency domain and stabilized with Tikhonov regularization, extending recovery to steered and walking-aperture sequences [6]. However, both decoding methods yield estimates that are ultimately linear in the measurements, and exact inversion only holds for a set of noiseless transmits that is full rank.

In this paper we introduce Deep Bayesian REFoCUS (DB-REFoCUS) to tackle the rank deficiency constraint. In the rank-deficient regime, a learned prior can exploit statistical dependencies between observed and unobserved components to infer a distribution over plausible multistatic sets. Real multistatic data sets are highly structured and spatially coherent across the elements, and we train a deep generative model to capture this structure and to recover the multistatic data set through posterior sampling.

The recent introduction of diffusion and flow-matching models [7]–[10] has made learning large generative priors (e.g. images and videos) feasible, and posterior-sampling schemes [11]–[13] such as Diffusion Posterior Sampling (DPS) [14] have demonstrated the ability to solve ill-posed inverse problems. Here we show that these techniques can also be used to learn priors over raw ultrasound channel data. We link DPS guidance with the classical adjoint-based REFoCUS, and show that it can be directly used with any ultrasound sequence (without training for specific sequences), only requiring the specific acquisition operator at inference. Repeated sampling from the posterior gives us an ensemble whose spread represents epistemic uncertainty, which correlates strongly with model error. For an overview of DB-REFoCUS see Fig. 1.

In the remainder of this paper we review related work and derive a Bayesian representation of REFoCUS. We train a generative prior on idealized simulated multistatic data sets and evaluate on in vivo cardiac recordings of the Parasternal Long Axis (PLAX) view for various transmit counts.

References (46)