Quantifying Ethereum Energy Consumption via Network Mapping

Yahn Costa Hackspacher, Cornelius Ihle, Vasundhara Shaw, Dennis Trautwein, Geerd-Dietger Hoffmann, Bela Gipp, Moritz Schubotz

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

A Node-Level Estimate from Crawlable Attributes

Yahn Costa Hackspacher

FIZ Karlsruhe – Leibniz Institute for

Information Infrastructure

Karlsruhe, Germany

Yahn.Costa-Hackspacher@fiz-

Karlsruhe.de

Cornelius Ihle

University of Göttingen

Göttingen, Germany

ihle@gipplab.org

Dennis Trautwein

ProbeLab Analytics OÜ

Talinn, Estonia

dennis@probelab.io

Vasundhara Shaw

FIZ Karlsruhe – Leibniz Institute for

Information Infrastructure

Karlsruhe, Germany

Vasundhar.Shaw@fiz-karlsruhe.de

Geerd-Dietger Hoffmann

Department of Computer Science

University of Potsdam

Potsdam, Germany

didi@green-coding.io

Bela Gipp

University of Göttingen

Göttingen, Germany

gipp@uni-goettingen.de

Moritz Schubotz

FIZ Karlsruhe – Leibniz Institute for

Information Infrastructure

Karlsruhe, Germany

moritz.schubotz@fiz-karlsruhe.de

Abstract

Ethereum’s electricity use fell by about 99.95% after the network moved from proof of work to proof of stake. Service providers still need to report how much energy their operations use, e.g. under the EU Markets in Crypto-Assets Regulation (MiCAR). Existing estimates either apply one typical wattage to every node or start from aggregated monitoring counts. Both approaches ignore information that nodes already advertise on the peer-to-peer network: which client software they run, whether they use ARM or x86 hardware, where they are hosted, and whether they act as validators.

We combine crawls of the consensus and execution layers, assign a wattage to each peer from those attributes using published measurements, and estimate the remaining incomplete peers with a Random Forest. On 6,934 peers from two Nebula crawls (19 and 22 June 2026), the nodes that the crawler can reach sum to 415 kW, or 3.63 GWh if that draw were held for a year. Applying the same Lighthouse+Nethermind x86 wattage to every one of those peers instead yields 431 kW. Using the observed attributes therefore lowers the total by 3.9%, mainly because nodes at Hetzner and other non-AWS clouds draw less than that home-desktop figure. AWS then accounts for 15.6% of watts from 12.2% of peers, and validator-flagged nodes account for 31.4% of watts from 25.7% of peers.

Our snapshot of 415 kW is about 46% of the Cambridge Centre for Alternative Finance (CCAF) estimate of about 0.90 MW. Both approaches use about 60 W per node, so the gap is mostly how many nodes each estimate includes. The assignment rules cover 3,110 peers and the forest estimates the other 3,824. On held-out labeled peers with client, architecture, and OS hidden, the forest’s mean absolute error against the rule wattage is 4.3 W. Twenty-four-hour measurements on a gaming desktop differ from the predictions. After subtracting a 33 W idle graphics card that Ethereum clients do not need, both differences fall to about 19%.

CCS Concepts

• Networks → Network measurement; • Computer systems organization → Peer-to-peer architectures; • Hardware → Power and energy.