Manuscript Offprint

arXiv:2610.03546

ZeroMAG: Zero-Shot Multimodal Adapter Generation for Plug-and-Play EEG Foundation Models

Yubo Wang, Jingying Ma, Xinliang Zhou, Yangxuan Zhou, Jiquan Wang, Sha Zhao, Yiyuan Yang, Yi Ding, Ziyu Jia, Chenyu Liu, Cuntai Guan

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

ABSTRACT

EEG foundation models (EFMs) capture reusable knowledge from large-scale EEG data, while many EEG recordings also include companion physiological signals that provide complementary information beyond the EEG-only interface. The challenge is to preserve this pretrained knowledge while extending the EFM to heterogeneous multimodal recordings through an adaptation inferred from unlabeled target data. We introduce ZeroMAG, a zero-shot multimodal adapter generation framework that extends a frozen EEG encoder and prediction head using unlabeled target recordings, without target labels or target-side optimization. The target datasets are held out from all model training and selection in the ZeroMAG pipeline. ZeroMAG organizes companion modalities around a configuration-invariant adapter, constructs a modality–subject–task condition from unlabeled recordings and task context, and generates adapter weights in a function-constrained latent space learned from source adapters. Across six held-out target datasets and three EFM backbones, ZeroMAG improves balanced accuracy by 7.22 percentage points over EEG-only inference and 4.89 points over direct weight regression, while coming within 0.50 points of supervised multimodal adaptation on average. Ablations further show that removing functional supervision from either representation learning or conditional generation degrades generated-adapter performance, confirming the contribution of both components.

1 INTRODUCTION

Electroencephalography (EEG) is a non-invasive and widely used modality across clinical, cognitive, and brain–computer interface applications (Craik et al., 2019; Wolpaw et al., 2002; Lee et al., 2025). Its large and growing body of mostly unlabeled recordings has enabled EEG foundation models (EFMs) that learn reusable representations across downstream tasks (Kuruppu et al., 2025; Jiang et al., 2024; Wang et al., 2025; 2024a; Ma et al., 2026; Zhou et al., 2025).

EEG is increasingly recorded alongside companion signals that capture complementary physiological information, such as eye movements, muscle activity, and cardiac dynamics (Fig. 1(a)). Between 2016 and 2024, at least 124 deep learning studies combined EEG with EOG, EMG, ECG, or GSR (Lee et al., 2025), and concurrent EEG–fNIRS studies increased markedly after 2016 (Yeung & Chu, 2022); yet the number and type of available signals vary widely across datasets (Fig. 1(b)).

A common approach to exploiting these signals is multimodal physiological or general time-series foundation models (Thapa et al., 2024; Zhang et al., 2024; Fu et al., 2025). However, this often means training a new multimodal backbone instead of reusing the strong EEG representations already learned by existing EFMs, while also fixing the supported modality set in advance. Adapting an existing EFM is cheaper, but new recordings often arrive unlabeled because annotation requires expert review, making supervised adaptation for each target dataset impractical. Label-free adapta-

(a) Physiological Complementarity

Figure

Why not leverage such powerful auxiliary modal information?

(b) Multimodal EEG Landscape

Multimodal Prevalence by Task

Number of datasets containing each modality

ACC GSR Respiration ECG EMG EOG

Multimodal is a current trend within EEG research community.

(c) Cross-Dataset Performance

Figure 1: Multimodal EEG landscape and representative results. (a) Physiological information captured by common companion signals. (b) Publication trends, task-wise multimodal prevalence, and companion modality availability, based on prior surveys (Lee et al., 2025; Yeung & Chu, 2022). (c) Balanced accuracy on six held-out target datasets, comparing three EFM backbones with and without ZeroMAG against SleepFM and PhysioOmni.

tion can avoid target labels, but typically still requires target-side optimization (Liang et al., 2020; Wang et al., 2021). This raises the central question of this work:

Can multimodal capabilities be added to an existing EFM without target-side training?

Answering this question requires addressing three challenges.

C1: Heterogeneous modality configurations. EEG datasets differ in their companion signals: sleep recordings often include EOG and EMG, whereas emotion-recognition datasets may include eye movement. An adapter must accommodate these differences while allowing the available signals to contribute complementary information. The challenge is to accommodate arbitrary configurations across datasets within a single unified framework, without per-dataset redesign.

C2: Adaptation needs are target-dependent but labels are often unavailable. Even with the same companion signals, the appropriate adaptation differs across datasets and prediction tasks, so it must be determined for each target. However, target labels are usually unavailable because annotation is costly and requires expert review. The challenge is therefore to infer the target-specific adaptation from unlabeled recordings together with the task context.

C3: Parameter reconstruction does not ensure functional consistency. The generator is trained to reproduce adapters fitted on the source datasets. Two adapters with similar weights can still make different predictions, because the output is much more sensitive to some parameters than to others. A generator trained only to minimize parameter error may therefore produce adapters that are close to the targets in weight space but behave differently. The challenge is to make the generated adapters agree with the source adapters in their predictions.

To address these challenges, we propose ZeroMAG, which treats multimodal extension as personalized parameter generation: given unlabeled target recordings and task context, it directly generates a target-specific adapter while keeping the EFM fixed. A configuration-invariant adapter organizes reusable modality-specific blocks around a fixed EEG anchor (C1); a modality-subject-task condition captures target-specific information without dataset identifiers (C2); and function-constrained generation maps this condition to adapter parameters through a block-aligned latent space learned from fitted source adapters (C3).

Across six held-out target datasets and three EFM backbones, ZeroMAG improves balanced accuracy by 7.22 and 4.89 percentage points over EEG-only inference and direct weight regression, respectively, while coming within 0.50 points of supervised multimodal adaptation on average, and remains competitive with multimodal foundation models that require multimodal pretraining (Fig. 1(c)).

References (57)