Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu

Yuxuan Hu, Shilin Shan, Jianfei Yang, and Feng Xu

Abstract—Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

Index Terms—Heartbeat observability assessment, selective prediction, multi-task learning, sim-to-real transfer, millimeter-wave radar, contactless heart-rate estimation

I. INTRODUCTION

CONTACTLESS continuous heart-rate monitoring is increasingly important for everyday healthcare [1]. Healthcare and companion robots [2], [3] could provide this capability for pediatric and elderly care and chronic-condition management [4]. In camera-based physiological sensing, physiological priors support self-supervised and weakly supervised signal extraction [5], [6] and generalizable multi-task estimation [7]. Millimeter-wave (mmWave) radar offers a

(a) Simulation-Revealed Phenomena

Figure

(b) HEAR Predicts HR and Reliability

Simulated Supervision

Figure

Fig. 1. Motivation and overview of HEAR. (a) Simulated observations with similar motion projections can exhibit markedly different heartbeat observability, showing that geometry alone is insufficient to determine whether the heartbeat component is readable. This motivates assessment from the acquired signal. (b) Trained solely on simulated observations, HEAR is applied to real recordings without adaptation and jointly predicts an observability score and heart rate from the phase spectrum of each 25 s window. Heart-rate estimates are reported only for windows with predicted scores at or above the selection threshold.

privacy-preserving modality for contactless monitoring that can sense chest-wall micro-motion through clothing with submillimeter displacement sensitivity [8]. Its use in robotic interaction perception [9], privacy-preserving human–robot interaction [10], and fall detection [11] illustrates its broader role in human sensing. Extending radar-based physiological monitoring to everyday healthcare requires reliable heart-rate estimation [12].

Despite recent advances, mmWave heart-rate estimation remains sensitive to environments and postures [13], [14], [15]. Existing methods improve signal extraction through harmonic cancellation, mode decomposition, or learned regression [13], [16], [17], [18], or improve acquisition conditions through beamforming, multi-view placement, and orientation compensation [19], [20], [21], [22]. Yet an individual measurement may still lack a sufficiently distinct heartbeat component for reliable estimation. We refer to this measurement-specific readability as heartbeat observability. Many existing systems do not explicitly assess this property, making it difficult to distinguish reliable estimates from erroneous ones. We study

This work was supported by the Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China under Grant JYB2025XDXM110.

Yuxuan Hu and Feng Xu are with the Key Laboratory for Information Science of Electromagnetic Waves, Ministry of Education, School of Information Science and Technology, Fudan University, Shanghai 200433, China (e-mail:huyx23@m.fudan.edu.cn; fengxu@fudan.edu.cn). Yuxuan Hu is also with the School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798.

Shilin Shan and Jianfei Yang are with the School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798 (e-mail: shilin.shan@ntu.edu.sg; jianfei.yang@ntu.edu.sg).

(Corresponding author: Feng Xu, Jianfei Yang.) how to learn heartbeat observability from acquired signals and use the resulting score to select reliable measurements for different heart-rate estimators.

The need for measurement-level assessment has a physical basis. Echoes from multiple body-surface scatterers superpose coherently within the same range bin [13], [15]. Sub-wavelength differences in scatterer ranges alter their phase differences and can preserve or suppress the heartbeat component even under similar motion projections (Sec. III-B). Controlled simulations show markedly different heartbeat spectra at adjacent observation locations (Fig. 1a), consistent with location sensitivity reported in real measurements [14], [20]. Perturbing only scatterer phases also changes observability while macroscopic geometry remains fixed (Sec. V-A). Small body motions can introduce such phase changes over time. Favorable geometry therefore provides a useful prior, but the readability realized in each measurement must be assessed from the acquired signal.

Learning this assessment requires supervision across conditions in which the heartbeat component is preserved or obscured. Controlled acquisition of such observations is difficult because physiological motion varies across real recordings. We develop a multi-scatterer frequency-modulated continuous-wave (FMCW) simulator that generates paired observations under identical respiratory and heartbeat motion while varying observation geometry and scattering conditions. For each simulated spectrum, agreement between its dominant heartbeat-band peak and the known heart rate provides an automatic label of heartbeat readability. This supports learning a task-specific quality score from controlled measurements. A central challenge is whether a score learned from these simulated observations remains useful on real recordings acquired under different conditions. Prior work on cross-domain Wi-Fi gesture recognition demonstrates the value of physically motivated representations [23]. This motivates incorporating physiological frequency relationships into our spectral representation.

We address this challenge with HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer trained entirely on simulated observations. Its input combines spectral magnitudes with frequencies expressed relative to the respiration fundamental, providing context for respiratory harmonics that may resemble heartbeat peaks. A single forward pass produces an observability score and a heart-rate estimate, and the score supports selective prediction with either HEAR's own head or an external estimator. We evaluate transfer without real-data adaptation on two public datasets collected at 60 and 120 GHz from 134 subjects. At 50% coverage, selection reduces the HR head's MAE on the 120 GHz dataset from 17.9 to 1.6 BPM. The same score also improves selective estimation with multiple existing heart-rate estimators. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device.

The main contributions are as follows.

  1. Physical basis for observability assessment. We show that coherent superposition of scatterer returns can change the heartbeat phase response under fixed motion projections. This finding establishes why macroscopic geometry alone is insufficient to determine heartbeat readability and motivates assessment from each acquired measurement.

  2. Controlled simulation for observability learning. We develop a multi-scatterer FMCW simulator that generates paired observations under identical respiratory and heartbeat motion across radar positions. The framework supports controlled analysis of phase-superposition effects and automatically derives spectral-readability labels, providing supervision across diverse observation conditions.

  3. Transferable observability assessment. We propose HEAR, a compact dual-task network that jointly predicts heartbeat observability and heart rate using spectral features with respiratory-harmonic context. Trained solely on simulated observations, HEAR transfers zero-shot to two real datasets. The same learned score supports selective prediction with both HEAR and multiple existing estimators, enabling an accuracy–coverage trade-off.

The rest of the paper is organized as follows. Sec. II reviews related work, Sec. III presents the proposed method, Sec. IV describes the experimental protocol, Sec. V presents the results, Sec. VI discusses limitations, and Sec. VII concludes the paper. The appendices provide additional implementation details, dataset descriptions, the segmentation protocol for zero-shot evaluation, and an analysis of segment-hop sensitivity.