Abstract

Cardiovascular magnetic resonance (CMR), including cine imaging, is a reference standard for the noninvasive assessment of cardiac morphology and ventricular function. Cine CMR interpretation integrates qualitative visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion. Current medical vision-language models (VLMs) cannot reliably derive quantitative measurements from multidimensional cine images without analysis tools. We present CineMR, a tool-augmented VLM that invokes cardiac image-analysis tools and integrates their outputs into interleaved reasoning for quantitative CMR assessment. We also construct a multi-cohort visual question answering benchmark covering quantitative metric extraction, multiclass diagnosis, and differential diagnosis, together with tools for segmentation, phase selection, volumetry, morphometry, and regional wall motion analysis. CineMR is trained with supervised fine-tuning (SFT) on tool-interaction traces followed by Group Relative Policy Optimization (GRPO) with conditional tool-use rewards. On the multi-cohort cine CMR benchmark, CineMR achieves 35.9% pass@1 and 58.9% pass@4, compared with 1.5% pass@1 for the Qwen3-VL-8B backbone and 0.0% and 7.0% pass@1 for LLaVA-Med v1.5 and MedGemma-4B, respectively. Correct tool invocation reaches 99.8% after GRPO, up from 78.9% after SFT. Live tool outputs improve ventricular measurement accuracy by 20.4–23.7% over direct model predictions, and removing all tools reduces pass@1 from 35.9% to 27.9%. These results highlight the importance of reliable tool use for quantitative cine CMR reasoning and support CineMR as a promising approach for assistive cardiac image assessment. Code, benchmark resources, and model weights are available at https://github.com/AI-MIND-Lab/CineMR.

1 Introduction

Cardiovascular magnetic resonance (CMR) is a reference standard for the noninvasive quantification of ventricular volumes, myocardial mass, and systolic function [Petersen et al., 2016, Schulz-Menger et al., 2020]. Clinical CMR interpretation integrates visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion, together with clinical history and complementary imaging findings [Arbelo et al., 2023, Schulz-Menger et al., 2020]. Quantitative criteria can support phenotype classification, but definitive diagnosis may also require clinical, electrocardiographic, genetic, coronary, and tissue-characterization information. The combination of multidimensional image analysis, quantitative measurement, and criterion-based interpretation makes CMR a compelling testbed for tool-augmented

Preprint. † Equal contribution. § Corresponding authors.

Figure

Figure 1: Comparison of model outputs for the same cine CMR case, where the benchmark reference category is dilated cardiomyopathy (DCM). In this illustrative example, LLaVA-Med fails to provide a definitive assessment, whereas MedGemma produces unsupported tool-call content and repetitive text. In contrast, CineMR invokes executable tools to obtain quantitative measurements and evaluates them according to criteria encoded in the study-specific Rule-Based Cardiac Phenotype Classifier, thereby producing a traceable output grounded in explicit measurements and decision rules.

multimodal reasoning. This is particularly important because errors in upstream measurements can propagate to downstream classifications.

Recent medical VLMs have expanded multimodal question answering and generated-rationale capabilities, with reinforcement learning to optimize structured response generation [Lai et al., 2025, Pan et al., 2025, Su et al., 2025, Li et al., 2023, Sun et al., 2025]. However, general-purpose medical VLMs are not designed to perform the multidimensional image analysis required to derive quantitative CMR measurements reliably. As illustrated in Fig. 1, the evaluated baseline models may fail to produce a definitive assessment or generate repetitive text, unsupported tool outputs, or ungrounded quantitative values when prompted to interpret cine CMR. This limitation reflects the explicit multidimensional computations required for quantitative CMR assessment. For example, assessment of a DCM-compatible phenotype requires delineation of the left ventricle across multiple slices and cardiac phases, voxel-based calculation of ventricular volumes and ejection fraction, and interpretation using reference ranges and study criteria [Petersen et al., 2017]. Current VLMs cannot be assumed to reproduce this multistep quantitative pipeline reliably from image inputs alone.

Tool-augmented medical agents [Li et al., 2024, Fathi et al., 2025, Wang et al., 2026, Jiang et al., 2025] offer a promising direction, although many existing systems emphasize perceptual operations, such as segmentation visualization and region enlargement, rather than the explicit computation of clinically interpretable imaging measurements. Quantitative descriptors such as the septal-to-lateral wall-thickness ratio and mass-to-volume ratio may contribute to differentiating hypertrophic cardiomyopathy (HCM) from hypertensive heart disease (HHD), but they must be interpreted with additional morphological and clinical information; assessment of a DCM-compatible phenotype incorporates ventricular dilation and systolic dysfunction relative to appropriate sex-specific reference ranges [Petersen et al., 2017]. These measurements cannot be quantified reliably through visual inspection alone. These tasks require quantitative measurement in addition to visual interpretation, motivating tools that return explicit quantitative outputs. CineMR addresses this need by equipping a VLM with cardiac image-analysis tools and training it to invoke and integrate their outputs within an interleaved reasoning process.

Rule-Based Cardiac Phenotype Classifier-structured dataset. To make the supervision clinically traceable and systematically cover criterion-based reasoning, we organize the benchmark around a Rule-Based Cardiac Phenotype Classifier rather than relying only on direct image-to-label associations. The Rule-Based Cardiac Phenotype Classifier provides explicit diagnostic pathways linking quantitative measurements to reference answers and expected tool use. We derive the training data from a study-specific Rule-Based Cardiac Phenotype Classifier informed by published cardiomyopathy criteria, CMR reference studies, and explicitly documented project-specific thresholds [Arbelo et al., 2023, Petersen et al., 2017]. The Rule-Based Cardiac Phenotype Classifier covers ten harmonized outcome categories. Each question maps to a Rule-Based Cardiac Phenotype Classifier node annotated with its task-complexity level (L1–L6) and the tools expected to generate the reference answer. This structure encourages the model to follow criterion-based pathways and provides traceable supervision for both answer generation and tool use.

References (35)