Abstract—Autonomous colonoscopic navigation can reduce operator burden and the risk of loop formation or tissue trauma, but remains challenging due to deformable anatomy, weak-texture and specular endoscopic visuals, and contact-rich viscoelastic interactions. Existing methods either rely on geometry-driven pipelines, which are efficient and interpretable yet brittle due to manually engineered features and switching logic, or adopt learning-based policies, whose inferred depth/geometry can become temporally inconsistent or overly smooth under weak texture and specular highlights while simulation-trained variants (e.g., deep reinforcement learning) may further suffer from a sim-to-real gap. We propose ColoACT, an autonomous navigation system that integrates an RGB-D-E based Action Chunking Transformer policy (ColoACT policy) for a compact self-propelled Bevel-Gear-Based Endoscopic Robot (BGER). The ColoACT policy augments RGB with estimated relative depth and a gradient-based pseudo-elevation map to enhance fold-ridge saliency and other high-frequency geometric cues, and enables smooth continuous control of the BGER by predicting overlapping action chunks and fusing them via temporal ensembling. In different ex-vivo porcine colons (approximately 60 cm), our system achieves success rates of 85.4% and 72.5% in straight and curved segments, respectively, and achieves 70% success in 90-degree turns and 60% in double-bend sequences, with feasibility further demonstrated in challenging triple-bend segments. The project page is available at: https://Adamhu1.github.io/ColoACT/.

I. INTRODUCTION

Endoscopic examination remains the gold standard for the prevention and early diagnosis of colorectal diseases [1]. While traditional colonoscopy is widely adopted, it still suffers from a steep learning curve, limited automation, and risks of loop formation or tissue trauma during navigation [2]. Robotic endoscopic systems are therefore being explored to improve navigational safety and consistency [3], and to reduce the cognitive and physical burden on physicians.

Autonomous colonoscopic navigation is challenging due to large anatomical variability with frequent bends and collapses [4], weak texture and specular highlights, and strongly nonlinear, time-varying interactions [5] between the endoscope and viscoelastic tissue [6]. These factors demand a closed-loop policy that is robust under imperfect perception and contact disturbances while producing smooth, stable motion. Existing robotic navigation solutions fall into geometry-driven pipelines [7]–[9] and learning-based approaches [10]–[12]. Geometry-driven methods are often efficient and interpretable, but their reliance on manually engineered features and switching logic can make the behavior brittle under challenging visual conditions and contact-rich interactions. Learning-based strategies derive policies directly from data and can handle nonlinear dynamics. However, they remain limited by unreliable geometric cues under weak-texture/specular observations [13], where learned depth/geometry can be temporally inconsistent or overly smooth and obscure fine topographic structures [14], and by sim-to-real gaps in simulation-trained variants (e.g., reinforcement learning) due to difficulty of faithfully modeling viscoelastic, contact-rich colon interactions [15], [16].

To address the challenges of robustness under weak-texture conditions, smooth control consistency, and the sim-to-real gap, we propose ColoACT, a holistic navigation system that integrates an RGB-D-E input that combines appearance (RGB) and geometry (RGB with estimated relative depth and a gradient-based pseudo-elevation map) based Action Chunking Transformer (ACT) policy for smooth, continuous closed-loop control and a compact self-propelled Bevel-Gear-Based Endoscopic Robot (BGER) designed to provide the mechanical and visual stability required by learning-based navigation. To the best of our knowledge, we present the first imitation-learning-based navigation policy for a self-propelled colonoscopic robot in ex-vivo tests. We validate the full system in ex-vivo porcine colons, achieving success rates of 85.4% in straight and 72.5% in curved segments ( ∼\sim60 cm). The system further succeeds in highly tortuous anatomies, successfully negotiating sharp 90-degree turns (70%) and double-bend paths (60%), and remains feasible even in extreme triple-bend scenarios. The contributions of this work are as follows:

This work is supported by the National Key Technologies R&D Program of China (Grant No. 2023YFC2415900), the National Natural Science Foundation of China (No. 62373182). This work is partly supported by the Shenzhen Science and Technology Program (Grant No. JCYJ20241202125417024), and Guangdong Basic and Applied Basic Research Foundation (Grant No. 2024A1515011915). The authors acknowledge the assistance of SUSTech Core Research Facilities.

J. Hu, S. He, Z. Li, D. Huang and C. Hu are with the Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China. (Corresponding email: hucz@sustech.edu.cn)

  1. We proposed an RGB-D-E ACT navigation policy (ColoACT Policy) that leverages multi-cue geometric representations to improve robustness in challenging colonic environments, while generating smooth and stable actions.

L. Chang is with the School of Mechanical Engineering and ZJU-UIUC Institute, Zhejiang University, Zhejiang, China

  1. We design a compact self-propelled BGER mechanism

C. Shi is with the School of Mechanical Engineering, Tianjin University, Tianjin, 300072, China.

Figure

Fig. 1. System Overview of the proposed ColoACT for Autonomous Navigation of the Bevel-Gear-Based Endoscopic Robot. (a) Framework Overview: The framework integrates a multi-cue perception module (RGB, relative depth, and pseudo-elevation, RGB-D-E) with an ACT-based control policy. Left: ot=[Itrgb,Dt,Et]\mathbf{o}_t = [I_t^{\mathrm{rgb}}, D_t, E_t] is formed using Depth Anything V2-Base for relative depth and Scharr gradients for pseudo-elevation. Right: The policy predicts an action chunk at:t+k−1\mathbf{a}_{t:t+k-1}, which is synthesized via Temporal Ensembling to generate smooth actuation commands at\mathbf{a}_t ( vt,ωtv_t, \omega_t). ( vt,ωtv_t, \omega_t) represents the normalized linear velocity and angular velocity. (b) The actual navigation of the BGER in the porcine colon. (c) The assembled BGER, with dimensions of 24×20×3424 \times 20 \times 34 mm. (d) The overall design of the BGER. (e) Transmission System Design of the BGER.

that ensures transmission stability and supports reliable visual feedback for autonomous control.

  1. We demonstrate system-level validation of ColoACT on ex-vivo porcine colons, showing strong performance across straight, curved, and complex tortuous segments.

References (30)