arXiv:2610.01358q-bio.BMOct 2026

Manuscript Offprint

arXiv:2610.01358

Fold'EM: Direct atomic structure inference from Cryo-EM particles

Advaith Maddipatla, Märt-Erik Mäeots, Marco Pegoraro, Nikolaus Dräger, Roberto Covino, Sanketh Vedula, Martin Pacesa, Alex M. Bronstein

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Single-particle cryo-electron microscopy (cryo-EM) has become a widely adopted technique for biomolecular structure determination. The conventional cryo-EM computational pipeline first combines many particle images to reconstruct an electrostatic potential (ESP) map and then fits an atomic model to the recovered map. Density reconstruction has high sample complexity, requiring large numbers of particle images and making structure determination high-cost and low-throughput, particularly for structurally heterogeneous samples. Downstream atomic model building, in turn, becomes increasingly difficult as the resolution of the reconstructed map deteriorates. Protein structure prediction models provide strong sequence-derived priors on atomic structure, and experiment-guided approaches can use these priors to recover structures consistent with experimental measurements. Yet, in cryo-EM, such priors are typically integrated only after density reconstruction during atomic model fitting. We introduce Fold'EM, an inference-time framework that combines priors from protein structure generative models directly with cryo-EM particle images to determine atomic models from a small number of single particle images, bypassing both intermediate density reconstruction and downstream model building against the reconstructed map. Across synthetic benchmarks and experimental cryo-EM data, Fold'EM recovers accurate atomic structures both with known particle orientations and in an ab initio setting where orientations are inferred jointly with structure. In heterogeneous datasets, Fold'EM further resolves distinct conformational states from mixed particle populations without separately reconstructing a density map and building an atomic model for each state. We believe these results open new avenues for structure determination in the low-sample regime and for characterizing low-population conformational states directly from cryo-EM particles.

1 Introduction

Single-particle cryo-electron microscopy (cryo-EM) has transformed structural biology by enabling high-resolution structure determination of large macromolecular assemblies without crystallization (Fernandez-Leiro and Scheres, 2016). Its ability to image individual molecules in different conformations also provides a route to understanding how structural changes drive biological function (Ourmazd, 2019; Mäeots and Enchev, 2022). Yet the fundamental measurement is extremely noisy. Radiation damage limits the electron dose that can be applied to each particle, leaving individual images unsuitable for direct structural interpretation and requiring large numbers of observations to be aligned and combined into a three-dimensional electrostatic potential (ESP) map (Scheres, 2012; Kimanius et al., 2024). The resulting density must then be interpreted as an atomic model, a step that can remain difficult despite advances in automated model building, particularly where local resolution is poor (Jamali et al., 2024; Fadini et al., 2026).

∗^{*}Equally contributing first authors. †^{\dagger}Equally contributing senior authors.

The demand for coherent averaging creates a tension between spatial resolution and biological completeness. Combining particles from different conformations blurs structural features, whereas separating them into increasingly homogeneous populations leaves fewer observations available for each state (Frank and Ourmazd, 2016). Low-population and transient states are especially difficult because they may be merged with more abundant conformations, excluded during particle selection, or remain too sparsely represented for independent reconstruction. For scarce samples or proteins that cannot be obtained in sufficient quantity, the observations required to reconstruct each state may simply not be available.

Heterogeneity modeling can recover conformational variability beyond a small set of discrete structural classes (Frank and Ourmazd, 2016; Zhong et al., 2021; Gilles and Singer, 2025). However, these approaches generally require prior particle orientations, and thus remain dependent on upstream particle selection and alignment. Improving heterogeneous reconstruction therefore addresses only part of the difficulty of obtaining mechanistic information from sparse, noisy observations, while leaving unresolved the fundamental requirement for large numbers of particles.

Conventional single-particle cryo-EM reconstruction pipelines primarily estimate densities from image measurements, making limited use of prior knowledge about protein structures in general, or the sequence of the sample under study. Blush regularization in RELION demonstrates the value of incorporating such knowledge by using a denoiser trained on experimental cryo-EM maps to provide richer regularization than a generic smoothness prior, improving reconstruction when particle signals are weak (Kimanius et al., 2024).

AlphaFold and related prediction models encode knowledge of sequence-dependent folds and interactions learned from evolutionary and structural data, providing strong sequence-conditioned structural priors (Jumper et al., 2021; Baek et al., 2021). Building on these priors, a recent line of work has shown that experimental guidance can steer these models toward conformations consistent with the experimental data but missed by unconditioned predictions (Maddipatla et al., 2025; 2026b; Fadini et al., 2026; Raghu et al., 2026). In cryo-EM, however, these approaches have focused on reconstructed maps, applying structural knowledge after particle selection, alignment, and averaging have already taken place. They therefore inherit the need for sufficiently many particles to support reliable reconstruction. In this work, we ask: can structural priors be introduced directly at the particle level, enabling atomic inference from sparse cryo-EM observations without requiring a high-resolution intermediate reconstruction?

References (40)