VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC-Metal Benchmark

Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique

Amritesh Banerjee*, Abdul Basit†, Renil Renji Joseph‡, Nouhaila Innan†§, Muhammad Shafique†

*University of Massachusetts at Amherst, Amherst, USA

†^{\dagger}eBRAIN Lab, Division of Engineering, New York University Abu Dhabi (NYUAD), Abu Dhabi, UAE

‡^{\ddagger}Indian Institute of Technology Delhi Abu Dhabi, UAE

§Center for Quantum and Topological Systems (CQTS), NYUAD Research Institute, NYUAD, Abu Dhabi, UAE amriteshbane@umass.edu, renilrenijjm@gmail.com, {abdul.basit, nouhaila.innan, muhammad.shafique}@nyu.edu

Abstract—Metal artifacts in postoperative musculoskeletal CT obscure bone–implant and adjacent soft-tissue interfaces. Many metal artifact reduction (MAR) methods require unavailable raw projections or learned models that may shift across scanners and implants. We present VoxelSynth3D, a training-free 3D image-domain framework for reconstructed CT. The framework combines support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only. The operating point was fixed in a near-flat validation basin. With exact-mask oracle localization, all methods share a metal-excluded tissue ROI. On 40 held-out cases, VoxelSynth3D reduced RMSE from 801.48 to 786.18 HU (paired gain 15.30 HU, 95% CI 11.68–19.23), improving every case and exceeding the evaluated 3D Gaussian smoother by 13.58 HU. Clean-edge agreement decreased next to metal but exceeded input beyond 5 mm. Thus, VoxelSynth3D provides case-consistent within-distribution tissue-error reduction with a localized structural tradeoff. Spacing-aware sensitivity retained aggregate broad-region improvement and identified near-metal calibration as a target.

Index Terms—computed tomography, metal artifact reduction, volumetric image processing, controlled synthetic evaluation, CTPelvic1K, medical image reconstruction

I. INTRODUCTION

Computed tomography (CT) is indispensable for postoperative musculoskeletal assessment because it visualizes implant placement, osseointegration, loosening, infection, fracture fixation, and periprosthetic complications. The same hardware also corrupts CT: beam hardening, scatter, and photon starvation produce streaks and dark bands that obscure bone–implant and soft-tissue interfaces [1], [2]. As orthopedic hardware becomes more prevalent [3], [4], metal artifact reduction (MAR) is a practical requirement for reliable interpretation.

Classical projection-domain methods, including linear interpolation (LI) and normalized MAR (NMAR), are deterministic and physically motivated, but their strongest form assumes raw or scanner-consistent projection data [2], [5], [6]. This assumption is restrictive for retrospective studies, public CT repositories, and multi-institutional datasets where only reconstructed volumes are available. Learning-based MAR, including image-domain CNNs and dual-domain models such as DuDoNet and InDuDoNet, can model nonlinear artifacts when training and deployment conditions match [7]–[10]. However, these methods depend on training data, acquisition geometry, reconstruction kernels, and synthetic-to-clinical transfer. Reconstructed-volume CT therefore needs MAR methods that are volumetric, localized, interpretable, and evaluable without unavailable raw projections or opaque learned behavior.

VoxelSynth3D addresses this gap as a deterministic 3D image-domain framework. Correction is restricted to an implant-adaptive artifact support, where a normalized volumetric tissue prior estimates plausible non-metal attenuation, a deviation gate limits replacement to corrupted voxels, and restricted edge-guided refinement reinjects high-frequency structure only where support and gradients indicate softened anatomy. This design targets the central MAR tradeoff: suppressing streak and dark-band energy while limiting changes to unaffected tissue. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. The novelty is system-level: established operators are composed in an implant-adaptive 3D correction whose support, prior, and weights are inspectable, rather than proposed as new filtering primitives.

Evaluation is also difficult because real metal CT rarely has paired clean reconstructions. We therefore construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource. This synthetic dataset is generated from no-metal CTPelvic1K pelvic CT volumes [11], retaining clean targets, corrupted volumes, metal masks, artifact-ROI masks, spacing metadata, and patient-level splits. This enables within-distribution full-reference evaluation on synthetic cases while keeping real CLINIC-metal scans separate for qualitative and no-reference validation. Full-reference evaluation uses one fixed surrounding-tissue ROI after excluding the inserted core. Pseudo-sinogram baselines are included for comparison, but are interpreted as approximate image-domain adaptations rather than scanner-native projection MAR. Learned rows are likewise public-checkpoint transfer tests, not controlled in-

Proposed VoxelSynth3D Pipeline

Localized correction inside implant-adaptive support

Figure

Fig. 1: Workflow overview and visual intuition for the proposed VoxelSynth3D pipeline. The method operates directly on reconstructed CT volumes without raw projection data, estimates an implant-adaptive support, synthesizes a normalized non-metal tissue prior, applies deviation-gated local blending, and restricts edge-guided refinement to the artifact support. The component ablation path reports how each design element contributes to the final edge-guided configuration. Detected metal is retained in the reported output.

domain comparisons.

This paper makes four contributions:

• Volumetric MAR: adaptive support, normalized tissue synthesis, gated blending, and restricted edge refinement for reconstructed CT.

• Controlled paired resource: Synthetic CLINIC-Metal with clean targets, masks, spacing, patient-level splits, and a metal-excluded tissue endpoint.

• Comparative evaluation: image-domain filters, pseudo LI/NMAR, learned MAR checkpoint-transfer tests, and component ablations.

• Conservative protocol: validation sensitivity, CIs, paired tests, severity, and real no-reference analysis, plus distance, edge, mask, and external stress tests.

On 40 held-out synthetic cases, VoxelSynth3D achieved lower metal-excluded tissue RMSE and higher ROI MSE reduction than the input and evaluated 3D Gaussian smoother, while learned baselines retained higher edge preservation or tissue SSIM in some settings. The effect was case-consistent: every case improved, while clean-target analysis found a true-edge cost immediately next to metal. The claim is therefore within-distribution artifact suppression with a localized structural tradeoff, not anatomical recovery. We do not claim scanner-native projection-domain superiority; instead, we target retrospective settings where only reconstructed CT is available. Figure 1 illustrates the VoxelSynth3D pipeline.