arXiv:2610.01956cs.CVOct 2026

Manuscript Offprint

arXiv:2610.01956

EndoLive: Real-Time Style Transfer for Endoscopic Endonasal Skull Base Surgical Video

Griffin Hurt, Calvin Brinkman

Hurt, Griffin

University of Pittsburgh

School of Computing and Information

griffhurt@pitt.edu

Brinkman, Calvin

University of Pittsburgh

School of Computing and Information

cbrinkman@pitt.edu

Figure

Figure 1. EndoLive in action. Generated image pairs from the output of EndoLive. In each pair, the left image is a cadaveric image from our test dataset and the right image is the enhanced image produced in real-time by our model. The left pair of images demonstrates the capability of our model to generate fake blood in the visible field, a commonly described limitation of cadaveric models [20]. The right pair of images demonstrates the capability of the model to semantically understand anatomical landmarks that appear similar in color in both live and cadaveric images. In this case, the pituitary gland is colored similarly between the original cadaveric frame and the generated image.

Abstract

Complex surgical procedures around critical anatomy, such as the endoscopic endonasal skull base surgery, requires significant practice and training on the part of the surgeon before they are allowed to perform the operation on a live patient. This training in typically done in cadaveric specimens, due to them containing the same critical structures as a living human. However, cadavers are not a perfect 1-to-1 substitute for a living patient. The dead and preserved tissues of a cadaver are colored completely differently than a living human, and – without complex and expensive pumping systems – do not bleed in the same way. As a result, identifying the critical pieces of anatomy that make this procedure so complex can be quite different in a live case than in a surgeon's cadaveric practice. This paper presents EndoLive, a framework for real-time style transfer between cadaveric endoscopic video and living human endoscopic video. Our method combines the Con-

StructS GAN model for realistic style transfer for surgical applications, with the HyPER-GAN model that can learn complex translations and perform them in real-time. We train EndoLive on unpaired cadaveric and live images taken from an endoscope, and test the trained model with cadaveric video, on a variety of devices. Experimental results demonstrate that EndoLive can perform cadaveric-to-live translation at speeds well above the minimum necessary for real-time, while maintaining semantic consistency of critical anatomical structures. Our source code is available at https://github.com/griffhurt/endolive.

1. Introduction

Endoscopic endonasal skull base (EESB) surgery is a novel form of neurological surgery that enables access to complex anatomy via an endoscope inserted into the nasal cavity [10]. This type of surgical procedure is used in a variety of neurological pathologies, including pituitary ade-nomas, craniopharyngiomas, and cerebral spinal fluid leaks (CSF leaks) [10]. Before the advent of skull base surgery, these diseases were treated with transcranial approaches that required long operative times [10]. However, in the late 1990s, two different independent research groups at University of Pittsburgh began pioneering a treatment mechanism that used novel endoscopic technology based on the prior work of ear, nose, and throat physicians [16]. Over the last 25 years, the technique has been further developed and is now a somewhat common practice in neurological surgery.

Due to the complexity of the procedure, surgeons wishing to specialize in this particular surgical style must spend a significant amount of time training for the approach. Some surgeons spend up to 9 years after medical school practicing the skull base approach before they are able to perform the procedure independently [9]. The apprenticeship model for teaching new medical school graduates to become independent surgeons practicing the EESB approach results in a wide variance of mechanisms used in teaching and learning. James et al. reported that most hands-on training for the procedure occurs in an operative setting under the guidance of senior surgeons, an undeniably higher-risk approach compared to training in models [11]. This is in line with the classical “Halstedian Preceptorship” model used for teaching surgery, characterized with the aphorism “see one, do one, teach one” [14]. However, when models are used for training EESB surgery, the broader literature suggests that cadaveric dissection models are the most common teaching tool employed [11].

Cadaveric models are widely employed as a training simulation for surgical residency programs across a range of specialties, including spine surgery [8], urology [1], and orthopedic surgery [23]. While cadaveric models provide an accurate estimation of gross anatomy and allow surgeons to develop additional spatial reasoning skills, several limitations exist, including the absence of active bleeding, absence of breathing perception, and the malodorous nature of cadaveric models [20]. Prior work has attempted to improve upon the realism of cadaveric models by perfusing blood through fresh cadavers [4]; however, this incurs a large cost in addition to the already high cost of cadaveric models.

Recent improvements in machine learning have opened the door for image generation models to create images from various other information modalities, including text and other images [7]. Within the context of neural image generation, style transfer has become a common application. Style transfer is the process of changing the style of a given image without changing its underlying content [12]. Style transfer has been used for a variety of purposes, both creative and technical, and executed with a variety of methods like diffusion models [25] and GANs [6, 21]. Within the context of cadaveric models, style transfer can be used to eliminate limitations like poor coloration or lack of the appearance of blood by changing cadaveric video from an endoscope to appear like videos of live surgery. We call this process “cadaveric to real style transfer” or “CaRST”.

A nascent research area of EESB surgery that is gaining popularity is the integration of spatial computing technologies like augmented and mixed reality. Given the endoscopic nature of EESB, surgeons spend most of the case attending to several monitors throughout the operating room. Due to the sterility constraints of the operating room, surgeons are unable to adjust or otherwise manipulate the physical monitors surrounding the surgical field. This leads to communication overhead in the operating room for monitor layout, as the surgeon must ask other members of the surgical team to position their displays, and decreases overall surgical ergonomics. Spatial computing allows information to lose its physical boundaries and be presented on virtual elements that exist solely within the displays of a head-mounted display (HMD). Thus, the surgeon can manipulate these virtual displays without breaking sterility and gain a greater agency over their visual field and decrease split attention. Several papers have investigated the use of spatial computing in EESB [2, 5, 15, 24], indicating its feasibility and benefits beyond traditional approaches. Using spatial computing to facilitate endoscopic surgery requires extremely low glass-to-glass latency [13], so integrating machine learning into these pipelines requires the models to have fast inference times and high frame rates to maintain standard of care.

In this work, we propose a dual-model approach for performing real-time endoscopic video style transfer from cadaveric based on ConStructS [22] and HyPER-GAN [17]. While neither of these models on their own can effectively perform CaRST in real-time, combining them together enables novel surgical training visualization. We investigate the accuracy and efficiency of this architecture both on dedicated hardware (two NVIDIA RTX A5000s with CUDA) and on a spatial computing device (M2 Apple Vision Pro with CoreML) to understand its applicability to existing clinical workflow.

References (24)