Abstract

When a SCADA alarm is raised in a water distribution network, operators must decide quickly whether it reflects a cyberattack, a physical fault, a normal transient or a faulty sensor. Supervised classifiers need labelled incidents that utilities rarely have, and frontier large language models (LLMs) take tens of seconds per decision. We tested whether Jev, a training-free model that returns class probabilities in about one second, can serve as the first tier of this triage. On a four-class cause-attribution benchmark built on the C-Town network in EPANET, Jev was compared with a hand-written rule tree, a supervised classifier and seven cloud LLMs on identical evidence in four sealed, pre-registered rounds. With only a label-free prior correction, Jev matched the rule tree (macro-F1 0.62-0.64 against 0.56-0.61 in distribution) and exceeded the supervised classifier by 0.36-0.42 on event subtypes absent from its labels, in all four rounds, and it outperformed the classifier whenever fewer than about four labelled events per class were available. Jev also decided 20-40 times faster than frontier LLMs. Accepting only benign Jev verdicts confirmed by the rule tree spared an LLM reviewer 35-38% of windows on fresh sealed sets without loss of macro-F1. Transferred unchanged to two further networks, this gated cascade stayed within the non-inferiority margin of its reviewer on all four sets. A fast, training-free screen can therefore take over about a third of the review load in SCADA anomaly triage while preserving the accuracy of deliberate review.

Keywords: Water distribution networks; Fault diagnosis; Cyber-physical security; Large language models; Training-free classification

Graphical abstract (TOC graphic)

HydroJEV

Fast screening before LLM review

Water-network anomaly attribution

SCADA + digital twin

C-Town simulation

R1 rule tree

Figure

Accepted predicted label

Normal transient /

Sensor fault

Jev screen

Fixed-choice judgment

Label-free prior correction

No task-specific training

LLM review

Four-class attribution

Cyberattack / Physical fault

Normal transient / Sensor fault

1.2 s

median service compute

4 sealed rounds · 1,279 simulated windows.

34.5–38.0%

LLM calls spared

69/200 and 76/200 windows

Non-inferior macro-F1

GLM-5.2 cascade vs reviewer alone

ΔF1+0.011/+0.016⋅margin 0.03\Delta F1 + 0.011 / +0.016 \cdot \text{margin } 0.03

TOC graphic. A one-second, training-free typed-judgment screen for anomaly cause attribution: it is fast, robust to event subtypes absent from supervised labels, and spares an LLM reviewer about a third of its calls without loss of accuracy; LLM review remains necessary for concealed attacks.

References (28)