Manuscript Offprint
arXiv:2608.21147Capturing Cardiac Cyclicity through Phase-Equivariant Self-Supervised Learning
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Blaise Delaney*
TimeTrace Labs
Dominic Dootson*
TimeTrace Labs
Andrew Pfaff
TimeTrace Labs
Juan Jose Juan Castella
TimeTrace Labs
University of Cambridge
Yuji Xing
TimeTrace Labs
Salil Patel
TimeTrace Labs
University of Oxford
Jonny Hancox
NVIDIA
Karin Sevegnani
NVIDIA
Abstract
The cyclic structure of physiological processes offers a natural prior for self-supervised representation learning, and the cardiac cycle provides a particularly well-defined setting in which to exploit it. We derive a phase-equivariant self-supervised objective and introduce WINDER, a joint-embedding architecture that organises representations into phase-invariant coordinates and phase-rotating harmonic subspaces. Its transport operator is fixed and closed-form, derived from the cycle’s geometry rather than learned, and adds no parameters. Evaluated on PTB-XL under a frozen linear-probe protocol, WINDER attains diagnostic accuracy within the range reported by state-of-the-art self-supervised methods at a 1 M parameter footprint, while exhibiting phase-equivariant latent geometry. These findings demonstrate that explicitly encoding cardiac-phase symmetry can preserve diagnostically useful information while yielding a latent geometry that is legible, parameter-efficient, and directly tied to a measurable physiological quantity.

Figure 1: Phase reparameterisation of the cardiac cycle. A heart beat between consecutive R peaks is mapped from linear time to phase . Identifying with makes the periodic structure of the heartbeat explicit while preserving within-cycle ordering.
1 Introduction
The 12-lead electrocardiogram (ECG) provides a rapid, non-invasive measurement of cardiac electrical activity at millisecond-scale resolution. Its interpretation depends on the morphology and timing of the P wave, QRS complex, T wave, and intervening intervals [1]. Despite variation in rate and morphology, cardiac electrical activity follows a recurrent sequence of depolarisation
Equal contribution; joint first authors.
and repolarisation [2]. Mapping successive R–R intervals onto a common phase coordinate preserves this ordering while normalising beat duration, a principle reflected in QT rate correction [3]. Conduction delay and ischaemic deformation can then be viewed as changes to within-cycle timing and morphology, while ectopic activity disrupts the recurring pattern across cycles.
Continuous physiological recordings capture both patient-state dynamics and sensor-level noise—motion, electrode contact, baseline wander—in a single observed trace. Scored in input space, autoregressive and reconstruction objectives are compelled to reward reproducing the sensor observation in full, noise included. Joint-embedding predictive architectures (JEPAs) offer an alternative prescription, whereby predictions are scored against a latent target, training an encoder–predictor system to anticipate a future or masked representation of the signal state rather than the raw sample [4, 5]. Under this paradigm, sensor variation need not be reproduced sample by sample; insofar as the target encoder suppresses variation unnecessary for predicting the latent signal state, representational capacity can concentrate on physiological dynamics.
Learning the heart’s recurring structure requires exactly this kind of objective: one that preserves cardiac-cycle timing and morphology without being dominated by nuisance signals. Pointwise reconstruction can overemphasise high-amplitude motion and channel artefacts; the corresponding advantage of latent prediction has been reported for ECG [6] and EEG [7]. The relaxation does not, however, confer invariance to artefacts: it withdraws the explicit reward for reproducing them without penalising their encoding. Standard latent-prediction objectives also leave the organisation of cardiac phase unspecified. A model may therefore encode phase without organising latent motion consistently across beats.
In this work, we introduce WINDER, a phase-equivariant extension of LeJEPA [8, 9]. WINDER retains LeJEPA's regularisation against representational collapse and adds a transport objective that penalises deviations from phase equivariance. This objective encourages latent trajectories to follow cardiac-phase order consistently across beats, grounding the representation in the heart's physiological cycle.
Empirically, enforcing this periodic symmetry improves diagnostic performance over a matched transport-free control. WINDER also attains performance in the same broad range as substantially larger self-supervised ECG models with only 1.2 M deployed parameters, while producing phase-ordered latent geometry.
The remainder of this paper is organised as follows. Next, the current state of the art of self-supervised learning, time-series representation learning, and equivariant deep learning is discussed. Inspired by these ideas, Section 3 derives the required loss function to enforce phase-equivariant representations. In Section 4, the implementation of WINDER in a compact causal architecture is described. Our experiments in Section 5 assess diagnostic performance, cardiac-phase equivariance, latent geometry, and the contribution of the transport objective. Finally, the implications and limitations of these findings are discussed in Section 6 before concluding in Section 7.
2.1 Predictive Self-Supervised Learning
A central challenge in self-supervised learning is preventing non-contrastive objectives from converging to uninformative representations. Recently, LeJEPA [8] prevented representation collapse by regularising the embedding distribution directly, rather than through heuristics such as stop-gradients or teacher–student networks [10].
LeJEPA pairs a predictive loss with the Sketched Isotropic Gaussian Regulariser (SIGReg), which tests Gaussian isotropy of the embedding distribution along randomly sampled projection directions
(1)
where is a univariate goodness-of-fit statistic applied to the projection of the latent embeddings, , along the unit vector, . To target an isotropic Gaussian distribution, the natural univariate test is the Epps–Pulley (EP) goodness-of-fit statistic [11]:
The empirical and standard Gaussian characteristic functions are defined as
Equation (1) replaces the maximum over projection directions in LeJEPA's theoretical criterion with an average, preventing the gradient from concentrating on only the worst-performing direction. Collapse is thus excluded by construction of the SIGReg regulariser rather than by tuning, leaving only a single trade-off hyperparameter that tunes the relative weight between regulariser and predictive loss. LeWorldModel [9] carries this recipe to the temporal setting: next-embedding prediction from pixels under the same SIGReg regularisation.
Since LeJEPA, the recipe’s every component has been revised in turn: the target geometry, rectified toward sparsity [12], or proven suboptimal to a uniform sphere on manifolds [13]; the test statistic [14]; and the constraint’s ambient scope, which Sub-JEPA restricts to random, deliberately frozen subspaces [15].
A parallel wave targets the marginal’s blindness to temporal order: SD-JEPA learns a progression coordinate [16]; letting one emerge from temporally centered residuals [17]; or pools the statistic within-sample across time [18]. Yet to our knowledge the regularised objective remains a set in every case, invariant to permuting the time index. The conditions under which the base recipe’s guarantees hold are only now being characterized, so far confined to a restricted world class of independent, Ornstein–Uhlenbeck latent dynamics under isotropic sampling [19].
SIGReg has recently entered biosignal representation learning, primarily through EEG and broader multi-domain time-series models [7, 20, 21]. Its application to ECG remains limited. LeNEPA regularises temporal embeddings within individual PTB-XL recordings [18], while Beyond Patient Invariance represents pathology as a transition in latent space and reports that SIGReg outperforms VICReg on physiological signals [22]. Neither method imposes a cardiac phase coordinate.
CardioState-JEPA is the closest phase-aware ECG method, but treats phase as an auxiliary supervised target within an objective that retains an EMA teacher [23]. Sonata models another periodic biosignal—gait and tremor dynamics—by expanding the recurrence eigenspectrum to support oscillatory modes [24, 25]. In both cases, cyclicity is predicted or accommodated rather than imposed as a symmetry of the latent space.
Other ECG self-supervised methods either pre-date SIGReg [6] or use world models for intervention simulation [26]. Moreover, a recent scaling study finds contrastive predictive coding modestly ahead of JEPA-style objectives at comparable scale [27]. Thus, neither the appropriate anti-collapse regulariser nor the correct representation of cardiac phase is settled. Section D places WINDER alongside these methods on PTB-XL, with their parameter counts and pre-training corpora, and sets out why no two published entries share an evaluation protocol.
2.2 Time-Series Foundation Models: Scale, Adaptation, and Efficiency
Outside this lineage, general-purpose time-series foundation models continue to diversify along three largely independent axes [28]: scale, in-context adaptation, and architectural efficiency. Pretraining now extends into wearable sensing at trillion-minute scale, with SensorFM's own scaling ablations spanning up to a hundred million parameters and transferring across dozens of downstream health tasks [29]. A parallel direction replaces retraining with adaptation at inference time: Baguan-TS conditions a sequence-native forecaster on a retrieved, covariate-aware context rather than updating any weight [30]. At the other end of the spectrum, with only 0.2M–2.6M parameters, Reverso [31] closes much of the performance gap to models one to three orders of magnitude larger. It does this through a hybrid architecture alternating gated long convolutions with DeltaNet's linear-recurrent state updates. WINDER sits at a similar scale to Reversoby imposing structure on the latent space rather than architecturally innovations.
Two related time-series architectures, Olivia and RoMAE, also apply rotations to continuous coordinates, but toward different ends than WINDER. Olivia harmonises cross-domain spectral heterogeneity by learning an orthogonal transform of the raw time axis, parameterised, as here (Equation (12)), as a product of Householder reflections [32]; RoMAE instead fixes the rotation, applying rotary position embeddings to continuous positions within a masked-autoencoder objective [33]. In both cases the rotated coordinate is domain-agnostic — dataset identity or sequence position — and the rotation removes or encodes a nuisance; WINDER's rotation instead acts on a single physiologically derived coordinate, cardiac phase, to impose a symmetry the latent representation is required to respect.
2.3 Equivariant Representation Learning for Time Series
Equivariant networks encode a known symmetry as a group action the model is constrained to respect: transforming the input by g transforms the representation by a corresponding . The canonical construction is group-equivariant convolution [34]; Bronstein et al. [35] place this construction in the geometric deep learning catalogue of grids, groups, graphs, geodesics, and gauges. Two symmetries spring to mind for time series: time-translation (sliding the window) and dilation (changing sampling rate). Both have been realised as group-equivariant layers [36, 37], including sampling-rate and discrete-scale forms [38, 39]. A time shift and a phase advance are not, however, the symmetry that defines cardiac cycle: phase is periodic in the beat, not a shift or a stretch of the recording.
The constructions above constrain the geometry of the input: the layer is built so that a transformation of x is matched by a transformation of the features. A second literature constrains the geometry of the latent space instead, requiring z itself to transform under G. A disentangled representation is defined as a split of z into an invariant factor and a factor that transforms with the group [40]. Unsupervised group-equivariant autoencoders learn that split from a known action on the input, producing invariant and equivariant latent coordinates [41]. Class-pose decomposition writes z as an invariant class code times a group element [42]. The same move appears outside vision: POEM rotates paired latent features of a time-series forecaster by a learned phase under periodicity drift [43], and PHALAR realises time-shift as a rotation via the Fourier shift theorem, in audio [44]. These methods show that a group action can be imposed on z, but they are developed for images, objects, generic time series, and audio, not for healthcare.
On ECG, physically grounded latent geometry exists without a group action. LVCG maps 12-lead recordings to a latent Frank vectorcardiogram and trains view-invariant tokens; R-peaks segment beats, but they are not used as a symmetry [45]. Nef-Net queries an implicit electrocardiac field by viewpoint angle to synthesise new leads [46]. In both cases the geometry is of the source as seen from different electrodes. Invariance to view is not equivariance to cardiac phase: transforming the input should move z in a controlled way, not leave it fixed.
Similar approaches appear in health, but none have imposed phase equivariance on a learned ECG representation. CatEquiv uses circular 1-D convolution so that rolling an inertial window is equivariant by construction [47]: that is a cyclic shift of the recording, not a phase advance through a physiological cycle. Echo-POSED is equivariant to probe pose and invariant to cardiac phase, so the representation does not track left-ventricular twist [48]. This phase invariance inverts the constraint required here.
To our knowledge, a derived cardiac-phase action on a learned ECG latent remains unoccupied. This work fills this gap.
3 Theory
The recurring physiological organisation of the cardiac cycle motivates treating phase not merely as a timestamp, but as a symmetry that the latent representation should preserve. Given this observation, instead of parameterising the heartbeat as a function of time, , it can be reparameterised as a function of phase, , representing the closed-loop cardiac cycle.
Given detected R-peak timestamps , the phase map is defined by
This reparameterisation introduces the phase-translation group , which is isomorphic to . Let denote a space of phase-parameterised multivariate time series on which acts — in this work a 12-lead ECG signal. For , the action on is defined by
This definition corresponds to the canonical left action of shifting functions along the circular domain. The central idea of WINDER is simple: the latent space should obey the same symmetry as the cardiac cycle. The following derivation establishes the equivariance condition required for the latent representation to satisfy the periodic symmetry.
3.1 Phase-Equivariant Latent Space
To model latent evolution over cardiac phase, the encoder is required to preserve the phase-translation symmetry of the input. Specifically, the action on the input space should induce a corresponding action on the latent space , such that
Thus, translating a signal in phase before encoding is equivalent to translating its latent representation after encoding (see Figure 2).

Figure 2: Commutative diagram of phase equivariance. Encoding after a phase translation is equivalent to applying the corresponding latent transformation after encoding, .
The natural building blocks of the latent group symmetry are the irreducible representations (irreps) of the underlying group, . For convenience, the analysis uses real representations.
Under the isomorphism , each conjugate pair of non-trivial complex characters is represented by a two-dimensional real rotation block. The real irreducible representations are of two types:
Imposing -periodicity, , gives
The zero-frequency character is trivial. Over , the characters and form equivalent two-dimensional rotation representations, so only the canonical representatives are retained.
Because is compact, averaging an inner product over the group yields an invariant inner product. Consequently, every finite-dimensional continuous real representation is equivalent, after a change of basis, to an orthogonal representation. Because the encoder's latent coordinates are learned, their axes need not align with the invariant subspaces on which the irreducible representations act. An orthogonal change of basis is therefore introduced, with expressing the learned latent in the canonical irrep basis.
In this canonical basis, the group action decomposes into a trivial component and harmonic isotypic components, so the latent space admits the direct-sum decomposition
Accordingly, the transport action is block diagonal in the coordinates :
(10b)
Here, is the multiplicity of harmonic : the number of independent two-dimensional feature channels that transform at that rate. The latent dimension is therefore
The harmonic orders determine which phase-dependent transformations the latent space can represent, whereas the multiplicities determine how much feature capacity is allocated to each order. Figure 4 makes the transformation of an individual latent vector explicit. In the canonical coordinates , the invariant coordinates remain fixed, while each of the two-dimensional pairs assigned to harmonic rotates by , so different components of the same latent vector advance at different integer multiples of cardiac phase.
More generally, the orthogonal basis Q may also be learned. One parameterisation uses a product of J Householder reflections,
which guarantees throughout training [49]. The selected architecture in Section 4 instead fixes the canonical basis, so its transport operator has no learnable parameters.
3.2 Learning Equivariant Transport
The WINDER objective combines latent prediction, phase-equivariant transport, and spectral regularisation:
Here, the blue terms are inherited from LeJEPA: trains the latent predictor by requiring the latent magnitude and content to support next-token prediction, while prevents dimensional collapse by controlling the full latent distribution. The orange term, , is specific to WINDER and enforces phase equivariance by constraining how the unit-normalised latent direction changes with cardiac phase.

Figure 3: Fourier decomposition of a phase-equivariant latent trajectory. Local Cartesian panels show the cumulative sum of the first three Fourier components at four cardinal phases. Dashed circles indicate component magnitudes, blue segments show the component-wise construction, orange arrows show the resultant latent vectors, and curved arrows denote quarter-cycle group actions.
Figure 4: Canonical block structure of the transport operator . The block (orange) is fixed under transport; the harmonic blocks (teal) rotate by via , each acting on independent two-dimensional channels.
3.2.1 Latent Prediction
Given a context ending at token t, the causal predictor maps the projected latent prefix to a prediction of the next latent,
The prediction loss is the mean-squared error between the predictor output and the projection head's own output z, averaged over latent dimensions and target positions.
3.2.2 Spectral Regularisation
The prediction and transport objectives do not prevent the encoder from collapsing onto a low-dimensional representation. SIGReg therefore constrains the latent distribution towards a reference distribution .
SIGReg follows LeJEPA's standard random-projection prescription. Rather than comparing distributions directly in the K-dimensional latent space, SIGReg compares their one-dimensional sketches along random unit directions . Matching random one-dimensional projections provides a scalable surrogate for matching the full latent distribution. In practice, the integral is evaluated by numerical quadrature and the projection directions are resampled throughout training.
Once a distribution can be targeted, the remaining question is which distribution to use. To avoid competing with the transport objective, the reference distribution must be invariant under the latent group action. A target is called admissible
| ECG structure | Physiological process | Typical duration [ms] | Characteristic order |
| P wave | Atrial depolarisation | 80–110 | – |
| PR interval | Atrial-to-ventricular conduction | 120–200 | – |
| QRS complex | Ventricular depolarisation | 70–110 | – |
| ST segment | Ventricular plateau phase | 80–120 | – |
| T wave | Ventricular repolarisation | 100–250 | – |
| QT interval | Total ventricular electrical activity | 350–450 | |
| R-R interval | Complete cardiac cycle | 600–1000 |
Table 1: Characteristic timescales of ECG structure. Physiological durations are representative adult values [2]. Characteristic orders follow Equation (20), using ms; sharper morphology may require higher orders.
if
where denotes the pushforward of under , namely the distribution obtained by applying to samples from .
For a centred Gaussian target, , a linear transformation gives
Admissibility therefore requires
In the canonical basis, the most general symmetric admissible covariance is
The term represents covariance between corresponding coordinates of different copies of harmonic . The term represents covariance between orthogonal coordinates—one copy's cosine-like coordinate and another's sine-like coordinate—corresponding to a phase offset of . Here,
and each covariance block is required to be positive definite. When , skew symmetry forces , reducing the harmonic block to .
Different members of this admissible family can encode covariance structures motivated by the underlying mechanism or quantity of interest. For simplicity, however, the LeJEPA choice is adopted, giving , which is invariant under every orthogonal transformation.
SIGReg consequently supplies two complementary anti-collapse pressures. First, it penalises concentration of in a constant or low-dimensional subspace, forcing latents from different sources to occupy distinct regions of the latent space. Second, because the isotropic target assigns variance to every latent coordinate, it penalises concentration in the invariant block and encourages the non-trivial harmonic irreps to remain populated. SIGReg does not determine what those harmonic coordinates encode; the transport objective supplies the phase-dependent structure.
3.2.3 Phase-Equivariant Transport
For two tokens and from the same recording, let and . Because is orthogonal, the squared directional equivariance defect satisfies
The empirical transport loss is therefore
The transport loss enforces equivariance of unit-normalised latent directions, while latent magnitudes are controlled by the prediction and spectral objectives.
This directional objective has a phase-blind failure mode: representations can concentrate in the invariant block, on which acts as the identity. Such representations may satisfy the transport constraint without using the non-trivial harmonic irreps to encode cardiac phase. The transport objective alone therefore does not distinguish useful phase equivariance from trivial phase invariance.
3.3 Bounding the Harmonic Spectrum
The quantisation condition in Equation (8) determines that the admissible harmonic orders are integers. The maximum retained order, , is bounded from below by the clinical timescales needed to be resolved and from above by the resolution of the sensor used to estimate phase.
Let denote the shortest clinically relevant timescale within a cardiac cycle of duration . Since harmonic varies on a timescale propor-

(a)

(b)
Figure 5: Localisation from a gapped harmonic band. (a) Harmonics , with the retained blocks shown in orange. (b) Their normalised sum over a cardiac cycle. The shaded full width at half maximum, , denotes the temporal scale that this harmonic band can resolve, while the gaps leave pronounced side lobes.
tional to , resolving requires
To ground this estimate physiologically, Table 1 relates standard ECG structures to their characteristic Fourier orders. The practical upper bound on is set by the Nyquist limit of the ECG sampling rate. At clinical ECG sampling rates the instrumental ceiling lies well above the orders in Table 1, so the clinical requirement is ordinarily the active constraint. This means that the number of harmonics is specified by the data rather than found by searching over model capacity.
The highest retained harmonic and the feature capacity assigned to each harmonic are separate design choices. For a contiguous spectrum with one copy of each harmonic, every non-zero harmonic requires a two-dimensional real rotation block. The resulting minimum latent dimension is
Additional copies, , provide more independent feature channels at harmonic without increasing the highest supported frequency. Conversely, omitting intermediate harmonics reduces the latent dimension while preserving the scale associated with the highest retained harmonic, but produces less uniform localisation and stronger side lobes. Figure 5 illustrates this trade-off for the band .
In practice, is chosen from the required physiological resolution and acquisition rate, while and are selected on a validation partition held out from the sealed evaluation (Section 4).
4 Method
4.1 Dataset
The PTB-XL dataset [50, 51] was selected because its acquisition and annotation structure match both the mechanism under study and its downstream evaluation. It provides fixed-length, 10-second, 12-lead clinical ECGs at 500 Hz, giving sufficient temporal resolution to construct a cardiac-phase coordinate from R-peak timing. Its patient-aware stratified folds and hierarchical diagnostic labels provide a reproducible route from self-supervised pre-training to diagnostic evaluation. PTB-XL therefore provides an established ECG dataset whose structure directly supports the phase-indexed latent space learning problem.
Version 1.0.3 of the corpus comprises 21,799 recordings from 18,869 patients [52]: clinical resting ECGs, each 10 s long and sampled at 500 Hz across the 12 standard leads. Each recording carries one or more of 71 SCP-ECG statements, assigned by cardiologists and spanning diagnostic, form and rhythm categories.
Classification of the PTB-XL diagnostic subclasses provides the primary evaluation of the learned latent representations. The “23-subclass” metric averages performance across the 17 classes
Standard Communications Protocol for Computer-Assisted Electrocardiography'.
with at least 20 positive fold-9 examples. The five-group macro-average follows PTB-XL's published diagnostic hierarchy, which maps these labels into normal ECG, myocardial infarction, ST/T change, conduction disturbance, and hypertrophy superclasses.
The corpus is used in two stages, separated so that nothing reported on the sealed fold was chosen with reference to it. In the development stage, models are fitted on folds 1–8 and scored on fold 9. That stage fixes the design choices by grid search: the number of encoder layers, the number of predictor layers, and the loss-weight prefactors of Equation (13). It also fixes the isotypic capacity allocation, meaning the split of the 256-dimensional latent budget between the invariant capacity and the harmonic multiplicities of Equation (11). The highest retained harmonic is not tuned in this stage; it is set in advance from the physiological resolution requirement of Section 3.3. Fold 9 is the only partition consulted in making any of these choices, and it is likewise where the eligible subclass list is defined.
In the confirmatory stage, those settings are frozen and the model is pre-trained on the patient-disjoint folds 1–9 (19,601 recordings; 16,965 patients), over which the per-lead normalisation statistics are also fitted. A linear probe on the frozen representation is fitted over the same folds and evaluated on fold 10 (2,198 recordings; 1,904 patients), which remained sealed until unblinding; results reported on it are this paper's headline evaluation. The two partitions agree to within a percentage point on age, sex and every class prevalence (Section A), which is what PTB-XL's stratification should deliver and what was verified rather than assumed.
Recordings are read at the native 500 Hz and decimated locally to 100 Hz by polyphase FIR resampling, giving 1,000 samples per lead. The whole recording is retained as a single training example. Each lead is then z-scored against per-lead corpus statistics fitted once over folds 1–9.
The encoder receives the resampled 100 Hz signal, whereas R-peaks are detected once on the native 500 Hz recordings with a Pan–Tompkins-style detector [53]. Cardiac phase is then estimated by linear interpolation between consecutive peaks, as in Equation (4). Each 80 ms token is assigned the phase at the centre of its patch.
Samples before the first detected peak and at or after the final detected peak have undefined phase, and are excluded from phase-dependent analyses. Section A states the full preprocessing chain and the fitted statistics.
4.2 Model architecture
We implement WINDER as a causal joint-embedding predictive architecture for 10-second, 12-lead ECGs. Each recording is represented by 125 non-overlapping tokens, each corresponding to 80 ms of signal sampled at 100 Hz. The distinguishing component is not the JEPA framework itself, but the fixed phase-indexed transport operator that constrains the projected representation to transform according to cardiac phase (cf. Equation (10b)). Figure 6 shows the complete JEPA architecture, distinguishing the deployed path from components used only during training.
The encoder partitions each input into 125 non-overlapping eight-sample patches. Each patch is flattened to 96 values and passed through the same per-patch MLP, with dimensions and a GELU nonlinearity. The resulting 256-dimensional tokens pass through two residual convolutional blocks with kernel size 3 and dilations 1 and 2 respectively. Left-only padding preserves causality. Across the four convolutions, each output depends on the current token and the preceding 12 tokens, giving a 0.96 s look-back.
Within each context block, the residual branch applies channel-wise LayerNorm, GELU, and causal convolution twice beneath a single identity connection. No normalisation or activation follows the residual addition, and the projector output is likewise left unnormalised. This allows SIGReg to control the scale and moments of the projected distribution, which a terminal LayerNorm would otherwise fix by construction.
A shared projector with dimensions 256 → 512 → 256 and a GELU nonlinearity independently maps each of the 125 contextual encoder tokens to , without mixing information across time. These tokens support the self-supervised training losses. Together, the encoder and projector form the deployed representation path and contain 1,232,384 parameters. For downstream evaluation, tokens with defined cardiac phase are mean-pooled without weighting to form a record-level representation.
The selected transport operator instantiates the block decomposition of Equation (10b) in the 256-dimensional projected space. The invariant capacity is , and the remaining 252 dimensions carry harmonics with multiplicities , each unit of contributing one two-dimensional block, so that . Each coordinate pair in harmonic undergoes a closed-form rotation by .
(a) Representation path
encoder: 969,472 parameters
Input: 12-lead ECG
10 s, 12 × 1000 at 100 Hz
Patchify no parameters
125 patches of 80 ms → 125 × 96
Patch MLP
Linear 96→512, GELU, 512→256
180,992 parameters
Context block A
causal Conv1D, ,
394,240 parameters
Context block B
causal Conv1D, ,
394,240 parameters
Projector
Linear 256→512, GELU, 512→256
262,912 parameters
Projected tokens
Deployed: 1,232,384 parameters
training only, discarded
Predictor
4× causal Transformer blocks
pre-LayerNorm, width 256, 4 heads
FFN 1,024, 3,227,084 parameters
(b) Context block A
tokens
CLN channel LayerNorm, 512
GELU
Causal Conv1D 256→256, ,
left-only pad 2, no bias, 196,608
CLN channel LayerNorm, 512
GELU
Causal Conv1D 256→256, ,
left-only pad 2, no bias, 196,608
output = : , no terminal norm
Block B repeats this anatomy with and left-only pad 4; together the two blocks look back 12 tokens (0.96 s).
Figure 6: WINDER architecture. (a) The encoder maps 80 ms of 12-lead ECG to a 256-dimensional latent space. Fixed patchification, a patch MLP, and two causal context blocks form the 969,472-parameter encoder. The projector produces 256-dimensional latent tokens from the encoder's output. Encoder and projector together form the 1,232,384-parameter deployed path. During self-supervised training the projected tokens also enter the 3,227,084-parameter pre-LayerNorm causal Transformer predictor, which is discarded at deployment. (b) Context block A repeats layer normalisation, GELU, and causal convolution twice under one identity skip, with no normalisation after the residual addition. Left-only padding in the convolutions ensures causality.
The operator is fixed and has zero learnable parameters.
During self-supervised training, the projected tokens also enter a causal Transformer predictor comprising four pre-LayerNorm blocks, four attention heads, width 256, and feed-forward width 1,024. It uses learned relative-position biases. The predictor adds 3,227,084 parameters, increasing the optimised total from the deployed 1,232,384 parameters to 4,459,468. It is discarded after pre-training and contributes neither to deployment nor to the reported diagnostic probes. The masking and prediction-loss mechanics are described in Section 4.3.
Latent-geometry analyses use the pre-projection encoder output to test whether phase structure is learned by the encoder itself. Training losses and diagnostic probes instead use the projected tokens , because these are the representations directly constrained by the objectives and used for downstream evaluation. For diagnostic evaluation, the mean-pooled representation is passed to a linear probe fitted separately for each task. This probe is an evaluation readout, not part of the pretrained model, and its weights are excluded from the reported parameter counts.
4.3 Training
Self-supervised training minimises the three-term objective of Equation (13), with all three terms attached to the projector output z. The live weights are and . The nominal loss weights were selected through a coarse hyperparameter sweep. In the control condition, the transport loss is disabled by setting .
For each record, the prediction loss applies only to the token after a sampled causal cutoff (Section 3.2.1). The cutoff is drawn independently per record, uniformly over admissible token indices, and redrawn every batch. Inputs after the cutoff are replaced by a learned mask token, so the output at depends only on the visible latent prefix and is compared with . The evaluation protocol of the SIGReg loss is given in Section C.1. The transport loss, , is averaged over all valid token pairs within each record, and then across records. Using all valid token pairs avoids the phase-dependent sampling bias observed when only a subset of pairs was selected.
Training uses AdamW with a short linear learning-rate warm-up followed by cosine decay. The optimiser and schedule are fixed across all runs. Their complete specification, including batch size and training duration, is given in Section C.3.
During training, each of six signal augmentations is applied independently with probability 50 %. Gaussian noise and a 25 Hz sinusoid simulate broadband and narrow-band measurement noise, respectively. Low-frequency drift models baseline wander, while slow amplitude modulation represents gradual changes in signal strength. Lead dropout simulates missing channels, and per-lead gain scaling varies the relative amplitudes between leads. Full augmentation details are reported in Section C.2.
Four pre-training runs were conducted: a transport-enabled arm and a control arm, each using two random seeds. The complete run design, checkpoint schedule, and hardware specification are given in Section C.4.
5 Results
Published ECG representation-learning results vary in their pre-training data, parameter scale, input windowing, and downstream readout. A matched ablation therefore isolates the contribution of phase transport. The two arms of the ablation share their data, architecture, random seeds, training schedule, and evaluation protocol. They differ only in the transport objective: WINDER sets , whereas the control disables phase transport by setting . This comparison evaluates the effect of phase transport on downstream performance, use of the declared phase action, and any associated robustness gains or failure modes. Because phase transport acts only during training, both arms have identical inference paths.
The main rows of Table 2 report seed 0 at step 5,000 on sealed fold 10. The training step was selected after the results were known: step 5,000 has the largest seed-averaged superclass gap and the smallest seed-averaged lead-dropout separation. The pre-registered evaluation grid comprised all 12 combinations of two seeds, three training steps, and two arms. Across that grid, the seed-averaged superclass gap ranges from +0.0774 to +0.0910. None of the six matched cross-arm confidence-interval pairs overlaps. The two seeds agree: the largest between-seed spread in any WINDER superclass cell is 0.0054, well inside the confidence intervals. These results provide within-study evidence from one sealed PTB-XL fold. They do not establish generalisation to external datasets or a directly comparable leaderboard ranking.
5.1 Diagnostic accuracy
Each frozen representation is evaluated with the same linear-probe protocol, with uncertainty estimated by resampling patients rather than records over 1,000 bootstrap replicates. Sealed fold 10 holds 2,198 records, of which 2,158 carry a diagnostic superclass. The probe scores 2,140 of these; 18 are excluded because they lack a valid phase assignment after quality control. At the selected cell, WINDER reaches superclass macro-AUROC , compared with for the control. The corresponding 17-class scores are and ; the 23-class scores are and . Phase transport therefore makes diagnostic structure more linearly accessible on the sealed fold. This performance claim is specific to a frozen linear readout. The post-hoc heart-rate stratification reported below weakens, but does not exclude, an explanation of this gap based on heart rate. No published result shares this protocol exactly, so Section D places WINDER within the range reported by self-supervised models on PTB-XL, at a smaller parameter and pre-training footprint, rather than ranking it against them.
5.2 Mechanism validity
For tokens at t and , define the transported and untransported cosine similarities as
(22)
The raw pairwise gain is . Its mean and the reported gain fraction are, respectively,
Thus, the gain fraction normalises the mean gain by the available improvement from the untransported similarity to unit similarity. The pre-registered G1 gate compares this quantity under the true cardiac clock with the result after
| Metric | WINDER () | Control () |
|---|---|---|
| Diagnostic accuracy | ||
| Superclass macro-AUROC, 5 classes ↑ | ||
| Subclass macro-AUROC, 17 classes ↑ | ||
| Subclass macro-AUROC, 23 classes ↑ | ||
| Mechanism validity | ||
| Transport gain fraction ↑ | 0.8786 | -0.0744 |
| G1 shuffled- gate | Pass | Fail |
| Paired true - shuffled gain ↑ | ||
| Robustness to degradation | ||
| Mean signed macro-AUROC, single-lead dropout ↑ | -0.0034 | -0.0107 |
| Worst signed macro-AUROC across single-lead dropouts ↑ | -0.0089 (aVR) | -0.0218 (III) |
| Latent geometry | ||
| Fundamental loop amplitude at | 1.8941 | 0.3817 |
| Fundamental-loop coherence (descriptive), mean over the 7 non-reference bins ↑ | 0.9927 | 0.3159 |
| Anomaly detection (strongest of six families; one fixed detector, maximum severity) | ||
| Ectopic-beat AUROC, severity 2.0 ↑ | 0.8662 | 0.6198 |
| Excess over own zero-severity reference ↑ | +0.2758 | +0.1393 |
| Localisation hit rate ↑ | 0.779 | 0.025 |
| Median latency among alarmed records ↓ | 80 ms | 720 ms |
Table 2: WINDER () vs. control (). Phase transport improves diagnostic accuracy, latent organisation, and lead-dropout robustness at identical inference cost. 95 % CIs are patient-clustered bootstraps. Intervals are 1,000-replicate percentile bounds; remaining values are point estimates. Arrows give the preferred direction; bold marks the better arm where the comparison is non-degenerate. Provenance, protocol, and the caveats attaching to each block are given in the text.
shuffling the phase labels. It requires the paired true-minus-shuffled interval to exclude zero and the shuffled gain fraction to satisfy . WINDER achieves mean gain and gain fraction , and passes G1; the control's gain fraction is and it fails.
The paired true-minus-shuffled gains are for WINDER and for the control. The control interval also excludes zero, so the shuffled-magnitude condition carries the arm discrimination: its shuffled gain fraction is , outside the registered tolerance. The gain fraction itself is a point estimate; the available interval brackets mean gain for WINDER) and cannot be attached to the fraction. This test establishes that the constrained representation uses the declared cardiac clock; it does not by itself explain the diagnostic gain.
5.3 Single-lead robustness.
Each lead is zeroed independently at evaluation while the probe remains fitted on intact data. The resulting AUROC is compared with that arm's own intact score. The mean signed change is -0.0034 for WINDER and -0.0107 for the control, a ratio at step 5,000. The worst signed changes are -0.0089 after removing aVR and -0.0218 after removing lead III, respectively. The seed-averaged mean-degradation ratio widens to by step 30,000. These robustness summaries are descriptive point estimates.
5.4 Latent geometry.
Two complementary metrics quantify phase organisation in latent space. Fundamental-harmonic Amplitude measures how strongly token representations align after removing their cardiac phase, while Orbit-subspace Coherence measures whether phase-bin means remain within a common rotational subspace.
For a token with cardiac phase , the dephased latent is defined as
This counter-rotation brings phase-locked components to the common reference phase . To calculate the Fundamental-harmonic Amplitude, first average the dephased latents per record.

Cardiac phase at bin centre (rad), 24 bins
Figure 7: Latent cardiac-phase organisation with and without transport. Visualisation of the cosine and sine overlaps defined in Equation (27). Tokens are grouped into 24 cardiac-phase bins; each point plots for the mean representation of one bin relative to the reference bin. Each column shows one run: both WINDER seeds and both control seeds. Colour encodes cyclically, so the first and last bins are neighbours in colour as well as in phase. Top row: shared axis limits, so loop size is comparable across panels. Bottom row: each panel normalised by its own RMS radius, so loop shape is comparable. To visualise the same overlap construction at finer phase resolution, tokens from folds 1–9 are grouped into 24 cardiac-phase bins; the sealed-fold coherence estimate uses eight bins.
Then, compute the mean Euclidean norm of the 24 two-dimensional components. The resulting amplitude is 1.8941 for WINDER and 0.3817 for the control, indicating a roughly five-fold stronger phase-locked fundamental component in WINDER.
Orbit-subspace coherence is computed from the original, non-dephased token representations. Tokens are grouped into eight cardiac-phase bins, and the mean representation is calculated for each bin. Let
denote the normalised mean of the reference bin, and let
apply a simultaneous quarter-turn to all two-dimensional blocks. The cosine and sine overlaps of bin b with the reference are
If all blocks undergo one common phase rotation, these overlaps vary as and . Their combined magnitude therefore defines the coherence
A value of one means that the phase-bin mean lies entirely within the rotational plane spanned by u and Ju; lower values indicate components outside this common plane. Mean coherence across the seven non-reference bins is 0.9927 for WINDER and 0.3159 for the control. This metric measures whether the blocks rotate coherently, but not whether the phase bins occur in the correct order around the loop.
The trajectory in Figure 7 complements this metric by showing that the bins also follow their cardiac-phase order around the loop. Tokens are grouped into 24 cardiac-phase bins, and each bin's mean representation is projected onto the two-dimensional subspace in which the rotation acts at the fundamental harmonic ; the four columns are the two WINDER seeds and

Figure 8: UMAP visualisation of latent cardiac-phase organisation. Token-level representations at seed 0 are shown separately for WINDER and the control. UMAP receives no cardiac-phase or diagnostic information, points are coloured post hoc by cardiac phase .
the two control seeds of Section C.4. In both WINDER runs the phase-binned trajectory walks once around a closed circle in bin order; in both control runs it collapses to a small path that neither closes nor preserves the ordering. The figure and the table quantify related but distinct properties on different splits: the RMS loop radius drawn from folds 1–9 separates the arms by roughly a factor of seven, whereas the sealed-fold amplitude separates them by a factor of five. The figure therefore locates the mechanism, while the sealed-fold quantities measure it.
Phase organisation is also visible without the harmonic construction. Figure 8 embeds token-level representations with a general-purpose non-linear projection that receives no phase, arm or diagnosis information, and colours the result by afterwards. Each point is one token, an 80 ms slice of one recording, so colour organisation is a property of the representation rather than of the projection: WINDER's tokens form a phase-ordered annulus and the control's do not. Both figures are encoded from folds 1–9 at the reported evaluation cell and at the training seeds of Section C.4, because the sealed fold did not persist per-record latents; the sealed-fold amplitude and coherence values are those in Table 2. The embedding is a qualitative illustration the geometry claim.
5.5 Anomaly detection
One causal detector was fixed before unblinding and applied unchanged across six synthetic perturbation families. Each maximum-severity result is read against that cell's own zero-severity reference — the same perturbation applied at zero amplitude — because these references differ between arms. For ectopic beats at severity 2.0, WINDER reaches AUROC 0.8662, compared with 0.6198 for the control. The reference-corrected excesses are +0.2758 and +0.1393, and localisation hit rates are 0.779 and 0.025. This is the battery's strongest detection result.
Latency is interpretable only when the detector first clears its own zero-severity reference. WINDER raises an alarm on 92.0% of ectopic-beat records, whereas the control alarms on 14.6%, so the control's 720 ms median is conditioned on a small, unrepresentative subset. The corresponding WINDER median is 80 ms.
That median is exactly one token. The encoder partitions each recording into 125 non-overlapping 80 ms patches (Section 4), and the detector emits one score per token, so an alarm can only be timestamped to a patch boundary and no reported latency can fall below a single patch. The patching we elect therefore sets the floor on this measurement: 80 ms is the finest delay the token grid can express, not a measured bound on how quickly the representation responds to onset. Resolving faster detection would require a shorter patch, and hence more tokens per record. A different admissible detector for seed 0 on the same causal clock reaches 0.916 on this family. Selecting it per cell would have added roughly +0.05 and was excluded by the registered protocol.
The step 5,000 seed-averaged results for the remaining families bound the detection claim. T-wave inversion gives a weak reference-corrected excess of +0.1031 for WINDER against +0.0250 for the control. Amplitude attenuation and lead dropout are effectively undetected, at +0.0138 and +0.0115 for WINDER. Baseline wander reverses after reference correction, with the control responding more strongly (+0.2242 against +0.1240). Together with the ST-shift result, these measurements support no arm-discriminating claim for the other four families.
6 Discussion
WINDER uses a soft physiological prior: the transport loss encourages, but does not force, representations to vary predictably with cardiac phase. The expected phase action is fixed analytically as a set of harmonic rotations. Integer harmonics guarantee that a complete cardiac cycle returns the latent coordinates to their starting point, . Transport gain and latent-geometry measurements then determine whether the learned representation actually follows this prescribed action.
The matched comparison isolates the effect of phase transport; the control differs only by disabling the transport loss. Phase transport improves diagnostic accessibility while strengthening robustness to lead loss. The result is therefore not merely a better readout, but a performance gain accompanied by evidence that the intended cardiac-phase action organises the representation.
This declared geometry also provides a monitorable contract for a compact causal encoder. Phase organisation and transport violations can be quantified directly from the latent representations using metrics defined by the fixed harmonic action. The anomaly results show the promise of this view for continuous monitoring at the point of acquisition, including ambulatory telemetry and bedside rhythm surveillance. These results suggest that phase-aware anomaly scores may support continuous monitoring, but they were evaluated only on synthetic perturbations and do not establish performance in a deployed clinical system.
This work adopts a single corpus and a deliberately simple encoder backbone to give prominence to the method and stress-test the phase-transport mechanism in isolation. The evidence is consequently a controlled within-study comparison under a frozen linear readout, not a common-protocol leaderboard. Having established benefits against the control, future work should evaluate broader corpora and stronger backbones, examine which physiological, morphological, and diagnostic features are encoded by the invariant and harmonic latent subspaces, and extend single-step latent prediction to multi-step forecasts.
More broadly, cardiac phase is one instance of a general construction in which a measured cyclic coordinate defines a fixed harmonic action on latent space, allowing equivariant structure to be introduced without learning the symmetry itself.
7 Conclusions
WINDER introduces a phase-equivariant objective for physiological representation learning. It represents cardiac phase through a fixed, closed-form action on the latent space, whose invariant and phase-rotating harmonic subspaces are specified without learnable transport parameters. The transport objective encourages the learned representations to follow this prescribed action, and the resulting organisation can be measured through transport gain and latent-geometry diagnostics. Notably, because the construction requires only a measured cyclic coordinate, WINDER opens a broader class of phase-equivariant world models for cyclic biosignals, in which physiological structure is injected analytically rather than purchased through parameter scale.
Acknowledgments and Disclosure of Funding
We thank Thorir Mar Ingolfsson for helpful discussions in the preparation of this work. The authors acknowledge the use of resources provided by the Isambard 3 Tier-2 HPC Facility. Isambard 3 is hosted by the University of Bristol and operated by the GW4 Alliance and is funded by UK Research and Innovation; and the Engineering and Physical Sciences Research Council [EP/X039137/1]. This work was supported by Innovate UK, part of UK Research and Innovation (UKRI), under grant number 10201397.
References
[1] Ary L. Goldberger, Zachary D. Goldberger, and Alexei Shvilkin. Goldberger's Clinical Electrocardiography: A Simplified Approach. Elsevier, 10 edition, 2024. ISBN 978-0-323-82475-0.
[2] Arthur C. Guyton and John E. Hall. Textbook of Medical Physiology. Elsevier, 2006.
[3] Lucas Plagwitz, Lucas Bickmann, Michael Fujarski, Alexander Brenner, Warnes Gobalakrishnan, Lars Eckardt, Antonius Büscher, and Julian Varghese. The rlign algorithm for enhanced electrocardiogram analysis through heart rate-corrected ECG alignment for explainable classification and clus-tering. European Heart Journal – Digital Health, 7(5):ztag067, 2026. ISSN 2634-3916. doi: 10.1093/ehjdh/ztag067.
[4] Yann LeCun. A path towards autonomous machine intelligence. OpenReview, 2022. URL https://openreview.net/forum?id=BZ5a1r-kVsf. Version 0.9.2, 2022-06-27.
[5] Mahmoud Assran, Quentin Duval, Ishan Misra, Piotr Bojanowski, Pascal Vincent, Michael Rabbat, Yann LeCun, and Nicolas Ballas. Self-supervised learning from images with a joint-embedding predictive architecture. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, pages 15619–15629, 2023.
[6] Sehun Kim. Learning general representation of 12-lead electrocardiogram with a joint-embedding predictive architecture, 2024. arXiv preprint arXiv:2410.08559.
[7] Saarang Panchavati, Uddhav Panchavati, Hiroki Nariai, Corey Arnold, and William Speier. Laya: A LeJEPA approach to EEG via latent prediction over reconstruction, 2026. arXiv preprint arXiv:2603.16281.
[8] Randall Balestriero and Yann LeCun. LeJEPA: Provable and scalable self-supervised learning without the heuristics, 2025. arXiv preprint arXiv:2511.08544.
[9] Lucas Maes, Quentin Le Lidec, Damien Scieur, Yann LeCun, and Randall Balestriero. LeWorldModel: Stable end-to-end joint-embedding predictive architecture from pixels, 2026. arXiv preprint arXiv:2603.19312.
[10] Jean-Bastien Grill, Florian Strub, Florent Altché, Corentin Tallec, Pierre H. Richemond, Elena Buchatskaya, Carl Doersch, Bernardo Avila Pires, Zhaohan Daniel Guo, Mohammad Gheshlaghi Azar, et al. Bootstrap your own latent: A new approach to self-supervised learning. Advances in Neural Information Processing Systems, 33: 21271–21284, 2020.
[11] T. W. Epps and L. B. Pulley. A test for normality based on the empirical characteristic function. Biometrika, 70(3):723–726, 1983.
[12] Yilun Kuang, Yash Dagade, Tim G. J. Rudner, Randall Balestriero, and Yann LeCun. Rectified LpJEPA: Joint-embedding predictive architectures with sparse and maximum-entropy representations. In International Conference on Machine Learning, 2026.
arXiv:2602.01456; PMLR volume/pages not yet posted.
[13] Léo Nicollier, Max Dunitz, Marc Pic, Pablo Musé, Enric Meinhardt-Llopis, and Gabriele Facciolo. SPHERE-JEPA: Spherical prediction with homogeneous embeddings, 2026. arXiv preprint arXiv:2605.26900.
[14] Haiyu Wu, Randall Balestriero, and Morgan Levine. VISReg: Variance-invariance-sketching regularization for JEPA training, 2026. arXiv preprint arXiv:2606.02572.
[15] Kai Zhao, Dongliang Nie, Yuchen Lin, Zhehan Luo, Yixiao Gu, Deng-Ping Fan, and Dan Zeng. Sub-JEPA: Subspace Gaussian regularization for stable end-to-end world models, 2026. arXiv preprint arXiv:2605.09241.
[16] Lucas Thil, Jesse Read, Rim Kaddah, and Guillaume Doquet. Subspace-decomposed JEPAs: Disentangling progression and content in latent world models, 2026. arXiv preprint arXiv:2605.31111.
[17] Chang Liu, Fei Suo, Yanzhou Jin, Yusuke Iwasawa, Yutaka Matsuo, and Yaonan Zhu. Temporally centered SIGReg improves multi-task LeWorldModel learning: From analysis to method, 2026. arXiv preprint arXiv:2607.26924.
[18] Alexander Chemeris, Ming Jin, and Randall Balestriero. LeNEPA: No-augmentation next-latent prediction for time-series representation learning. In 12th Mining and Learning from Time Series Workshop (MILETS), KDD 2026, 2026. arXiv:2607.00958.
[19] David Klindt, Yann LeCun, and Randall Balestriero. When does LeJEPA learn a world model?, 2026. arXiv preprint arXiv:2605.26379.
[20] Danaé Broustail, Anna Tegon, Thorir Mar Ingolfsson, Yawei Li, and Luca Benini. LuMamba: Latent unified mamba for electrode topology-invariant and efficient EEG modeling. In European Signal Processing Conference (EUSIPCO), 2026. arXiv:2603.19100; EUSIPCO 2026 proceedings not yet posted.
[21] Jonas Petersen, Gian-Alessandro Lombardi, Riccardo Maggioni, Camilla Mazzoleni, Federico Martelli, and Philipp Petersen. HEPA: A self-supervised horizon-conditioned event predictive architecture for time series. In ICML 2026 Workshop on Foundation Models for Structured Data (FMSD), Spotlight, 2026. arXiv:2605.11130.
[22] Jose Geraldo Fernandes, Luiz Facury, Pedro Robles Dutenhefner, and Wagner Meira. Beyond patient invariance: Learning cardiac dynamics via action-conditioned JEPAs, 2026. arXiv preprint arXiv:2604.22618.
[23] Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu, and Aaqib Saeed. CardioState-JEPA: Delay-aware cross-modal learning of a shared cardiac representation, 2026. arXiv preprint arXiv:2608.12944.
[24] Blaise Delaney, Salil Patel, Yuji Xing, Dominic Dootson, Karin Seveghani, and Chrystalina Antoniades. Sonata: A hybrid world model for inertial kinematics under clinical data scarcity, 2026. arXiv preprint arXiv:2604.18058.
[25] Riccardo Grazzi, Julien Siems, Arber Zela, Jörg K. H. Franke, Frank Hutter, and Massimiliano Pontil. Unlocking state-tracking in linear RNNs through negative eigenvalues. In International Conference on Learning Representations, 2025.
[26] Zhikang Chen, Yue Wang, Sen Cui, Yu Zhang, Changshui Zhang, Tianling Ren, and Tingting Zhu. ECG-WM: A physiology-informed ECG world model for clinical intervention simulation, 2026. arXiv preprint arXiv:2605.17580.
[27] M A Al-Masud and Nils Strodthoff. Pretraining strategies and scaling for ECG foundation models: A systematic study, 2026. arXiv preprint arXiv:2605.12241.
[28] Morad Laglil, Bertrand Pracca, Emilie Devijver, and Eric Gaussier. Foundation models and fine-tuning: Toward a new generation of models for time series forecasting, 2026. arXiv preprint arXiv:2607.23146.
[29] Girish Narayanswamy, Maxwell A. Xu, A. Ali Heydari, Samy Abdel-Ghaffar, Marius Guerard, Kara Vaillancourt, Zhihan Zhang, Jake Garrison, Levi Albuquerque, Dimitris Spathis, et al. Towards a general intelligence and interface for wearable health data, 2026. arXiv preprint arXiv:2605.22759.
[30] Linxiao Yang, Xue Jiang, Gezheng Xu, Tian Zhou, Min Yang, Zhaoyang Zhu, Linyuan
Geng, Zhipeng Zeng, Qiming Chen, Xinyue Gu, Rong Jin, and Liang Sun. Baguan-TS: Dual in-context learning model for time series forecasting with covariates. In International Conference on Machine Learning (ICML), 2026.
[31] Xinghong Fu, Yanhong Li, Georgios Papaioannou, and Yoon Kim. Reverso: Efficient time series foundation models for zero-shot forecasting. In 2nd ICML Workshop on Foundation Models for Structured Data, 2026. arXiv preprint arXiv:2602.17634.
[32] Jingru Fei, Kun Yi, Alex Xing Wang, Qing-song Wen, Xiangxiang Zhu, and Wei Fan. Olivia: Harmonizing time series foundation models with power spectral density. In International Conference on Machine Learning, 2026. arXiv preprint arXiv:2605.17340.
[33] Uros Zivanovic, Serafina Di Gioia, Andre Scaffidi, Martín de los Rios, Gabriella Contardo, and Roberto Trotta. Rotary masked autoencoders are versatile learners. In Advances in Neural Information Processing Systems, volume 38, pages 133952–133987, 2025. arXiv preprint arXiv:2505.20535.
[34] Taco Cohen and Max Welling. Group equivariant convolutional networks. In Proceedings of the 33rd International Conference on Machine Learning, volume 48 of Proceedings of Machine Learning Research, pages 2990–2999, 2016.
[35] Michael M. Bronstein, Joan Bruna, Taco Cohen, and Petar Veličković. Geometric deep learning: Grids, groups, graphs, geodesics, and gauges, 2021. arXiv preprint arXiv:2104.13478.
[36] David W. Romero, Erik J. Bekkers, Jakub M. Tomczak, and Mark Hoogendoorn. Wavelet networks: Scale-translation equivariant learning from raw time-series. Transactions on Machine Learning Research, 2023. arXiv:2006.05259.
[37] Daniel E. Worrall and Max Welling. Deep scale-spaces: Equivariance over scale. In Advances in Neural Information Processing Systems, 2019. arXiv:1905.11697.
[38] Lars Graf, Thomas Ortner, Stanisław Woźniak, and Angeliki Pantazi. Flow-State: Sampling-rate-equivariant time-series forecasting, 2025. arXiv preprint arXiv:2508.05287.
[39] Andrea Morandi. Scale-equivariant generative forecasting: Weight-tied dilated convolutions, wavelet scattering inputs, and spectral-consistency training for self-similar time series, 2026. arXiv preprint arXiv:2605.17582.
[40] Irina Higgins, David Amos, David Pfau, Sébastien Racanière, Loïc Matthey, Danilo Rezende, and Alexander Lerchner. Towards a definition of disentangled representations, 2018. arXiv preprint arXiv:1812.02230.
[41] Robin Winter, Marco Bertolini, Tuan Le, Frank Noé, and Djork-Arné Clevert. Unsupervised learning of group invariant and equivariant representations. In Advances in Neural Information Processing Systems, 2022. arXiv:2202.07559.
[42] Giovanni Luca Marchetti, Gustaf Tegnér, Anastasiia Varava, and Danica Kragic. Equivariant representation learning via class-pose decomposition. In Proceedings of the 26th International Conference on Artificial Intelligence and Statistics, volume 206 of Proceedings of Machine Learning Research, pages 4745–4756, 2023.
[43] Jiawen Zhu, Shuhan Liu, Shengxuan Li, Qiming Shi, and Di Weng. POEM: Phase-aware SO(2) feature rotation for time series forecasting under periodicity drift, 2026. arXiv preprint arXiv:2608.03630.
[44] Davide Marincione, Michele Mancusi, Giorgio Strano, Luca Cerovaz, Donato Crisostomi, Roberto Ribuoli, and Emanuele Rodolà. PHALAR: Phasors for learned musical audio representations, 2026. arXiv preprint arXiv:2605.03929.
[45] Bosong Huang, Panzhen Zhao, Zengxiang Li, Patricia Lee, Wei Jin, Alan Wee-Chung Liew, Ming Jin, and Shirui Pan. LVCG: Learning ECG representations in the latent vectorcardiogram space, 2026. arXiv preprint arXiv:2605.31249.
[46] Jintai Chen, Xiangshang Zheng, Hongyun Yu, Danny Z. Chen, and Jian Wu. Electrocardio panorama: Synthesizing new ECG views with self-supervision, 2021. arXiv preprint arXiv:2105.06293.
[47] Yoshihiro Maruyama. Learning with category-equivariant architectures for human activity recognition, 2025. arXiv preprint arXiv:2511.01139.
[48] Elias Stenhede, Edvart Grüner Bjerke, Joanna Sulkowska, Eivind Bjørkan Orstad,
Ole Jakob Elle, Ulysse Côté-Allard, and Arian Ranjbar. Echo-POSED: Geometric self-distillation for echocardiography guidance, 2026. arXiv preprint arXiv:2606.02634.
[49] Zakaria Mhammedi, Andrew Hellicar, Ashfaqur Rahman, and James Bailey. Efficient orthogonal parametrisation of recurrent neural networks using householder reflections. In Proceedings of the 34th International Conference on Machine Learning, volume 70 of Proceedings of Machine Learning Research, pages 2401–2409. PMLR, 2017.
[50] Patrick Wagner, Nils Strodthoff, Ralf-Dieter Bousseljot, Dieter Kreiseler, Fatima I Lunze, Wojciech Samek, and Tobias Schaeffter. Ptb-xl, a large publicly available electrocardiography dataset. Scientific data, 7(1):154, 2020.
[51] Nils Strodthoff, Patrick Wagner, Tobias Schaeffter, and Wojciech Samek. Deep learning for ECG analysis: Benchmarks and insights from PTB-XL. IEEE Journal of Biomedical and Health Informatics, 25(5): 1519–1528, 2021. doi: 10.1109/JBHI.2020.3022989.
[52] Patrick Wagner, Nils Strodthoff, Ralf-Dieter Bousseljot, Wojciech Samek, and Tobias Schaeffter. PTB-XL, a large publicly available electrocardiography dataset. PhysioNet, November 2022. doi: 10.13026/kfzx-aw45. URL https://doi.org/10.13026/kfzx-aw45. Version 1.0.3.
[53] Jiapu Pan and Willis J. Tompkins. A real-time QRS detection algorithm. IEEE Transactions on Biomedical Engineering, BME-32(3):230–236, 1985. doi: 10.1109/TBME.1985.325532.
[54] Siwon Kim. Hierarchical self-supervised representation learning framework for multivariate time series grounded in ECG analysis, 2026. arXiv preprint arXiv:2607.01145.
[55] Kuba Weimann and Tim O. F. Conrad. Self-supervised pre-training with joint-embedding predictive architecture boosts ECG classification performance. Computers in Biology and Medicine, 196:110809, 2025. doi: 10.1016/j.compbiomed.2025.110809.
[56] Yi Yuan, Joseph Van Duyn, Runze Yan, Zhuoyi Huang, Sulaiman Vesal, Sergey Plis, Xiao Hu, Gloria Hyunjung Kwak, Ran Xiao, and Alex Fedorov. Learning ECG representations via poly-window contrastive learning, 2025. arXiv preprint arXiv:2508.15225.
[57] Temesgen Mehari and Nils Strothoff. Self-supervised representation learning from 12-lead ECG data. In Machine Learning for Health, 2021.
A Data protocol
This appendix states the preprocessing chain and phase-clock construction in full, the normalisation convention and the evidence for choosing it, and the composition of the pre-training pool against the sealed fold.
Table 3 gives the preprocessing steps.
All reported runs use a fixed per-lead normalisation: one mean and standard deviation are fitted on the decimated training-fold signals and applied unchanged to every recording. Unlike per-beat or per-recording normalisation, this preserves between-recording amplitude variation within each lead. The values o of the means and standard deviations are given in Table 4.
Section A the demographic and diagnostic composition of the pre-training folds and the test fold. All 19,601 fold-1–9 recordings are used for pre-training, and the normalisation statistics of Table 4 are fitted over the same 19,601. The 222 recordings that fail phase quality control (1.0% of the corpus) are retained in the pool, since a model consuming no phase is unaffected by them and filtering the pool on that criterion would drop recordings for an unrelated reason.
B Per-token phase assignment
Each 80 ms token summarises an eight-sample patch of the decimated signal, so a single scalar phase must stand for the whole patch. Two conventions are used, for different purposes.
Centre convention (training). Each token carries the phase at its patch centre, 3.5 sample intervals after the patch start. Phase tags are computed once per record offline and loaded alongside each waveform batch, so the training loop never re-derives them.
Causal convention (reporting only). Descriptors that must not read beyond a token’s own support — time since the preceding R-peak, distance to the nearest R-peak — instead take the phase at the token’s last sample. This convention never enters training.
Assigning the causal boundary during training would impose a fixed 35 ms offset, which becomes a heart-rate-dependent fraction of the cycle: 0.056 rad standard deviation across records at the fundamental, and 0.39 rad at the highest retained harmonic, n = 7. The error grows with harmonic order because harmonic n advances n times faster in phase, so the tolerance on the token timestamp is set by the highest retained harmonic rather than by the fundamental.
C Training specification
C.1 SIGReg quadrature
For all reported runs, is evaluated on the raw projector tokens z, without rotation into a canonical phase frame (Section B). Each evaluation uses M = 256 random projection directions. At each training step, the projection directions are sampled afresh from the unit sphere.
For each axis, the characteristic-function integral in Equation (2) is approximated using trapezoidal quadrature knots over . The interval exploits the evenness of the integrand and therefore represents the symmetric domain . The Gaussian weighting assigns little mass beyond , while retaining knots over the shorter interval gives finer resolution near the origin, where the integrand varies most. This choice is also supported by the LeJEPA ablation in Table 1a, where and yield comparable linear-probe performance [8]. The absolute scale of SIGReg depends on the quadrature grid.
Two alternative SIGReg frames were tested but not adopted. Demodulating each token to phase zero (the “canonical” frame) produced transport gains from -0.38 to -0.17 and reduced the effective rank to 2.9–11.2. Reducing each record to a canonical template (the “record-canonical” frame) instead yielded zero transport gain because the representations concentrated in the non-rotating invariant block. All reported runs therefore use the raw token frame, with record-level SIGReg disabled.
C.2 Augmentation provenance
Signal augmentation follows precedent from related time-series and ECG models. Reverso includes augmentation in its zero-shot forecasting recipe, although its ablation assigns a larger effect to synthetic pre-training data [31]. In the ECG setting, ER-JEPA independently applies baseline wander, Gaussian noise, and power-line noise during pre-training [54]. These works motivate signal augmentation generally, but do not validate the specific six-transform stack used here.
The stack itself was selected in a preliminary architecture-scouting experiment rather than from
| # | Step | Operation and parameters |
|---|---|---|
| 1 | Read | The 16-bit waveform release at 500 Hz is converted to physical millivolts in single-precision floating point as (raw – baseline)/gain, scaled by the declared unit factor of the recording header. Each signal’s stored checksum is verified. |
| 2 | Verify extent | Each recording is required to contain 5,000 samples across 12 leads, every sample finite, before any filtering. A header that does not declare Hz is rejected. |
| 3 | Verify lead order | I, II, III, aVR, aVL, aVF, V1–V6, checked against each recording’s own header. A mismatch is rejected rather than corrected by reordering. |
| 4 | Decimate | Hz by polyphase resampling with interpolation factor 1 and decimation factor 5: a single linear-phase Kaiser-windowed FIR filter, with group delay compensated internally, so output sample corresponds to input time with no timing shift. The signal is extended at each endpoint by its boundary value rather than by zeros, so a non-zero baseline introduces no step discontinuity at or s. |
| 5 | Window | The whole recording: 1,000 samples across 12 leads. No cropping, no stride, no overlap — exactly one training example per recording. |
| 6 | Normalise | Per-lead -score against corpus statistics fitted on the decimated signal over the training folds only (Table 4). |
| 7 | Arrange layout | Lead-major, 12 leads by 1,000 samples, in single-precision floating point. |
Table 3: ECG preprocessing pipeline.
| Lead | [mV] | [mV] | Lead | [mV] | [mV] |
|---|---|---|---|---|---|
| I | -0.002 | 0.171 | V1 | 0.000 | 0.234 |
| II | -0.001 | 0.167 | V2 | -0.001 | 0.338 |
| III | 0.000 | 0.172 | V3 | -0.001 | 0.335 |
| aVR | 0.002 | 0.143 | V4 | -0.002 | 0.311 |
| aVL | -0.001 | 0.147 | V5 | -0.001 | 0.291 |
| aVF | -0.001 | 0.147 | V6 | -0.001 | 0.243 |
Table 4: Per-lead normalisation statistics. Fitted corpus normalisation statistics. and are the per-lead mean and standard deviation.
the four pre-training runs reported in Section 4.3. This experiment used one random seed, 5,000 training steps, a 6,000-record training subset, and evaluation on fold 9. The full augmentation stack achieved a macro-AUROC of 0.8589, compared with 0.8513 for the control arm. This provides preliminary support for carrying the stack forward, but does not estimate uncertainty or isolate the contribution of individual augmentations. See Table 6 for the complete specification.
C.3 Optimiser and schedule
All optimiser and schedule settings were fixed across the four pre-training runs and were not swept; their values are given in Table 7. Training uses AdamW with a linear warm-up followed by cosine learning-rate decay.
| Folds 1–9 | Fold 10 | |
|---|---|---|
| Recordings | 19,601 | 2,198 |
| Patients | 16,965 | 1,904 |
| Age, median (years) | 61 | 63 |
| Age, interquartile range | 50–72 | 50–74 |
| Age sentinel (age = 300) | 259 | 34 |
| Male, % | 52.2 | 51.5 |
| Normal ECG (NORM), % | 43.6 | 43.8 |
| Myocardial infarction (MI), % | 25.1 | 25.0 |
| ST/T change (STTC), % | 24.0 | 23.7 |
| Conduction disturbance (CD), % | 22.5 | 22.6 |
| Hypertrophy (HYP), % | 12.2 | 11.9 |
| UNLABELED recordings | 371 | 40 |
| Beats per recording, median | 12 | 12 |
| Phase yield, median | 0.908 | 0.909 |
| Recordings failing phase QC | 202 | 20 |
Table 5: Pre-training and sealed-fold cohort composition. Diagnostic prevalences are multi-label and may sum to more than 100%. UNLABELED denotes recordings without an eligible diagnostic statement. The age = 300 sentinel denotes de-identified patients over 89. Phase yield is the fraction of samples assigned a phase. Phase-QC failures remain in the self-supervised pool but are excluded from phase-dependent analyses.
C.4 Four training runs
The experiment follows a two-arm, two-seed design. The transport-enabled arm uses ,
| Augmentation | Operation | Parameters |
|---|---|---|
| Gaussian noise | Add independent Gaussian noise to the waveform. | Zero mean; standard deviation equal to 5% of the record RMS. |
| Narrow-band tone | Add a sinusoidal interference component. | Frequency: 25 Hz. Amplitude: uniform on 5%–20% of record RMS. Phase offset : uniform on . One shared tone, identical across leads. |
| Low-frequency drift | Add a slowly varying baseline component. | Sum of 1–3 sinusoids, count drawn uniformly from ; each component's frequency uniform on 0.05–0.4 Hz and amplitude uniform on 5%–20% of record RMS, with an independent phase offset uniform on . Shared across all leads. |
| Amplitude modulation | Multiply the waveform by a slowly varying amplitude envelope. | Envelope . Depth : uniform on 2%–10%. Frequency : uniform on 0.05–0.3 Hz. Phase offset : uniform on . One record-global envelope, identical across leads. |
| Lead dropout | Set complete ECG leads to zero. | Number of dropped leads : uniform on . The leads are a uniformly random subset of the 12, drawn without replacement, independently per record. |
| Per-lead gain | Scale each ECG lead independently. | Gain : drawn independently and uniformly on for each of the 12 leads, independently per record. |
Table 6: Training-time augmentation settings. Each transform is applied independently to each record with probability 0.5, gated independently per augmentation type. All additive amplitudes are a fraction of that record's own clean-input RMS, computed once before any augmentation is applied, so a stacked dose always refers to the same physical scale.
| Hyperparameter | Value |
|---|---|
| Optimiser | AdamW |
| Batch size | 64 |
| Training steps | 30,000 |
| Peak learning rate | |
| Minimum learning rate | |
| Warm-up steps | 5 |
| AdamW | (0.9, 0.95) |
| AdamW | |
| Weight decay | |
| Maximum gradient norm | 1.0 |
Table 7: Optimiser and schedule hyperparameters. Used for all reported pre-training runs.
while the control retains the same cyclic operator but assigns the transport loss zero weight. All remaining model, data, and optimisation settings are identical across the four runs. Within each seed, randomness is separated into independent streams for parameter initialisation, mask sampling, SIGReg projections, augmentation, and data order. The active stream states are stored in each checkpoint. Checkpoints are saved every 2,500 steps and at the end of training.
| Arm | Seed | Elapsed [min] | |
|---|---|---|---|
| Transport | 0 | 1.0 | 249.6 |
| Transport | 1 | 1.0 | 254.9 |
| Control | 0 | 0.0 | 240.0 |
| Control | 1 | 0.0 | 225.3 |
Table 8: Four pre-training runs. Elapsed time is the wall-clock training time recorded for each run.
Training was performed on a single NVIDIA A100 40 GB GPU in two matched concurrent pairs, with approximately 11.7 GB peak memory per pair.
D Positioning within PTB-XL self-supervised learning
This appendix situates WINDER (1.2M parameters) within the published self-supervised ECG representation-learning literature on PTB-XL. The comparison is restricted to methods that report PTB-XL diagnostic performance and provide sufficient information about their pre-training data, model scale, and downstream evaluation protocol. The resulting set is curated, not exhaustive: its purpose is to identify the nearest methodological and empirical reference points for WINDER, not to construct a leaderboard. Despite its ubiquity in the literature, there is no shared protocol for PTB-XL evaluation.
LeNEPA (3.6M ) provides the nearest methodological comparison. Both methods combine causal latent prediction with SIGReg, however there are two key differences in how embedded windows are related: LeNEPA applies SIGReg to the sequence of token embeddings from each ECG, preventing collapse without giving their arrangement a cardiac-phase meaning; WINDER includes the equivariant transport loss that requires latents to follow measured cardiac-phase.
Beyond LeNEPA, the principal signal-only JEPA references are S4-JEPA (3.0M) and the models of Weimann and Conrad [55] and Kim [6]. Weimann JEPA is evaluated at several scales; here, we consider only the smallest, ViT-XS (3.6M), as the closest scale comparison to WINDER. It uses masked prediction, is pretrained on configurations ranging from PTB-XL alone to ten ECG corpora, and evaluates frozen representations through learned cross-attention pooling over 2.5 s crops. ECG-JEPA (87.2M) instead uses a substantially larger Transformer with cross-pattern attention, pre-trained on 174,140 external ECGs and evaluated through mean-pooled frozen representations. Neither method assigns cardiac phase an explicit action in the latent space.
Readout capacity is itself a material protocol difference. Weimann’s learned cross-attention pooling can adaptively combine crop-level features, whereas WINDER uses parameter-free mean pooling followed by a linear classifier. Table 9 therefore does not support a head-to-head accuracy claim. The narrower result is that phase-transport training yields diagnostic information that remains accessible to a deliberately low-capacity readout, without a learned sequence aggregator. This is directly relevant to deployment because the downstream readout adds only a linear classifier.
Contrastive predictive objectives provide a complementary set of self-supervised references. S4-CPC (3M) of Al-Masud and Strodthoff [27] is compact but is pre-trained on 11.2 million external ECG samples, and its reported PTB-XL split is insufficiently specified for direct comparison. ECG-CPC (5.8M) is similarly compact, but reports the all-71 task and does not clearly restrict PTB-XL pre-training to the downstream training folds. Poly-Window [56] (3.8M ) most closely matches WINDER's 100 Hz, full-record frozen-probe evaluation, although self-supervised pre-training folds are not reported.
CardioState-JEPA [23] (94.3M ) provides a separate cross-modal reference, learning a shared representation from ECG, PPG, and PCG with cardiac phase included as an auxiliary prediction target. This differs from WINDER, which uses ECG alone and imposes phase as a fixed group action on the latent space rather than as a quantity to predict. Their ablations independently suggest that cardiac-phase supervision is useful, although phase is treated as a prediction target rather than an equivariant constraint. CardioState-JEPA is therefore relevant to cardiac-state representation, but its multimodal pre-training prevents a direct signal-only comparison.
Although none of the published results is directly comparable with WINDER under a fully matched protocol, its diagnostic performance lies within the same broad range as the selected self-supervised models. WINDER reaches this range with a 1.2M-parameter model, pre-training restricted to 19,601 PTB-XL records, and parameter-free mean pooling followed by a linear classifier. Several reference methods use more expressive learned readouts, including Weimann's cross-attention pooling. Table 9 therefore supports a narrower, deployment-relevant claim: phase-transport training produces representations from which diagnostic information is linearly accessible without a learned sequence aggregator.
Italicised parameter counts are estimates rather than values explicitly reported by the source. This count is estimated from the released PTB-XL ViT-XS configuration.
Estimated from the canonical 1D ResNet18-512/128 architecture.
Estimated from the released configuration at repository commit ab242c3.
| Method | Parameters [M] | Pre-training examples | PTB-XL in pre-training? | PTB-XL evaluation protocol | AUROC |
|---|---|---|---|---|---|
| Latent-prediction objectives | |||||
| WINDER | 1.2 | 17k | ✓ | 100 Hz; full 10 s record; frozen representation with a plain linear probe; folds 1–8 train and fold 10 test | 0.8702 |
| S4-JEPA [27] | 3.0 | ✕ | 240 Hz; frozen mean-pooled linear evaluation; concrete PTB-XL fold assignment not stated | 0.880 | |
| LeNEPA [18] | 3.6 | N.A. | ✓ | 5,000-sample records; fixed-horizon pre-training; frozen intermediate-layer probe; label mapping insufficiently specified | |
| JEPA [55] | ViT-XS | 1.0M | ✓ | 500 Hz; 2.5 s crops with record-level probability averaging; frozen encoder with learned cross-attention pooling | 0.915 |
| JEPA ViT-XS | 3.6 | 0.80M | ✕ | Same protocol as the all-corpora JEPA row | 0.915 |
| JEPA ViT-XS | 3.6 | 17k | ✓ | Same protocol as the all-corpora JEPA row | 0.912 |
| ECG-JEPA [6] | 87.2 | 0.17M | ✕ | Eight leads at 250 Hz; full 10 s record; frozen mean-pooled representation with linear classifier; official folds | 0.912 |
| CardioState-JEPA [23] | 94.3 | ✕ | Cross-modal ECG-PPG-PCG pre-training; frozen linear probe; official-style PTB-XL split | 0.891 | |
| Contrastive objectives | |||||
| S4-CPC [27] | 3.0 | ✕ | Same protocol and split limitation as S4-JEPA | 0.860 | |
| Poly-Window [56] | 3.8 | 22k | ✓ | 100 Hz; full 10 s record; frozen encoder with linear classifier; official downstream folds | 0.891 |
| ECG-CPC [57] | 5.8 | 55k | ✓ | 100 Hz; frozen linear evaluation with 2.5 s crop aggregation; all 71 statements | N.A. |
The S4 studies report pre-training samples rather than complete ECG records. CardioState-JEPA combines ECG records, PPG segments, PCG recordings, and paired multimodal corpora; the paired-corpus counts are not reported. LeNEPA’s reported AUROC uses all 71 PTB-XL labels rather than the five diagnostic superclasses.
Table 9: Published self-supervised comparisons on PTB-XL. Results are reproduced in each source’s original evaluation setting and are not a common leaderboard. AUROC values refer to the five diagnostic superclasses. Green, orange, and red shading in the parameter and pre-training-example columns denotes , , and WINDER values, respectively. Despite differences in evaluation protocols, WINDER achieves AUROC values in the same broad range as the selected models while using fewer parameters and less pre-training data.