Toward Vision Language Model-based Assessment of Clinical Quality and Usability of LGE-MR Images for Cardiac Ablation Planning

Bipasha Kundu, Abhishek Chaturvedi, Axel W. E. Wismueller, Richard Simon, Cristian A. Linte

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Bipasha Kundu 1^{1}, Abhishek Chaturvedi 3^{3}, Axel W. E. Wismueller 3^{3}, Richard Simon 2^{2}, and Cristian A. Linte 1,2^{1,2}

1^{1} Carlson Centre of Imaging Science, RIT, Rochester, NY, USA

2^{2} Biomedical Engineering, RIT, Rochester, NY, USA

3^{3} Department of Imaging Sciences, University of Rochester Medical Center, NY, USA {bk7944, calbme}@rit.edu

Abstract. Late gadolinium-enhanced (LGE) cardiac MRI is widely used for left atrial (LA) fibrosis assessment and ablation planning in atrial fibrillation patients as knowledge of fibrotic tissue regions identified from LGE-MRI is critical for catheter ablation. Often times, poor quality images used during ablation planning can cause mislocalization of ablation targets, therefore directly impacting procedure safety and outcome. The decision of whether a scan meets the minimum quality threshold for ablation planning is currently made informally by the reviewing radiologist and is not captured by any automated system, yet it is arguably the most safety-critical output of the image quality assessment (IQA) process. However, variations in image quality caused by noise, motion artifacts, and poor boundary definition significantly compromise the reliability of downstream segmentation and clinical decision-making tasks. Manual quality assessment by expert radiologists is subjective and difficult to scale, while existing automated methods produce scalar scores without interpretable clinical reasoning. In this work, we propose a two-stage vision language model (VLM) framework for clinically grounded image quality assessment of left atrial LGE-MRI. In the first stage, a fine-tuned VLM generates structured radiology-style quality reports predicting five radiologist-defined criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and reports to a structured quality scores and binary clinical usability decision for ablation planning. We curate a dataset of 60 annotated image slice-text pairs from 20 patients and benchmark four state-of-the-art VLM architectures. InternVL2 achieves the highest criterion-level accuracy (Avg ACC=0.65, PLCC=0.79), while DeepSeek achieves perfect clinical usability agreement (Acc=1.00, kappa=1.00). These results demonstrate the feasibility of using VLM based automated quality control for clinical workflows that entail the use of MR images.

Keywords: Artificial intelligence · large language model · vision-language model · ChatGPT · image quality assessment · ablation planning

B. Kundu et al.

1 Introduction

The emergence of Large Language Models (LLMs) has marked a paradigm shift in the area of natural language processing. Models such as GPT, LLama, and Gemini [1,20,22] have demonstrated excellent capabilities in generating human-like text across a wide range of tasks such as natural language reasoning, question answering, and structured text generation [19]. However, despite these advances, LLMs are inherently limited to the textual data and cannot directly process the visual data.

To address this gap, recent research has focussed on extending LLMs into the visual domain through Vision Language Models (VLMs) by jointly encoding the visual and textual information with their strong vision encoder and language model backbones. Most popular VLMs such as LLaVA [15], DeepSeek [16], Qwen [6], and InternVL [25] can generate structured textual responses, commonly known as human-interpretative responses of visual content, which bridges the gap between perception and semantic understanding.

The medical domain is well positioned to benefit from such VLM based approaches. Recent studies have demonstrated that VLMs can generate clinically relevant reports, answers visual questions, identify different organs, and assist in disease diagnosis based on X-ray, CT and ultrasound imaging exams [4,7,23,24,26][4,7,23,24,26]. These studies suggest that VLMs has the potential to serve as a complement to expert radiologists, particularly where annotation capacity is limited and expensive.

While LLM-VLMs have been explored across various medical imaging tasks, their application towards image quality assessment (IQA) is very limited. IQA plays a very important role in downstream image processing tasks including segmentation, registration, and clinical diagnosis [8–11] by aiming to approximate human perception of image quality. A clear and specific example is the crucial role of cardiac MRI as part of cardiac ablation therapy workflows, where LGE-MRI is widely used to guide subsequent catheter ablation procedure planning by enabling the segmentation, localization and visualization of the scar tissue regions relative to the left atrial geometry and the pulmonary vein anatomy. As such, the accuracy of the subsequent ablation therapy planning workflow hinges upon the quality of these images, and poor image quality can lead to unreliable delineation of anatomical structures and subsequently potentially sub-optimal treatment planning [2].

In clinical practice, the quality assessment of MRI is typically performed by expert radiologists prior to performing quantitative analysis, but this process is subjective, time consuming and difficult to scale. There are also several quantitative methods for IQA in MRI imaging [3], but most of them rely on reference images that may not exist. Furthermore, these methods use objective metrics such as peak-signal-to-noise-ratio (PSNR), contrast-to-noise-ratio (CNR) or root-mean-square-error (RMSE) which are not consistent with the subjective evaluation [17]. Factors such as anatomical visibility, signal noise, contrast, and overall interpretability influence the clinical decision. This process is subjective and time-consuming, and currently there exists no scalable, automated system that reproduces expert-style quality assessment for cardiac MRI that can assess multiple quality dimensions together and produce an interpretable, actionable clinical output.

VLMs offer a promising solution to these limitations. Unlike scalar regression or objective metric-based approaches, VLMs can generate structured, human-interpretable quality reports describing multiple clinically relevant criteria simultaneously, including noise severity, motion artifact extent, boundary clarity, and pulmonary vein visibility. Critically, ablation planning requires not just criterion-level scores, but a definitive binary usability judgment with respect to whether a scan meets the minimum quality threshold to support reliable LA segmentation and ablation target identification. This decision cannot be derived from any single criterion in isolation — an image featuring acceptable noise, but poor boundary definition remains unsuitable, while an image that features elevated noise, but intact boundary and PV accuracy may still support planning. A secondary LLM reasoning layer can map predicted multi-criteria reports to the desired binary decision, explicitly linking image quality to downstream ablation planning in a clinically conservative and interpretable way. The closest prior work by Orkild et al. [17] proposed automated IQA for LGE-MRI in atrial fibrillation patients using traditional scalar metrics. However, it neither generates interpretable multi-criteria quality reports nor produces an automated binary usability decision for ablation planning. Despite their envisioned potential, no prior work has demonstrated that VLM-predicted quality attributes can be reliably translated into clinically grounded usability decisions [4], and hence these decisions remain informal and un-automated in current clinical practice.

In this work, we propose a two-stage VLM-based framework for clinically grounded image quality assessment of left atrial LGE-MRI images. In the first stage, a fine-tuned VLM generates a structured radiology-style quality report that predicts five criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and report to a structured score and binary clinical usability decision for ablation planning. Our contributions are as follows: (1) We curate a set of 60 MRI image quality assessment datasets annotated across five criteria by expert radiologists (2) We introduce a two-stage VLM-LLM framework that generates structured radiology-style quality reports and maps them to binary clinical usability decisions; (3) We benchmark four state-of-the-art (SOTA) VLMs under parameter-efficient fine-tuning (PEFT), evaluate using ordinal scores and clinical usability metrics, and demonstrating proof-of-concept feasibility for automated cardiac MRI quality control.