Manuscript Offprint

arXiv:2609.40091

GateSPINE: Gated Cross-View Fusion for Lumbar Spine MRI Report Generation

Hoang Nguyen Van, Cuong Vuong Tuan, Trang Mai Xuan, Bien Tran Van, Nam Tran Van, Thien Van Luong

Hoang Nguyen Van 1^{1}, Cuong Vuong Tuan 1^{1}, Trang Mai Xuan 1∗^{1*}, Bien Tran Van 2,3^{2,3}, Nam Tran Van 3^{3}, and Thien Van Luong 4^{4}

1^{1} Applied AI Lab, Phenikaa University, Hanoi, Vietnam

2^{2} Medical Imaging & Radiological Technology Department, Faculty of Medical Technology, Phenikaa School of Medicine & Pharmacy, Phenikaa University, Vietnam

3^{3} Radiology & Functional Exploration Center, Phenikaa University Hospital, Vietnam

4^{4} Business AI Lab, College of Technology, National Economics University, Vietnam 23010101@st.phenikaa-uni.edu.vn, {cuong.vuongtuan, trang.maixuan, bien.tranvan}@phenikaa-uni.edu.vn, bv.namtv@phenikaamec.vn, thienlv@neu.edu.vn

Abstract. Automated report generation can ease the burden radiologists face when interpreting multi-sequence MRI studies. Unlike CT, MRI examinations comprise multiple sequences and imaging planes, each contributing complementary diagnostic information. Existing methods encode a study as a single volume and combine multiple acquisitions by fixed rules. Findings visible in only one plane are thus diluted and often missed, lowering recall on clinical efficacy metrics, where a missed abnormality is most costly. We propose GateSPINE, a vision-language framework that fuses sagittal T1 and T2 volumes with a training-free operator, encodes the fused sagittal and axial volumes with two parallel 3D encoders, and decodes their combined representation into a report. Its core mechanism is a gated cross-view fusion module that predicts, per feature channel and token, how much of each view to admit, so the more informative view dominates at each spatial location. We evaluate GateSPINE on three lumbar MRI datasets, comprising two public benchmarks and a private cohort collected from Phenikaa University Hospital, using both natural language generation (NLG) and clinical efficacy (CE) metrics. GateSPINE achieves the highest CE F1 through improved recall on all three datasets; on SPIDER, which lacks an axial sequence, this reflects the sagittal fusion component rather than the gated cross-view mechanism, which is validated on the two cohorts with both imaging planes. GateSPINE also remains competitive on standard NLG metrics.

Keywords: Lumbar spine MRI · Medical report generation · 3D vision encoders · Gated cross-view fusion · Clinical efficacy.

  • Corresponding author.

H. V. Nguyen et al.

1 Introduction

Magnetic resonance imaging (MRI) is widely used to evaluate degenerative lumbar spine diseases because it provides detailed visualization of soft tissues and neural structures [1, 14]. In clinical practice, radiologists must examine multiple MRI sequences (e.g., T1W and T2W) acquired from different imaging planes (e.g., sagittal and axial), integrate the complementary findings across these images, and produce a comprehensive diagnostic report. This process is time-consuming because it requires careful interpretation of a large volume of imaging data, so automatic radiology report generation has attracted increasing attention [4, 11, 12].

Automatic report generation from CT typically couples a 3D vision encoder with a language decoder [11]. Most recently, Reg2RG [7] grounds the report on anatomical regions and combines region-level with global features, substantially improving diagnostic accuracy. These methods assume that a study is a single volume, whereas an MRI examination comprises several sequences and imaging planes, each showing some findings more clearly than the others. For lumbar spine MRI specifically, SPINE [12] stacks sagittal T1- and T2-weighted images together with segmentation labels, showing that integrating complementary contrasts improves report quality. Yet it models the sagittal view alone. This omission is consequential because lateral recess stenosis, facet hypertrophy, and the lateralization of disc herniation are assessed on axial images, findings that a sagittal-only model can therefore characterize only in part. CrossSpine [16] attends across sequences to predict degeneration grades, but represents each by a single 2D slice. The two views are not interchangeable. Sagittal images trace continuity along the spinal axis and capture disc height, alignment, and marrow signal across all levels at once, whereas axial images expose a per-level geometry that sagittal slices cannot reconstruct. Which view carries the decisive evidence therefore changes from finding to finding, which a fixed combination rule cannot accommodate. To our knowledge, learning to combine sagittal and axial views for lumbar report generation remains unexplored.

To address this gap, we propose GateSPINE, a unified vision-language framework for lumbar MRI report generation. GateSPINE first merges sagittal T1 and T2 with a training-free dynamic fusion operator, then encodes the fused sagittal and the axial volumes with two parallel 3D vision encoders. A lightweight gated cross-view fusion module learns, per feature channel, how much of each view to retain, and the resulting representation is decoded into a report by a vision-language model. In summary, our contributions are as follows:

– We propose GateSPINE, a unified vision-language framework that integrates multi-sequence fusion, parallel 3D vision encoders, and adaptive cross-view fusion, improving both clinical-efficacy and language-generation performance.

– We design a lightweight gated cross-view fusion module that adaptively combines sagittal and axial representations. The module learns to emphasize the view that provides more informative evidence for each feature channel and spatial position, leading to more effective use of complementary information across MRI sequences and imaging planes.

– On the private PhenikaaMec cohort and two public datasets (SPIDER, Lumbar), GateSPINE improves clinical-efficacy micro-F1 over the strongest baseline by 3.6, 3.6, and 26.9 points, driven by recall gains of up to 38.0 points; on SPIDER, which lacks an axial sequence, this reflects the sagittal fusion component rather than the gated cross-view mechanism. GateSPINE also achieves the highest BERTScore on all three datasets (+0.3, +1.3, and +0.4 points).

References (42)