Manuscript Offprint

arXiv:2608.21207

Curriculum-Aware Interpolate-then-Refine: Learned Physiological Time-Series Imputation under Realistic Missingness

Yu-Chao Huang, Haochen Zhang, Nicholas Konz, Tianlong Chen

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Yu-Chao Huang, Haochen Zhang, Nicholas Konz, and Tianlong Chen

1^{1} UNITES Lab, University of North Carolina at Chapel Hill

Imputing physiological time series (arterial blood pressure, blood glucose, etc.) is essential for addressing the missingness that pervades clinical data. Yet modern imputation methods perform poorly in this domain: a recent benchmark found that simple linear interpolation outperformed every learned imputer on real-world clinical signals with realistic gaps. We show that this reflects two properties of physiological missingness that generic imputers ignore: gaps may occur when the signal is clinically extreme rather than typical, and gap lengths can easily span orders of magnitude. To this end, we introduce Curriculum-Aware Interpolate-then-Refine (CAIR), a two-stage framework for physiological time-series imputation. Our key motivation is to learn a coarse base curve and then repeatedly correct it toward physiological realism, rather than predict a gap in a single pass. Consequently, CAIR couples a bidirectional-GRU interpolator with a Transformer refiner that corrects its own estimate over three successive passes, trained jointly under a broad, signal-agnostic random-gap curriculum. We evaluate imputers stratified by gap length and missingness mechanism (MCAR, MAR, NMAR) rather than by a single average, and CAIR is the most accurate under every mechanism on continuous glucose monitoring (AI-READI) and arterial pressure in intensive care (MIMIC-III). Its margin over the strongest baseline grows with difficulty, from 9% under MCAR to 19% under value-dependent dropout, where generic learned imputers are weakest. We further show low reconstruction error alone does not recover the burden metrics clinicians act on: interpolants matching CAIR's error fail to preserve those metrics, imputers that recover them are far less accurate, and CAIR alone ranks among the best on both axes.

1 Introduction

Physiological time series, such as continuous glucose monitoring (CGM), heart rate, respiration and intensive-care vital signs, are the raw material of modern data-driven medicine, and they are rarely complete (Pratap et al., 2020; Braem et al., 2024; De Andrade et al., 2026). Sensors detach, wearables run out of battery, patients move, and clinical devices are disconnected during procedures (Braem et al., 2024; Bent et al., 2020). Every downstream step, from computing a glycemic burden metric (Kok et al., 2026) to training a risk model (Hurst et al., 2024), first has to decide what the missing values were. Imputation is therefore not a preprocessing detail but a modeling choice that propagates into every clinical conclusion drawn from the data (Cichosz et al., 2025; Poette et al., 2026).

The obvious remedy is a learned imputer, and a rich family now exists (Cao et al., 2018; Du et al., 2022; Tashiro et al., 2021; Wu et al., 2022). Yet a recent real-world benchmark reports a negative result:

Corresponding authors: {morris, haochenz, nick124, tianlong}@cs.unc.edu

Preprint. Under review.

Curriculum-Aware Interpolate-then-Refine: Learned Physiological Time-Series Imputation under Realistic Missingness

(a) Missingness in physiological data

Figure

(b) Classical interpolation

(c) Generic learned imputers

(d) CAIR (ours)

Figure 1: Method Overview. Notation: x∈RTx \in \mathbb{R}^T is the complete signal and m∈{0,1}Tm \in \{0,1\}^T its observation mask ( mt=1m_t = 1 where xtx_t is recorded), so the elementwise product x⊙mx \odot m is the observed (gapped) trace; cc collects the co-recorded context channels (steps, sleep, stress, a second vital); ff is an imputer and x^=f(x⊙m,m)\widehat{x} = f(x \odot m, m) its reconstruction; and y0y^0 is the Stage-1 base curve. Shaded bands mark masked spans throughout. Every trace is recorded AI-READI CGM: (a) is one participant's 24 h day, (b)–(d) zoom into one postprandial excursion from it, and the top row of (b) zooms further so that a 15 min gap is visible. (a) The five masking regimes this paper evaluates, all on one signal: MCAR scatters isolated points; MAR deletes contiguous blocks triggered by co-recorded activity; NMAR deletes blocks triggered by the target's own clinically extreme values (here every run above 150 mg/dL); the gap-length protocol sweeps a single block from 15 min to hours; and the physiological protocol masks event-aligned blocks. Dotted grey is the signal each mask removes. (b) Deterministic interpolants are the deployed default and are accurate on short gaps, but whatever they place inside a gap is a function of the two endpoints alone, so a long gap is filled by a chord that cannot express the excursion it spans. (c) Generic learned imputers are trained under MCAR, the one regime that does not occur, and damp the excursion they must recover. (d) CAIR learns that base curve instead of computing it: a jointly trained BiGRU interpolator whose base curve y0y^0 enters a Transformer refiner both as conditioning and as a residual base, unrolled for three passes and conditioned on whatever co-recorded context the deployment setting provides.

on clinical signals with realistic gaps, linear interpolation outperforms every method tested, including deep learning models (Toye et al., 2025). We argue this is not evidence that learning cannot help, but a symptom of two properties of physiological missingness that generic imputers and the standard evaluation protocol both ignore:

(C1) Missingness is mechanism-driven, not random. We adopt the taxonomy of Rubin (1976), under which missingness is missing completely at random (MCAR) when the probability that a sample is lost is independent of the data, missing at random (MAR) when that probability depends only on observed quantities such as a co-recorded covariate, and missing not at random (NMAR) when it depends on the missing value itself. Physiological sensors fail more often during activity and during the clinical extremes that matter most, so their gaps are MAR or NMAR rather than MCAR. Imputers trained and scored under MCAR are therefore optimized for the one regime that never occurs.

(C2) Gap length spans orders of magnitude. A trace contains both single dropped samples and multi-hour holes. Averaging error over a fixed masking protocol lets the rare long gaps dominate the

Curriculum-Aware Interpolate-then-Refine: Learned Physiological Time-Series Imputation under Realistic Missingness

mean, so a single score can rank a method first while it is strictly worse in the short-gap regime required in clinical practice.

We introduce Curriculum-Aware Interpolate-then-Refine (CAIR), a two-stage neural imputer designed around these two properties. Our key motivation is that the strength of classical interpolation is a starting point, not a ceiling: a coarse curve that respects the observed endpoints is straightforward to construct, and the challenge is to correct it toward physiological realism. A deterministic interpolant, however, fixes that starting point in advance: whatever it places inside a gap is a function of the two endpoints alone, which makes it accurate over a few missing samples but unable to express a multi-hour excursion. CAIR therefore learns the base curve rather than computing it. Stage 1 is a bidirectional GRU (Cho et al., 2014; Schuster & Paliwal, 1997) that predicts a base curve at every position from the observed values and the mask. Stage 2 is a Transformer encoder (Vaswani et al., 2017) that consumes this base curve (both as conditioning and as a residual), together with any other modalities the dataset provides, and corrects it over three successive refinement passes, each conditioned on the previous estimate.

To address (C1), CAIR is trained under a signal-agnostic random-gap curriculum that mixes scattered dropouts with contiguous blocks, rather than under the single masking pattern used at evaluation time. The training gap distribution proves as important as the architecture, which the name of the method reflects: the same network attains higher error than linear interpolation when trained on masks tailored to the physiology of a source domain, and lower error under all three mechanisms when trained on the broad curriculum (Sec. 4.6). To address (C2), we evaluate every method stratified by gap length and by missingness mechanism instead of reporting one average, and we show that the ranking of methods depends on the length regime, so a single averaged score cannot express it (Sec. 4.3).

Contributions. Our contributions are threefold:

• Methodologically, we propose CAIR, a two-stage imputer that replaces the deterministic interpolant with a jointly trained learned interpolator, and refines it with an iteratively unrolled Transformer. The design targets the two properties of physiological missingness above (C1, C2) rather than generic sequence modeling.

• Empirically, across two clinical domains, CGM from AI-READI (AI-READI Consortium, 2024) and arterial pressure from MIMIC-III (Johnson et al., 2016), CAIR attains the lowest reconstruction error of every method we evaluate under all three mechanisms, and its margin over the strongest baseline grows with difficulty: 9% under MCAR, 16% under MAR, and 19% under NMAR. The generic learned imputers that Toye et al. (2025) report as failures fail here too, which isolates how the model is designed and trained, rather than neural capacity, as the cause of the gain.

• Analytically, we show that low reconstruction error and faithful downstream clinical metrics are distinct axes. Interpolants that match the reconstruction error of CAIR fail to preserve the burden metrics clinicians read (linear interpolation recovers 0.14 of the recoverable burden on MIMIC-III), while tabular and neural imputers that do recover the burden incur 10–60% higher error. CAIR is the only method that ranks among the best on both axes.

References (43)