Manuscript Offprint

arXiv:2609.37848

Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case Study

Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even when it depends strongly on how the benchmark was evaluated. We study this problem on the widely used Kermany pediatric chest radiograph dataset using nine image classifiers and a controlled evaluation protocol. Under the same protocol, the eight pretrained backbones differ by only 0.026 AUROC. In contrast, changing whether the backbone is frozen or fine tuned changes AUROC by 0.044 on average, and changing the decision threshold changes balanced accuracy by 0.090 on average. The official test split is also measurably different from the training pool: a partition classifier distinguishes them at AUC 0.697, rising to 0.898 for normal radiographs. Most strikingly, a classifier using only file properties, with no image anatomy, reaches 0.992 balanced accuracy within the training pool but falls to 0.496 on the official test split. Validation fitted thresholds and calibration also transfer imperfectly. These results show that a high benchmark score can support different conclusions when the split, training policy, threshold, metric, calibration, and uncertainty are not communicated with it. We end with a seven item reporting recommendation in which each item is tied to an effect measured in the study.

1 Introduction

A biomedical machine learning paper is often remembered by one number. A reader may remember 98% accuracy or 0.97 AUROC long after the details of the experiment are forgotten. That number can then appear in related work, presentations, grant proposals, or discussions of clinical readiness. The problem is that the number is usually read as a property of the model, even though it also depends on how the model was evaluated.

Problem statement. Let fθf_{\theta} denote a trained classifier, D\mathcal{D} the dataset, and π\pi the evaluation protocol. The reported score is

s=S(fθ,π;D) ,(1)s=S(f_{\theta},\pi;\mathcal{D})\:, \tag{1}

where S is the scoring procedure. In this study, the protocol contains five choices that are common in biomedical image classification:

π=(σ⏟split,ϕ⏟backbonetraining,t⏟threshold,T⏟calibration,m⏟metric).(2)\pi=\left(\underbrace{\sigma}_{\mathrm{split}},\underbrace{\phi}_{\mathrm{backbone training}},\underbrace{t}_{\mathrm{threshold}},\underbrace{T}_{\mathrm{calibration}},\underbrace{m}_{\mathrm{metric}}\right). \tag{2}

40th Conference on Neural Information Processing Systems (NeurIPS 2026). Workshop: Responsible Communication of Machine Learning Research in Biomedicine.

Papers usually describe the architecture fθf_{\theta} in detail, but the elements of π\pi may be omitted, treated as defaults, or described only deep in the methods. If changing one element of π\pi changes the score as much as changing the architecture, then a headline score cannot be interpreted without the protocol that produced it.

We make that comparison explicit. For a fixed reference protocol π0\pi_0 and a set of architectures F\mathcal{F}, we define the architectural spread and the effect of changing one protocol component jj as

Δarch=max⁡f∈FS(f,π0;D)−min⁡f∈FS(f,π0;D),Δπ(j)=∣S(f,π;D)−S(f,π′;D)∣,(3)\Delta_{\mathrm{arch}}=\max_{f\in\mathcal{F}}S(f,\pi_{0};\mathcal{D})-\min_{f\in\mathcal{F}}S(f,\pi_{0};\mathcal{D}),\qquad\Delta_{\pi}^{(j)}=|S(f,\pi;\mathcal{D})-S(f,\pi^{\prime};\mathcal{D})|, \tag{3}

where π\pi and π′\pi' differ only in component j. Equation 3 gives the paper a simple question: are differences attributed to models larger than differences created by ordinary evaluation choices?

Case study. We study the pediatric chest radiograph dataset released by Kermany et al. [Kermany et al., 2018]. It is a useful case because it is public, small enough for controlled experiments, widely reused, and distributed with a fixed train and test split. Published studies report high performance on this corpus, often under evaluation setups that are not directly comparable [Stephen et al., 2019, Kundu et al., 2021, Siddiqi and Javaid, 2024]. Some preserve the official test split, while others pool the corpus and create a new split. Some freeze a pretrained backbone, while others fine tune it. Threshold selection and calibration are often not reported. These are exactly the choices represented by Eq. 2.

Main findings. First, under one fixed protocol, the eight pretrained backbones differ by only 0.026 AUROC, while changing whether the backbone is frozen or fine tuned changes AUROC by 0.044 on average and as much as 0.103. Second, the official test split is measurably different from the training pool. A partition classifier distinguishes the two at AUC 0.697, rising to 0.898 for normal radiographs. Third, a model that uses only file properties and no anatomy reaches 0.992 balanced accuracy within the training pool but only 0.496 on the official test split. This makes the risk of pooling and randomly re-splitting the corpus concrete. Fourth, thresholds and calibration fitted on validation data do not fully transfer to the official test distribution. These results are summarized in Table 2 and developed in Section 4.

Contribution to responsible communication. Our contribution is not a new pneumonia classifier and not a claim that this benchmark is unusable. It is a controlled case study of how the same biomedical benchmark can support different stories when the evaluation protocol is hidden. We connect each communication recommendation to a measured effect, rather than presenting a generic checklist. This directly addresses the gap between technical ML results and the claims that readers, clinicians, reviewers, and policymakers may take from them. Existing reporting guidance such as TRIPOD+AI already asks for many of these details [Collins et al., 2024]; our goal is to show, with measured examples, why those details change the meaning of the result.

References (28)