arXiv:2609.37855cs.CVSep 2026

Manuscript Offprint

arXiv:2609.37855

HandAnthro: Automated Hand Anthropometry from a Single Image

Fan Zhou, Shuairan Chen, Mengying Zhang, Yulin Wu, Sadegh Jafari, Sixing Yu, Rui Li, Ali Jannesari, Guowen Song

Abstract

Hand anthropometry supports protective-glove design, but existing measurement methods often require trained operators, specialized hardware, or manual landmarking. We present HandAnthro, which estimates 44 projected hand dimensions from a smartphone photograph of a palm-up hand on US letter-size paper. The pipeline reconstructs wrist-occluded paper boundaries for rectification, whitens non-hand pixels, and refines 41 anthropometry-specific landmarks from a fine-tuned You Only Look Once (YOLO) pose model using image-specific geometry and contours. Controlled evaluation comprised 720 captures from 45 held-out participants, each contributing 16 images across two smartphones, two backgrounds, two angles, and two nominal illumination settings. HandAnthro produced complete outputs for 704 captures (97.8%); among these, mean absolute error (MAE) was 3.80 mm per dimension against two trained operators' caliper measurements. Regional MAEs were 2.48 mm for non-thumb fingers, 6.04 mm for thumbs, and 6.17 mm for palm and wrist. In a researcher-assisted mobile-app pilot, automated batch processing returned all 44 dimensions for 260 of 268 retained, researcher-screened firefighter images (97.0%). A descriptive, unpaired comparison with an independent national firefighter reference yielded a mean absolute difference of 2.40 mm across 28 sex-by-dimension group-mean contrasts. These results characterize controlled measurement performance and researcher-assisted field feasibility for future distributed hand-anthropometry studies.

1 Introduction

Acute occupational hand injuries account for more than one million US emergency-department visits annually, and protective gloves reduce their relative risk by about 60% (Sorock et al. 2004a,b). This protection depends on fit: poor fit compounds losses in dexterity, tactile sensitivity, and grip strength and reduces user acceptance (Dianat, Haslegrave, and Stedmon 2012; Griffin et al. 2018b). Yet glove-sizing systems often rely on outdated or unrepresentative hand data (Hsiao et al. 2015, 2026). Large, current anthropometric samples are therefore valuable for glove and hand-tool design, but direct caliper measurement requires trained operators, manual photogrammetry requires work on each image, and three-dimensional (3D) approaches require scanners or calibrated multi-view hardware (Griffin et al. 2018a; Yu et al. 2013; Yang et al. 2021).

Prior automated two-dimensional (2D) hand-measurement systems have typically relied on tightly controlled acquisition setups, such as flatbed scanners or calibrated industrial-camera rigs (Han and Park 2016; Nguyen, Le, and La 2025). HandAnthro instead uses a simple smartphone protocol in which a palm-up, finger-spread hand is photographed on a letter-size paper sheet. The workflow uses the sheet geometry to rectify the image and recover metric scale, then localizes the anatomical endpoints needed to compute 44 projected dimensions. By reducing on-site equipment requirements and enabling an automated image-to-measurement workflow without manual involvement, this design targets two major operational barriers to larger, geographically distributed occupational hand-anthropometry studies. First, the system must recover a reliable paper reference despite wrist occlusion and camera viewpoint variation. Second, it must accurately localize measurement endpoints on the true hand contour despite unpredictable shadow patterns around the hand boundary caused by variations in real-world illumination and capture conditions.

HandAnthro addresses the first problem by reconstructing the occluded paper mask before quadrilateral detection. It addresses the second by whitening the non-hand pixels, fine-tuning a You Only Look Once (YOLO) pose architecture (Jocher, Chaurasia, and Qiu 2023; Jocher and Qiu 2024) to predict anthropometry-specific landmarks, and refining those predictions with image-specific finger geometry and contour constraints. These stages automatically produce the protocol-defined projected measurements without participant-specific calibration.

We evaluate HandAnthro in two complementary studies. A controlled repeated-capture study quantifies perspective-rectification and end-to-end completion, caliper-referenced measurement accuracy, and sensitivity across the tested capture conditions. A separate researcher-assisted mobile-app field pilot evaluates completion outside the capture rig and compares sex-specific group means with corresponding hand-anthropometry summaries from an independent national firefighter cohort. Because the cohorts are independent, this comparison assesses population-level plausibility rather than individual-level measurement accuracy.

∗^{*}Corresponding author.

References (29)