arXiv:2609.35405cs.CVSep 2026

Manuscript Offprint

arXiv:2609.35405

Reduce, Then Encode: Multiscale Volumetric Reduction for 2D Foundation Models in Brain MRI

Dexuan Ding, Yuankai Qi, Bogong Wang, Luping Zhou, Amin Beheshti

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

ABSTRACT

Pretrained 2D foundation models offer a practical alternative to dedicated 3D pretraining for brain structural magnetic resonance imaging (sMRI), but their use on volumetric data requires bridging the mismatch between a 2D encoder and a 3D volume input. Existing methods typically encode slices independently and integrate their features afterwards. We introduce Multiscale Volumetric Reduction (MVR), a reduce-then-encode approach that compresses each anatomical view from D slices into M≪DM \ll D complementary 2D components before foundation-model encoding. MVR combines an uncentered-PCA base component derived from the original through-plane intensities with residual detail components constructed from multiscale spatial descriptors. The reduction is estimated from the training volumes without diagnostic labels or gradient-based optimization and remains fixed thereafter. The resulting components are independently processed by a shared frozen 2D foundation model and concatenated for linear probing. Under this frozen-encoder setting, MVR achieves strong overall performance across ADNI, OASIS, and ABIDE relative to the evaluated 2D-to-3D adaptation methods and simple input-reduction baselines, while also generalizing strongly from ADNI to AIBL.

1 INTRODUCTION

Brain structural magnetic resonance imaging (sMRI) provides a non-invasive view of brain anatomy and is widely used to study structural alterations associated with neurological and neurodevelopmental disorders (Tak et al., 2026; van Rooij et al., 2018). Unlike ordinary 2D images, an sMRI scan is represented as a three-dimensional volume, where anatomical and disease-related variations may extend across multiple slices and spatial scales. Effective analysis therefore requires preserving informative volumetric structure while extracting features useful for downstream prediction.

A direct solution is to learn representations from 3D medical volumes themselves. Recent medical foundation models such as BrainIAC (Tak et al., 2026), BrainMVP (Rui et al., 2025), and 3DINO (Xu et al., 2025) demonstrate the effectiveness of large-scale volumetric pretraining, but require dedicated 3D architectures and substantial medical imaging data (Fig. 1(a)). An attractive alternative is to reuse general-purpose 2D vision foundation models pretrained on large and diverse image collections. Although their pretraining domain differs substantially from medical imaging, recent studies have shown that their representations can still transfer effectively to volumetric medical imaging (Rafsani et al., 2025). RAPTOR (An et al., 2025), for example, constructs volumetric embeddings using a frozen 2D foundation model (DINOv2 (Oquab et al., 2024)), while AnyMC3D (Liu et al., 2026) further improves transfer through lightweight adaptation and learned aggregation. These results suggest that general-purpose 2D foundation models can provide useful representations for medical volumes without requiring dedicated volumetric pretraining.

∗^{*}Corresponding author

(a) Medical FM pretraining (e.g., BrainIAC, BrainMVP, 3DINO)

Trainable Frozen

Figure

(b) Reduction after encoding (e.g., RAPTOR, AnyMC3D)

Figure

(c) MVR: reduction before encoding

Figure

Figure 1: Comparison of volumetric representation strategies for brain MRI. (a) Medical foundation models learn volumetric representations through dedicated 3D pretraining. (b) Approaches based on pretrained 2D foundation models encode D selected 2D slices independently and integrate the resulting features after encoding, with method-specific adaptation where applicable. (c) Our MVR instead performs reduction in the input space, transforming each volume into M≪DM \ll D dense 2D components before encoding with a shared frozen 2D foundation model. The resulting component features are concatenated to form the volume representation. ↓\downarrow and ↓\downarrow denote trainable and frozen modules.

However, a remaining challenge is the mismatch between a 2D encoder and a 3D volume. A 2D foundation model processes one two-dimensional input at a time (Fig. 1(b)), whereas an MRI scan contains a spatially ordered sequence of slices. Existing approaches commonly address this mismatch through an encode-then-integrate strategy: slices are first encoded independently, after which their features are pooled, projected, attended to, or otherwise aggregated into a volume-level representation. RAPTOR (An et al., 2025) reduces independently extracted slice features through pooling and random projection, while AnyMC3D (Liu et al., 2026) combines slice-wise encoding with learned feature aggregation. In this paradigm, cross-slice information is incorporated only after slice-level feature extraction. When the 2D encoder is frozen, however, its slice-level representations cannot adapt to facilitate subsequent volumetric aggregation. This raises the possibility that preserving cross-slice structure in the encoder inputs themselves may provide a more effective inductive bias than relying exclusively on post-encoding integration. This motivates us to instead integrate volumetric information before encoding.

To this end, we introduce Multiscale Volumetric Reduction (MVR), a reduce-then-encode approach that transforms each anatomical view from D slices into M≪DM \ll D dense 2D components before foundation-model encoding (Fig. 1(c)). The key challenge is to achieve substantial through-plane reduction without collapsing useful volumetric variation. Simple averaging can suppress localized structure, while a single linear projection provides only one summary of the through-plane intensity pattern. MVR therefore adopts a base-and-detail construction. A base component projects the original through-plane intensities onto a shared direction estimated by uncentered PCA, providing a compact reference derived from the original volume. To retain complementary information beyond this single projection, MVR constructs multiscale descriptors from differences between Gaussian-smoothed slices, incorporating in-plane context at multiple spatial scales while preserving the complete through-plane sequence. After removing variation linearly associated with the base component, PCA of the residual descriptors produces M−1M - 1 detail components capturing dominant complementary variation. The reduction operators are data-adaptively estimated from the training volumes without diagnostic labels or gradient-based optimization and remain fixed thereafter. Each component is independently processed by the same frozen 2D foundation model, and the resulting features are concatenated across components and anatomical views to form the final volumetric representation.

Figure

Figure 2: Main architecture of our Multiscale Volumetric Reduction (MVR). (a) Base component extraction summarizes the original through-plane intensities into a dense base component and sampled base scores. (b) Multiscale residual expansion incorporates in-plane variation at multiple scales and produces M - 1 complementary detail components after accounting for the base reference. (c) Encoding and classification applies MVR to the axial, coronal, and sagittal views, independently encodes the resulting components with a shared frozen 2D foundation model, and concatenates their features for classification.

We evaluate MVR on Alzheimer's disease classification using ADNI and OASIS-3, autism classification using ABIDE, and external ADNI-to-AIBL evaluation. With a frozen DINOv3 encoder and a linear classifier, MVR achieves strong overall performance relative to the evaluated 2D-to-3D adaptation methods and simple input-reduction baselines across ADNI, OASIS, and ABIDE. Ablation studies further show that the multiscale construction and the combination of base and detail components contribute consistently to classification performance.

Our main contributions are threefold:

• We introduce a reduce-then-encode strategy for adapting frozen 2D foundation models to volumetric brain MRI, incorporating information across slices before rather than only after 2D feature extraction.

• We develop MVR, a data-adaptive and gradient-free base-and-detail reduction that converts D slices into M≪DM \ll D complementary 2D components by combining through-plane reduction with multiscale in-plane context.

• We demonstrate the effectiveness of MVR across multiple brain-MRI cohorts and diagnostic tasks, including external ADNI-to-AIBL evaluation, and show through ablation that its multiscale construction and base-detail decomposition consistently contribute to classification performance.

References (18)