Abstract

Deep-learning models of anatomy can be numerically plausible yet anatomically impossible, and they generalize poorly when data are scarce. We introduce Anatomy-Informed Neural Networks (AINN), in which soft anatomic priors enter as penalty terms in the loss (e.g., a branching penalty that treats a renal transplant artery off the iliac instead of the aorta as unexpected rather than impossible), in direct analogy to a physics-informed neural network, and hard anatomic priors (e.g., continuity of the vessel) are built into the architecture and state representation, making such invalid predictions impossible by construction wherever the prior admits architectural enforcement.

We develop it on a clinical test case with limited data: how the aortoiliac tree deforms when a stiff wire is introduced endoluminally. This is important to contemporary aortic surgery and will matter to autonomous endovascular navigation. We lift the vessel centerline and the wire path from R3\mathbb{R}^{3} to curves of frames in the Lie group SE(3)\mathrm{SE}(3), and couple a Cosserat-rod wire to a tortuosity-modulated, anatomically anchored vessel through a unilateral lumen-contact inequality. The prediction is a constrained minimizer of the coupled elastic energy, with contact forces as its Lagrange multipliers. Supervision is a Wasserstein-2 optimal-transport loss between the predicted projection through the C-arm geometry and the observed angiogram, so a 2D angiogram can train a 3D prediction. The kinematics, loss and projection are verified against known ground truth; the mechanics solver only against its own optimality conditions, and predicted displacement is not yet mesh-converged. Here, no network is trained. Future work will transfer this in silico model to real CT scans and test whether it improves predictive accuracy and reduces the training data required.

Keywords: anatomy-informed neural networks; physics-informed learning; endovascular robotics; robotic navigation; EVAR; TEVAR; vascular deformation; optimal transport; SE(3)\mathrm{SE}(3); Lie algebra; Wasserstein distance; obstacle problem; variational inequality.

1 Introduction

Deep learning dominates medical image analysis, yet two limitations persist in surgical and interventional settings. Models that segment, register, or predict anatomy can produce outputs that are numerically plausible but anatomically impossible [1, 2], such as a vessel branching from the wrong parent or a structure leaving the body. Annotated datasets for a given procedure are also small [3], so a network trained from scratch on a few dozen cases generalizes poorly. Both failures arise because the model must learn anatomic structure implicitly from data rather than being told the structure it must respect.

Physics-informed neural networks (PINNs) [4, 5] address the analogous problem in the physical sciences by writing a system’s governing equations directly into the training loss, rewarding the network for obeying known physics rather than rediscovering it. We propose the anatomic counterpart. An Anatomy-Informed Neural Network (AINN) encodes prior knowledge of anatomic structure into the model (Figure 1), both softly through penalty terms in the loss, in direct analogy to the physics residuals of a PINN, and as hard constraints built into the architecture and state representation, so that whole classes of anatomically invalid prediction are impossible by construction rather than merely discouraged. These priors span topology, mobility, symmetry, shape, atlas-relative position, and contact, and AINN provides a common framework for assembling them. The soft route matters because anatomy varies. Priors learned from a population that includes rare variants treat an unusual configuration as improbable rather than forbidden, so an autonomous system is not caught off guard by anatomy it has effectively already seen (§2.2).

We develop the paradigm on a concrete, clinically consequential problem in endovascular surgery. Aortic stent grafts are planned on a preoperative computed tomography (CT) angiogram treated as a fixed map of the patient’s anatomy. The vascular tree, however, is compliant, and when a stiff guidewire is advanced the aorta straightens, the iliac arteries foreshorten, and branch-vessel ostia migrate [6, 7, 8]. The preoperative configuration, which we call State 1, is thus replaced intraoperatively by a deformed configuration, State 2, in which the device is deployed. Each subsequent maneuver produces a further state, State 3, State 4, and so on, each predictable from the preceding one given prior knowledge of how that maneuver reshapes the surrounding anatomy. This geometric infidelity can compromise sealing-zone assessment and branch-vessel cannulation, and it becomes a fundamental obstacle as procedures move toward semi-autonomous robotic navigation, where a controller guided by a State 1 map aims at anatomy that no longer exists at that location.

Predicting State 2 from State 1 is a demanding test of the AINN idea. The wire is not the deformed vessel centerline. Because its radius is much smaller than the lumen, it rides the inner curvature and takes the chord across bends, so models that assume wire and vessel center coincide are structurally wrong. The vessel’s resistance to deformation is heterogeneous and anatomically anchored, the intraoperative ground truth is typically a single two-dimensional angiogram rather than a second CT, and a realistic single-center cohort numbers only a few dozen paired cases. A useful predictor must therefore respect the geometry of a thin stiff structure in a curved compliant tube, learn from two-dimensional supervision, and remain data-efficient.

This problem has been studied before using finite-element methods that mesh the arterial wall [6, 9, 10, 8, 11, 12]. We take the centerline-with-frames as the primitive object rather than as a quantity derived from a mesh (§3), which places the state space in the Lie group SE(3)\mathrm{SE}(3).

Our instantiation combines four components in a configuration we have not found applied to this problem. Every vessel and wire frame is an element of SE(3)\mathrm{SE}(3), which separates curves that are close in space but differently oriented and guarantees valid rigid-body configurations. A Cosserat-rod wire is coupled to a tortuosity-modulated, anatomically anchored vessel through a unilateral lumen-contact constraint, so the equilibrium reproduces the clinically observed bowstring deformation and apex-concentrated wall loading. Supervision uses a Wasserstein-2 optimal-transport loss between measures of frames, pushed through the C-arm projection so a single view can supervise a three-dimensional prediction. An SE(3)\mathrm{SE}(3)-equivariant residual network composed with the physics model realizes the map, so the physics does most of the work and the network learns only a residual correction.

None of the four is new on its own [13, 14, 15, 16, 17, 2, 18, 19, 20]. §11 sets out what we do and do not claim.

This paper makes four contributions. It defines AINN as a methodological paradigm with an explicit parallel to physics-informed learning, and organizes anatomic priors into categories that make the hard-versus-soft design decision explicit, identifying the mobility and anchoring prior as the category we could not find in existing taxonomies (§2). It formulates stiff-wire vascular deformation as a coupled variational problem on SE(3)\mathrm{SE}(3) with a unilateral lumen contact, a tortuosity-anchored stiffness field, and an optimal-transport loss (§4–§9). It reports a numerical verification of these components on synthetic problems with known ground truth, including a wire-stiffness sensitivity analysis that identifies which conclusions are robust and which are not (§10). And it sets out what separates the verified framework from clinical deployment (§11).

References (43)