arXiv:2609.35726cs.CVSep 2026

Manuscript Offprint

arXiv:2609.35726

Impact of Patient Orientation in Single- and Multi-View Camera Environments for AI-based Rehabilitation Monitoring

Miriama Jánošová, Andreas Lang, Petra Budikova, Jan Sedmidubsky

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original. This text is shared under the same licence.

Abstract

Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data. Although numerous RGB-based pose estimation methods have been proposed, the impact of camera placement on detecting clinically relevant movement errors remains insufficiently explored. To address this gap, we introduce REHAB26-ViewAngles, a dataset comprising correct and incorrect rehabilitation exercise executions captured from a wide range of camera angles. Furthermore, we propose a novel separability metric to quantify an algorithm's ability to distinguish between valid and faulty exercise repetitions. Using these tools, we analyze how various RGB-based pose-estimation strategies are suitable for exercise quality assessment under varying camera placements. In particular, we analyze single-camera 2D and 3D pose estimation and four multi-camera strategies: a combination of two orthogonal 2D views, 3D triangulation, weighted 3D fusion, and an AI-based pose-estimation transformer model specifically trained from two synchronized cameras. Our findings reveal that an optimally placed 2D camera can improve the separability by 16.9% over the commonly used 0° frontal view and frequently outperforms single-camera 3D estimation, while combining two views can further improve accuracy by up to 13.1%. These results offer practical guidance for deploying rehabilitation monitoring in both home and clinical settings.

Keywords— multi-view pose estimation, skeleton sequence, rehabilitation exercise, human body keypoint, camera viewpoint, motion features, exercise quality assessment, exercise similarity

1 Introduction

The demand for physiotherapy and rehabilitation is steadily increasing, driven by aging populations and the rising prevalence of musculoskeletal disorders (Gimigliano, Negrini, et al., 2017). At the same time, a shortage of trained physical therapists has accelerated the transition toward home-based and minimally supervised rehabilitation. In such settings, patient improvements depend not only on whether exercises are performed, but also on how accurately they are executed, as even small deviations or compensatory movements can reduce therapeutic effectiveness (Argent, Daly, and Caulfield, 2018; Zhang, Tian, He, Xu, Wang, Huang, Yi, and Liu, 2022).

*Corresponding author. E-mail: m.janosova@mail.muni.cz. ORCID: 0009-0008-4807-1023.

†^{\dagger}E-mail: andreas.lang@tu-dortmund.de. ORCID: 0000-0003-3212-5548.

‡^{\ddagger}E-mail: budikova@visioncraft.cz. ORCID: 0000-0003-1523-1744.

§Corresponding author. E-mail: sedmidubsky@mail.muni.cz. ORCID: 0000-0002-7668-8521.

Recent advances in AI-driven computer vision enable new forms of rehabilitation support outside traditional clinical environments, particularly in home-based and minimally supervised settings (Bonato, Feipel, Corniani, Arin-Bal, and Leardini, 2024; Park, Chung, and Park, 2022). Modern pose estimation methods (Dubey and Dixit, 2023; Sardari, Sharifzadeh, Daneshkhah, Nakisa, Loke, Palade, and Duncan, 2023; Jocher, Qiu, Liu, Lyu, Akyon, and Kalfaoglu, 2026; Nogueira, Oliveira, and Teixeira, 2025) can extract skeletal representations from standard RGB video in real time on consumer smartphones, providing positions of joints in either 2D (measured in pixels of video) or estimated 3D (measured in virtual meters) space. Such skeleton data can be used to evaluate rehabilitation correctness, measure progress, and provide general guidance for patients during home rehabilitation.

Skeleton-based analysis of movement correctness has gained increasing attention across a variety of application domains, including sports training and fitness exercise (Zhou, Cai, Wang, Shum, and Liang, 2026). In these settings, user's movements are typically represented as skeletal joint sequences and evaluated against a pre-trained model of the target exercise. However, physical rehabilitation presents additional challenges, as safe and effective therapy must account for each patient's individual capabilities, limitations, and recovery progress. Consequently, universal motion models are generally insufficient for rehabilitation monitoring, necessitating the use of personalized models that capture patient-specific movement patterns.

References (50)