Manuscript Offprint

arXiv:2609.30928

UltraG-Bench: A Multi-task Benchmark for assessing Large Vision-Language Models on Pixel-level Evidence Grounding in Ultrasound

Quanhao Zhu, Bo Xu, Rui Lin, Chenyuan Wang, Yu Shao, Boling Zhu, Jiuyan Sun, Liang Zhao, Hongfei Lin, Feng Xia

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Quanhao Zhu, Bo Xu, Rui Lin, Chenyuan Wang, Yu Shao, Boling Zhu, Jiuyan Sun, Liang Zhao, Hongfei Lin

Dalian University of Technology

zhuqh19@gmail.com

boxu@dlut.edu.cn

lr983088162@mail.dlut.edu.cn

chenyuanwang@mail.dlut.edu.cn

python@mail.dlut.edu.cn

SinsapZ@outlook.com

2093145195@mail.dlut.edu.cn

liangzhao@dlut.edu.cn

hflin@dlut.edu.cn

Feng Xia

RMIT University

f.xia@ieee.org

ABSTRACT

Ultrasound is one of the most widely used medical imaging modalities, and recent large vision-language models(VLMs) have shown increasing capabilities in ultrasound image understanding. However, these models fail to provide pixel-level visual evidence aligned with their semantic predictions, and their fine-grained grounding capability in ultrasound remains largely unclear. We introduce UltraG-Bench, a large-scale multi-task benchmark for evaluating pixel-level evidence grounding in ultrasound. UltraG-Bench is built by annotating 40 public ultrasound segmentation datasets spanning 13 anatomical categories, and comprises three progressive tasks: instruction-guided segmentation, evidence-grounded VQA, and evidence-grounded report generation, with 331125, 666779, and 138832 annotations, respectively. Comprehensive evaluation of 14 state-of-the-art models reveals a substantial gap between semantic understanding and fine-grained pixel-level localization. We further propose UltraG-Agent, which combines the semantic reasoning capabilities of a VLM with the ultrasound-specific segmentation capability of UltraSAM3. Experiments show that UltraG-Agent substantially improves both semantic prediction and pixel-level visual grounding. Our dataset and code are available at https://github.com/zhuqh19/UltraG-Bench.

1 Introduction

Ultrasound has become one of the most widely used medical imaging modalities in clinical practice owing to its lack of ionizing radiation, real-time imaging capability, and relatively low cost. Compared with CT and MRI, ultrasound devices are more portable and less expensive, making them highly accessible across diverse clinical settings [1][1]. Accurate recognition, localization, and interpretation of anatomical categories and lesions in ultrasound images are fundamental to clinical diagnosis and decision-making [2][2].

Nowadays, supervised segmentation methods and general foundation models have continuously improved pixel-level localization of organs and lesions [3, 4]. On the other hand, vision-language models (VLMs) and multimodal large language models (MLLMs) are increasingly being applied to ultrasound image understanding, including tasks such as visual question answering (VQA) and report generation [2]. However, a substantial gap remains between pixel-level visual localization and high-level semantic understanding in current models. Conventional segmentation models can provide precise spatial boundaries but generally lack open-ended language understanding and semantic generation capabilities, whereas VLMs and MLLMs can answer questions or generate image descriptions but often fail to provide pixel-level visual evidence that is aligned with their semantic predictions [5, 6, 7, 8]. This gap is particularly critical in medical applications, where clinical reasoning depends not only on “what the model predicts”, but also on “which regions in the image support that prediction.” However, this gap has not yet been systematically evaluated by existing benchmarks, leaving the extent of the disconnect between semantic understanding and pixel-level visual grounding in current models poorly understood.

Figure

Figure 1: Overview of UltraG-Bench, including 13 anatomical categories, benchmark statistics, and representative examples of the three tasks: Instruction-guided Segmentation, Evidence-grounded VQA, and Evidence-grounded Report Generation.

Existing benchmarks often evaluate semantic understanding and pixel-level visual localization in isolation [9, 10, 11, 12, 13]: segmentation benchmarks primarily measure the overlap between predicted and ground-truth masks using metrics such as IoU and Dice, whereas VQA and report-generation benchmarks mainly assess the correctness of the generated answers or text. As a result, a model may produce the correct answer while relying on the wrong visual region, or generate fluent and semantically plausible descriptions without providing consistent pixel-level evidence for its claims. Recently, visual evidence-grounded datasets such as GEMeX [14] and MIMIC-ILS [15] have emerged, but such evaluation remains lacking in ultrasound, especially at the pixel level.

To address these challenges, we introduce UltraG-Bench as shown in Figure 1, a large-scale multi-task benchmark for Pixel-level Evidence Grounding in ultrasound. UltraG-Bench annotates 40 public ultrasound segmentation datasets spanning 13 anatomical categories, including the abdomen, breast, heart, carotid artery, fetus, kidney, liver, lung, muscle, nerve, ovary, prostate, and thyroid, comprising 138,832 ultrasound images and 181,952 segmentation masks. Based on these pixel-level annotations, we construct three tasks from visual perception to semantic understanding: instruction-guided segmentation, which evaluates whether a model can localize the correct target from a natural-language instruction; evidence-grounded VQA, which assesses answer correctness and the accuracy of the corresponding visual evidence; evidence-grounded report generation, which examines whether a model can consistently associate different semantic statements with the appropriate pixel-level regions during report generation. During dataset construction, we explicitly preserve the correspondence between textual statements and the original segmentation masks, while restricting diagnostic, pathological, and treatment-related claims that are unsupported by the available pixel-level annotations, thereby ensuring that each grounded statement is backed by traceable visual evidence. Based on this benchmark, we systematically evaluate 15 state-of-the-art models, including closed-source general-purpose MLLMs, open-source general-purpose MLLMs, medical MLLMs, and pixel-level grounded medical MLLMs.

Furthermore, we observe a clear complementarity between high-level semantic understanding and fine-grained pixel localization in existing models: MLLMs excel at interpreting complex natural-language instructions and generating semantic responses, whereas specialized ultrasound segmentation models provide stronger pixel-level structural localization. This motivates a further question: Can more reliable Pixel-level Evidence Grounding be achieved through collaboration among pretrained models? To explore this, we construct UltraG-Agent, an ultrasound grounding agent that uses an open-source MLLM for instruction understanding, task planning, and response generation, while employing UltraSAM3 [16], an ultrasound concept-driven segmentation model, as the visual module for target segmentation. Experiments show that UltraG-Agent achieves state-of-the-art performance on UltraG-Bench.

The main contributions are as follows:

  • UltraG-Bench: We annotate 40 public ultrasound segmentation datasets spanning 13 anatomical categories, comprising 138,832 ultrasound images and 181,952 segmentation masks. We construct three tasks, including instruction-guided segmentation, mask-grounded VQA, and mask-grounded report generation, to evaluate capabilities of existing models.

  • Comprehensive evaluation: Under a unified evaluation framework, we benchmark 16 state-of-the-art models, including closed-source and open-source general MLLMs, medical MLLMs, pixel-level grounded medical MLLMs, and prompt-driven segmentation models.

  • UltraG-Agent: We propose an ultrasound agent framework that combines the instruction understanding and task-planning capabilities of an open-source MLLM with the specialized ultrasound segmentation capability of UltraSAM3. UltraG-Agent achieves state-of-the-art performance among all evaluated models.

References (64)