arXiv:2609.30989cs.CVSep 2026

Manuscript Offprint

arXiv:2609.30989

PICO: Projection-Informed Consistency Optimisation for 6DoF Surgical Tool Pose Estimation

Lucy Fothergill, Pietro Valdastri, Dominic Jones, Duygu Sarikaya

Abstract

Purpose: Accurate 6 DoF pose estimation of surgical tools is critical for automation, robotic proprioception, and safe interaction with the tissue operated on. Kinematics-based approaches suffer from accumulated errors due to the cable-driven nature of robotic arms, while vision-based methods often rely on external markers or trackers. Although more recent vision-based advances have been proposed, these two-stage pose estimation methods often lack real-time robustness due to accumulated errors and computational overhead.

Methods: We propose a novel end-to-end trainable model, PICO. Our model employs a multi-task learning architecture to predict segmentation and depth maps, alongside regression of translation and rotation parameters. We define two proxy tasks that enforce geometric consistency in both 2D and 3D spaces, improving accuracy and robustness. For this, we propose a projection loss, and a point-to-point loss.

Results: We evaluate our method on the SurgRIPE dataset, benchmarking its performance against state-of-the-art approaches using standard 6DoF pose estimation metrics. Our results demonstrate consistently strong performance across all four subsets, specifically in rotation, ranking second even under occlusion. It also demonstrates comparable translational performance, remaining competitive, especially in occluded cases.

Conclusion: PICO demonstrates the effectiveness of multi-task learning and geometry-aware proxy tasks for robust and reliable surgical tool pose estimation, especially in occluded scenarios, highlighting potential for future applications.

Keywords: Surgical Tool Pose Estimation, 6DoF Pose Estimation, Proxy Task, Multi-Task Learning

1 Introduction

Autonomous robotic surgery requires safe interaction with the surgical environment. A fundamental aspect of this is accurate positional knowledge of surgical tools, which is necessary for preoperative planning and the prevention of adverse tool-tool or tool-tissue interactions, and providing real-time feedback in response to changes in the environment. Current da Vinci®Surgical Systems (dVSS) estimate 6D pose of surgical tools with forward kinematic equations that rely on joint angle measurements of the robotic arm and known linkage parameters. Kinematics-based pose is not sensitive enough for autonomy, with discrepancies of up to 1.02mm, most noticeably in the end effector pose, arising due to cable-slack, pulley-cable friction and accumulation of errors across multiple joints [1]. Such inaccuracies are unacceptable in a surgical setting, as even small errors can lead to unintended incisions and damage to critical structures such as nerves or blood vessels. Therefore these limitations could be addressed with vision-based methods, which provide direct perception of the scene and have the potential to adapt to dynamic situations where conditions change, such as tissue deformation or unexpected events. The use of external markers and trackers in a surgical setting are impractical and potentially dangerous. Attaching markers to tools requires additional time-consuming procedures such as preoperative sterilisation which interrupts surgical workflow [2]. Additionally, methods which rely on external markers demand a clear line of sight between the camera and marker, which can not be guaranteed in a surgical environment due to occlusion from blood, tissue, smoke or other instruments [3]. For these reasons, markerless methods are preferable.

A major challenge in 6D surgical tool pose estimation is the lack of ground truth pose annotations for surgical images. To address this, many existing methods [4–7] avoid directly predicting the 6D pose and instead rely on multi-stage approaches that use more readily available geometric information to supervise intermediate predictions. These intermediate representations, such as keypoints are first predicted, and the 6D pose is then estimated using methods such as Perspective-n-Point (PnP), template matching, or rendering-based approaches. Alternatively, an initial pose can be estimated and subsequently refined iteratively. These multi-stage pipelines can struggle with real-time performance due to sensitivity to noise, accumulated errors and computational overhead. The accuracy depends on the quality of the 2D-3D correspondences which may be noisy or inaccurate. Moreover, if the initial pose estimation is inaccurate, the refinement step may not be able to fully correct it. Iterative refinement methods are also known to be slow. During inference, two-stage methods that first estimate 2D features and then apply Perspective-n-Point (PnP) or other refinement techniques may introduce delays. The iterative nature of pose refinement can be time-consuming at inference time, degrading the models performance for dynamic surgical settings. For methods relying on generating 2D-3D correspondences at inference time or rendered images, the complexity of the calculations can significantly impact inference speed. In this work, we propose a novel end-to-end trainable model, PICO: Projection-Informed Consistency Optimisation for 6DoF Surgical Tool Pose Estimation. PICO leverages a multi-task learning architecture to simultaneously predict segmentation and depth maps, while also regressing translation and rotation parameters. We then define two proxy tasks that enforce geometric consistency in both 2D and 3D spaces, improving accuracy and robustness. First, we propose using a projection-based loss, which enforces geometric consistency between predicted pose and the predicted tool segmentation. This ensures that the model maintains spatial consistency through alignment of 2D observations and 3D model representations. The projection-based loss encourages the model to learn geometrically consistent representations, leading to a more accurate pose estimation. Discrepancies between the model's projection and predicted segmentation lead to penalisation in the loss function, which helps improve pose estimation accuracy during training, as the model learns to generate more accurate pose estimations for surgical tools. Similarly, we define a point-to-point loss, where the predicted and ground truth pose transformations are applied to the 3D model points, and the root mean squared error (RMSE) between corresponding points is minimised to promote 3D consistency. An overview of our method is shown in Figure 1.

We evaluate our method on the SurgRIPE dataset [4], comparing its performance against existing approaches using standard 6DoF pose estimation metrics. Across all four test datasets, our end-to-end trainable model PICO ranks second in rotational accuracy even under occlusion. It also demonstrates comparable translational performance, remaining competitive, especially in occluded cases. These results highlight the effectiveness of our geometric consistency approach, enforced through our projection and point-to-point proxy tasks.

Figure

Fig. 1: Proposed training framework Given an input RGB image, the tool is first cropped, resized and fed into a U-Net style architecture with a ResNet-50 encoder backbone. The learned features are fed into a decoder and subsequently pass through separate depth and segmentation heads. Simultaneously, the encoder features are passed through linear layers and regression heads for pose estimation. The estimated pose is used to transform the 3D tool model, and both the 2D projection and 3D representation of the tool are minimised through two defined proxy tasks. All losses are optimized jointly with the multi task loss function.

References (32)