Manuscript Offprint

arXiv:2609.31524

Structured Reasoning Agentic Framework for Interpretable Critical View of Safety Assessment

Qing Xu, Yuxiang Luo, Zhen Chen

Qing Xu 1∗^{1*}, Yuxiang Luo 2∗^{2*}, and Zhen Chen 2(⊗)^{2(\otimes)}

1^{1} School of Computer Science, University of Nottingham, UK

2^{2} Department of Data Science and Artificial Intelligence,

The Hong Kong Polytechnic University, Hong Kong SAR

z.chen@polyu.edu.hk

Abstract. Surgical scene understanding is critical for computer-assisted intervention, yet laparoscopic cholecystectomy remains challenged by the complex anatomy of the hepatocystic triangle and the risk of bile duct injury. Existing methods for Critical View of Safety (CVS) assessment typically treat it as a holistic prediction task, mapping visual features directly to criterion-level labels. This black-box paradigm lacks explicit reasoning about anatomical relationships, limiting both interpretability and compositional generalization. To address this, we propose ReasonCVS, a structured reasoning agentic framework empowered by Vision-Language Models (VLMs) that decomposes CVS assessment into explicit, fine-grained anatomical verification. Specifically, we devise an Anatomical Scene Graph Abstraction (ASGA) that organizes anatomical entities and their spatial relationships into a structured representation. To operationalize this, we introduce a Rationale-Aware Reasoning Agent, powered by a Large Language Model (LLM) fine-tuned via rationale distillation. Functioning as a strict central decision-maker, it invokes VLM-driven Sub-criterion Verifier as a specialized perceptual tool to parse the graph and independently evaluate individual sub-criteria. Through calibrated soft reasoning, this agent synthesizes the tool-gathered distributed observations, yielding a final verdict alongside a traceable clinical rationale. Extensive experiments on the Endoscapes-CVS201 benchmark demonstrate that ReasonCVS achieves superior performance (68.1% mAP) over state-of-the-art while providing interpretable, criterion-level explanations for reliable surgical assessment.

Keywords: Laparoscopic Cholecystectomy · Critical View of Safety · Agentic Reasoning · Interpretable Assessment.

1 Introduction

Surgical scene understanding plays a crucial role in computer-assisted intervention and has received extensive attention in the research [8, 7, 4]. Particularly, laparoscopic cholecystectomy is challenged by the complex anatomy of the hepatocystic

  • Equal contribution.

Q. Xu et al.

Figure

Fig. 1. Comparison of existing methods and our ReasonCVS for CVS assessment. (a) Existing methods map visual features directly to criterion-level labels for holistic prediction. (b) Our ReasonCVS abstracts the surgical scene into an anatomical scene graph and invokes sub-criterion Verification for interpretable assessment.

triangle and the need to accurately identify critical structures to prevent bile duct injury [19, 23]. These requirements have motivated a key safety task in the field, i.e., automated Critical View of Safety (CVS) assessment [18, 2].

Early works on CVS assessment formulated the problem as image-level classification, predicting criterion satisfaction directly from individual surgical frames [11, 21], yet such frame-wise approaches prove insufficient to capture the anatomical complexity inherent to CVS evaluation. To incorporate spatial context, segmentation-based methods [11, 14, 6] introduced pixel-level anatomical representations for more fine-grained scene understanding. Graph-based approaches [15, 16] have further explored structural modeling of surgical entities and their interactions. Moreover, recent multimodal approaches [1] have demonstrated the potential of vision-language pretraining, aligning surgical visual features with criterion-level textual descriptions to incorporate semantic knowledge beyond pure visual appearance.

Despite these advancements, existing methods [11, 14, 1, 17] typically treat CVS assessment as a holistic prediction task, mapping visual features directly to criterion-level labels. This black-box paradigm lacks explicit reasoning about anatomical relationships, limiting both interpretability and compositional generalization. In fact, CVS evaluation inherently depends on the structural relationships among key anatomical entities in the hepatocystic triangle [10]. For example, confirming hepatocystic triangle clearance requires verifying that the cystic duct and cystic artery are the only two structures entering the gallbladder, demanding fine-grained relational reasoning rather than global appearance matching. Therefore, this strong structural dependency motivates us to decompose CVS assessment into fine-grained anatomical verification with a traceable rationale.

To address this, we propose ReasonCVS, a structured reasoning agentic framework empowered by Vision-Language Models (VLMs) that decomposes CVS assessment into explicit, fine-grained anatomical verification. Specifically, we first devise an Anatomical Scene Graph Abstraction (ASGA) that organizes anatomical entities and their spatial relationships into a structured representation. We then design the VLM-driven Sub-criterion Verifier to parse the graph and independently evaluate individual sub-criteria. A Rationale-Aware Reasoning

Figure

Fig. 2. The overview of our ReasonCVS framework for interpretable CVS assessment, consisting of Anatomical Scene Graph Abstraction (ASGA), VLM-driven Sub-criterion Verification, and Rationale-Aware Reasoning Agent. ReasonCVS decomposes CVS assessment into explicit anatomical verification with traceable clinical rationale.

Agent, fine-tuned via rationale distillation, serves as the central decision-maker that invokes these Verifications and synthesizes distributed observations through calibrated soft reasoning, yielding a final verdict alongside a traceable clinical rationale. To the best of our knowledge, ReasonCVS is the first framework to address CVS assessment through structured reasoning. Experiments demonstrate that ReasonCVS achieves superior performance over state-of-the-art methods.

References (27)

  • Multi-modal representations for fine-grained multi-label critical view of safety recognition
  • Safe cholecystectomy multi-society practice guideline and state-of-the-art consensus conference on prevention of bile duct injury during cholecystectomy
  • SAM 3: Segment Anything with Concepts
  • Artificial intelligence in surgery: promises and perils
  • Lora: Low-rank adaptation of large language models
  • Artificial intelligence for intraoperative guidance: using semantic segmentation to identify surgical anatomy during laparoscopic cholecystectomy
  • Surgical data science—from concepts toward clinical translation
  • Surgical data science for next-generation interventions
  • Endoscapes, a critical view of safety and surgical scene segmentation dataset for laparoscopic cholecystectomy
  • Computer vision in surgery: from potential to clinical value
  • Artificial intelligence for surgical safety: automatic assessment of the critical view of safety in laparoscopic cholecystectomy using deep learning
  • The endoscapes dataset for surgical scene segmentation, object detection, and critical view of safety assessment: Official splits and benchmark (opens arXiv in a new tab)
  • Encoding surgical videos as latent spatiotemporal graphs for object and anatomy-driven reasoning
  • Latent graph representations for critical view of safety assessment
  • Rendezvous: Attention mechanisms for the recognition of surgical action triplets in endoscopic videos
  • 4d-or: Semantic scene graphs for or domain modeling
  • Cholec80-cvs: An open dataset with an evaluation of Strasberg's critical view of safety for ai
  • Rationale and use of the critical view of safety in laparoscopic cholecystectomy
  • An analysis of the problem of biliary injury during laparoscopic cholecystectomy
  • Gemini: A Family of Highly Capable Multimodal Models
  • Endonet: a deep architecture for recognition tasks on laparoscopic videos
  • Videos as space-time region graphs
  • Causes and prevention of laparoscopic bile duct injuries: analysis of 252 cases from a human factors and cognitive psychology perspective
  • Qwen3 Technical Report
  • Procedure-aware surgical video-language pretraining with hierarchical knowledge augmentation
  • Hecvl: Hierarchical video-language pretraining for zero-shot surgical phase recognition
  • Learning multi-modal representations by watching hundreds of surgical video lectures