arXiv:2609.10961cs.LGSep 2026

Manuscript Offprint

arXiv:2609.10961

When More Is Not Better: Component Anti-Synergy in a P300 Speller

Lucas Yang, Rui Liu, Fusheng Wang

Lucas Yang

Parkland High School

Allentown, PA, USA

yanglucas2028@gmail.com

Rui Liu

Dept. of Computer Science

Stony Brook University

Stony Brook, NY, USA

ruiliu1@cs.stonybrook.edu

Fusheng Wang

Dept. of Computer Science

Dept. of Biomedical Informatics

Stony Brook University

Stony Brook, NY, USA

fusheng.wang@stonybrook.edu

Abstract—P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that “more-is-better.” We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal “all-on” pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

Index Terms—Brain-computer interface, P300 speller, Euclidean Alignment, xDAWN, subject calibration

I. INTRODUCTION

For people with severe communication and motor impairments, including individuals with amyotrophic lateral sclerosis (ALS), loss of speech and movement can make conventional input devices difficult or impossible to use [1]. Brain–computer interface (BCI) spellers offer a hands-free alternative by translating brain activity into character selections [2]. In a P300 speller using the Farewell-Donchin grid, rows or columns of a character matrix flash while the user attends to a target. The resulting P300 event-related potential (ERP) in the electroencephalography (EEG) signal is used to infer the intended character [3]. Practical systems must balance communication accuracy and efficiency, system calibration complexities, and robustness across distinct users.

Modern P300 pipelines combine multiple components to address these goals: Euclidean Alignment (EA) supports cross-subject/session transfer, xDAWN (XD) enhances P300 spatial representation, subject calibration (CB) personalizes the decoder, and language models (LM) offer contextual priors [4]–[7]. Although each one has demonstrated value, prior studies typically evaluate individual modules or aggregate pipeline performance, leaving their interactions unclear. Individually useful components may become complementary, redundant, or interfering when combined.

This uncertainty is especially notable for zero- or low-calibration settings, which reduce setup burden but also limit subject-specific adaptability [8] and require other components to compensate for missing calibration. Moreover, although LM and, more recently, large language model (LLM) priors may improve contextual prediction, it remains unclear whether their effects depend on the strength of the underlying EEG evidence shaped by other pipeline components [7], [9]. We therefore ask: (1) Are component effects additive, redundant, or anti-synergistic? (2) How do component behaviors differ with versus without calibration, and can any partially compensate for its absence? (3) How do LM and LLM priors behave when EEG decoding is well-aligned, personalized, or weak?

We address these questions using a public P300 matrix-speller dataset containing 10 subjects across three sessions [10], [11]. During processing, EA, xDAWN, calibration, and LM support were independently enabled or disabled in a 24=162^{4} = 16 full-factorial design. Performance was evaluated using accuracy, repetitions per character, and information transfer rate (ITR) with linear mixed-effects models. Robustness was assessed using a larger LM, an alternative random-effects specification, and cross-session curation.

Our contributions are:

• We show through full-factorial analysis that P300 component value is conditional rather than additive and identify configurations with redundancy penalties.

  • We clarify zero-calibration design: calibration is the dominant contributor, while xDAWN benefits uncalibrated decoding only when paired with EA and can reduce efficiency once EA and calibration are both present.

  • We establish a boundary condition for LM/LLM support: language priors are harmful when EEG evidence is insufficiently aligned or personalized, whereas calibration largely neutralizes their interference.