arXiv:2608.20322cs.LGAug 2026

Manuscript Offprint

arXiv:2608.20322

A comparison between ceiling-mounted FMCW, IR-UWB and Wi-Fi radar for in-bedroom human activity monitoring and sleep interruption detection

Anton Lambrecht, Reda El Hail, Xianjun Jiao, Pieter Crombez, Dominique Schreurs, Peter Karsmakers, Adnan Shahid, Eli De Poorter

arXiv:2608.20322v1 [cs.LG]

IEEE Access Multidisciplinary Rapid Review Open Access Journal

Date of publication xxxx 00, 0000, date of current version xxxx 00, 0000.

Digital Object Identifier PLACEHOLDER

A comparison between ceiling-mounted FMCW, IR-UWB and Wi-Fi radar for in-bedroom human activity monitoring and sleep interruption detection

ANTON LAMBRECHT 1^{1}, REDA EL HAIL 2,3^{2,3}, XIANJUN JIAO 1^{1}, PIETER CROMBEZ 4^{4}, DOMINIQUE SCHREURS 5^{5}, PETER KARSMAKERS 2,3^{2,3}, ADNAN SHAHID 1^{1}, AND ELI DE POORTER 1^{1}

IDLab, Department of Information Technology, Ghent University-imec, iGent Tower, Technologiepark-Zwijnaarde 126, B-9052 Ghent, Belgium. (email: Anton.Lambrecht@Ugent.be)

Department of Computer Science, Leuven AI, KU Leuven, B-2440 Geel, Belgium (e-mail: Reda.Elhail@kuleuven.be)

Flanders Make, MPRO, B-3000 Leuven, Belgium (e-mail: Reda.Elhail@kuleuven.be)

Televic Healthcare, 8870 Izegem, Belgium

Div. ESAT-WAVECORE, KU Leuven, Belgium (e-mail:dominique.schreurs@kuleuven.be)

Corresponding author: Anton Lambrecht (email: Anton.Lambrecht@Ugent.be).

The research that led to these results has received funding from the DistriMuSe project (HORIZON-KDT-JU-2023-2-RIA) with Grant No 101139769, the CORNET project DARTS (HBC.2023.0772) and from the NAV-ALERT project from the Belgian Defense through contract number 24DEFRA009.

ABSTRACT

Despite their growing importance for contact-free radio frequency (RF) based healthcare monitoring, different radio technologies such as frequency-modulated continuous wave (FMCW) radar, impulse radio ultra-wideband (IR-UWB), and Wi-Fi sensing are rarely compared under identical deployment conditions, as existing studies typically differ in hardware, datasets, and evaluation methodologies. In addition, the performance of ceiling-mounted radars, despite their practical deployment and cost advantages in healthcare environments, remain underexplored. Therefore, this paper presents a controlled comparison and analysis of ceiling-mounted FMCW, IR-UWB, and Wi-Fi sensing using synchronized recordings from 20 participants across six room layouts. All technologies are evaluated with the same convolutional neural network (CNN) on both a fine-grained 10-class human activity recognition (HAR) task and a coarse 4-class sleep monitoring task. IR-UWB achieves the highest cross-subject activity recognition performance (89.0% macro F1), while FMCW generalizes best to unseen room layouts (83.8% macro F1). For sleep monitoring, all technologies exceed 92% macro F1 in unseen environments. The results reveal a fundamental trade-off between recognition performance and environmental robustness, which can be explained through differences in range resolution, antenna diversity, Doppler resolution, and spatial information retention. These findings provide practical guidelines for the design of healthcare-oriented RF sensing systems.

INDEX TERMS ceiling-mounted, convolutional neural networks, FMCW radar, human activity recognition, impulse-radio ultra-wideband (IR-UWB), remote healthcare, sensor comparison, sleep monitoring, Wi-Fi radar

References (21)