Abstract

Wireless Capsule Endoscopy (WCE) has emerged as a non-invasive and patient-friendly imaging modality for comprehensive visualization of the Gastrointestinal (GI) tract. However, due to the miniaturized capsule design, limited onboard optics, sensor constraints, and wireless transmission bandwidth restrictions, WCE images are inherently acquired at low spatial resolution, often accompanied by noise, motion blur, and illumination degradation. These limitations significantly reduce the visibility of fine anatomical structures such as mucosal textures, vascular patterns, and lesion boundaries, thereby affecting diagnostic reliability. To address this challenge, this paper proposes a computationally efficient unsupervised Transformer-based super-resolution framework, termed as CEM-TUDASR, for enhancing WCE images without relying on paired Low-Resolution (LR) and High-Resolution (HR) training data. The proposed framework integrates a domain-adaptive degradation modeling network that learns to synthesize realistic WCE-like LR images from HR conventional endoscopy images, enabling effective unpaired training and reducing the domain discrepancy between conventional and capsule endoscopy data. Furthermore, a Transformer-based SR generator incorporating Deep Attention Blocks (DABs) and a Fusion Attention Block (FAB) is introduced to jointly capture long-range contextual dependencies and fine-grained local structural details. This architecture facilitates improved reconstruction of diagnostically relevant regions while preserving structural consistency and perceptual fidelity. The proposed model is trained on a newly curated WCE dataset derived from the Kvasir Capsule dataset and extensively evaluated on external benchmark datasets, including KID and GIANA, to validate its effectiveness and generalization capability. Quantitative evaluation using no-reference image quality assessment metrics, including BRISQUE, PIQE, NIQE, and the domain-specific EndoQM, demonstrates that the proposed method consistently outperforms existing unsupervised SR approaches in terms of perceptual quality, structural preservation, and domain-specific visual fidelity. Qualitative analysis further confirms superior restoration of subtle mucosal textures, vascular structures, and clinically significant anatomical details essential for accurate interpretation. In addition, cross-domain evaluation on retinal images demonstrates the robustness and adaptability of the proposed framework across diverse medical imaging modalities. Despite achieving high-quality reconstruction performance, the proposed architecture maintains computational efficiency with only 2.67 million parameters and 169.94 GFLOPs, making it highly suitable for deployment in real-time and resource-constrained clinical environments, including portable and embedded endoscopic systems. GitHub Link: https://github.com/Jay042003/CEM-TUDASR.git

Keywords: Wireless Capsule Endoscopy, Super Resolution, Transformer, Unsupervised, Kvasir dataset

arXiv:2609.00001

1. Introduction

In the medical field, optical colonoscopy is a gold standard technology for the early detection, diagnosis, and treatment of significant disorders related to both, upper and lower Gastrointestinal (GI) tract of human body. It is useful for Colorectal Cancer (CRC), Crohn's disease, ulcerative colitis, hemorrhoids, and inflammation. While this has acknowledged significant clinical efficacy in reducing CRC incidence, it remains invasive procedure with suboptimal sensitivity in detecting adenomatous polyps. Thus, despite of approximately 19 million colonoscopies being performed annually in the United States, routine screenings exhibit a polyp miss rate ranging from 6% to 28%, contributing to CRC's status as the second most prevalent cancer and leading cause of cancer-related mortality [1]. Additionally, the small intestine presents a significant challenge for examination using conventional endoscopes due to its anatomical complexity, and traditional procedures which often induce substantial patient discomfort and pain. To avoid these limitations, Wireless Capsule Endoscopy (WCE) is an effective alternative technology introduced recently which enables comprehensive visualization of the entire GI tract and facilitating the detection of adenomatous polyps and non-polypoid lesions that may contribute to CRC progression [2]. Unlike conventional endoscopes, WCE device is a capsule-shaped imaging system that is swallowed by the patient and, captures real-time video of the GI tract without requiring sedation or extensive bowel preparation. Thus, it is a non-invasive, patient-friendly and painless technology which provides easy diagnosis of irregularities associated with the entire GI tract including small intestine [3]. However, this forthcoming technology is constrained by hardware limitations, resulting in sense Low-Resolution (LR) images with sig-significant noise and degradation, making the identification of colorectal cancer polyps challenging for endoscopists [4]. Hence, it limits the detection of likelihood of missed diagnoses which also reduces diagnostic accuracy.

To address above issue, Super-Resolution (SR) techniques are often incorporated as an effective solution to reconstruct High-Resolution (HR) images from their LR counterparts without additional imaging time [5]. By enhancing image fidelity and structural details, SR techniques provide higher-quality visualizations that improve both manual assessment by endoscopists and the performance of automated polyp detection algorithms, ultimately enhancing diagnostic require in clinical settings. Additionally, to analyze the domain discrepancy between natural images and WCE images, we computed the Gradient Magnitude Distribution (GMD) for both data in Fig. 1 in Supplementary material which shows the necessity for specialized SR models that incorporate domain-specific characteristics and robust adaptation strategies to bridge the gap between natural and clinical imaging domains.

Previously, numerous SR models based on deep learning have been actively explored due to the availability of computing resources and datasets, from early methods using Convolutional Neural Networks (CNNs) (i.e., SRCNN [6, 7, 8]) to the promising SR methods using transformers (i.e., TTSR [9]) for natural images. Due to the exceptional performance of deep learning based SR methods for RGB data, they are also experimented to the traditional endoscopic images [10, 11, 12, 13]. However, improving the reconstruction accuracy to the WCE data is still relatively underexplored mainly due to reasons listed in Supplementary material. Moreover, these SR approaches for natural and medical images usually employ supervised training, where models learn to upscale LR images by leveraging paired LR and HR images. The availability of HR endoscopy images is limited, and acquiring well-aligned LR-HR image pairs in the medical domain is particularly challenging [14]. In some cases, synthetic generation of these LR-HR pairs is considered; however, this approach is only feasible when the image acquisition process is meticulously controlled and well-defined. Typically, only an approximate understanding of the acquisition process is available, and LR images are often simulated using known downsampling techniques, such as bicubic downsampling. Consequently, supervised SR models are trained on these synthetic LR-HR pairs, where the LR images do not correspond to true camera-captured observations. As a result, such models tend to learn the degradation patterns of simulated LR samples, limiting their ability to generalize to real-world, clinically obtained LR images [12, 15, 7]. The challenge is further exacerbated in medical imaging, where generating true LR-HR pairs by manipulating camera settings is impractical and often infeasible.

To circumvent the above-listed limitations, we propose CEM-TUDASR, a deep learning SR architecture that is trained in an unsupervised manner, eliminating the need for precisely aligned LR-HR WCE image pairs. The unsupervised training approach allows the model to learn directly from the available data without relying on synthetic pairings, thus improving its generalization performance when applied to real-world WCE images. Here, we introduce a Generative Adversarial Network (GAN)-based transformer architecture that leverages adversarial learning to reconstruct visually realistic SR images with rich high-frequency details. It is important to note that since the vast majority of CNNs for medical imaging makes use of rather small convolution kernels (i.e., 3×33 \times 3 or 5×55 \times 5), such local convolution operations results in the CNNs being biased towards local spatial structures, which makes them less effective at modeling the long-range dependencies required to better comprehend the contextual information presented in the image [16].

Transformers, as an alternative network architecture to CNNs, has recently demonstrated superior performance in many computer vision tasks [17, 18]. The core element of a transformer is the self-attention mechanism, which is not subject to the same limitations as convolution operations, making it better at capturing explicit long-range dependencies. Additionally, Transformers have other appealing features, such as they scale up more easily and also more robust to corruption. Further, their weak inductive bias enables them to achieve better performance than CNNs with the aid of large-scale model sizes and datasets. The existing Transformer-based models have shown encouraging results in several medical imaging applications, prompting a surge of interest in further developing such models [19]. Thus, the proposed design (i.e., CEM-TUDASR) addresses the inherent limitations of conventional architectures in recovering fine anatomical structures, enabling the generation of perceptually consistent and diagnostically meaningful outputs. Importantly, the entire framework is trained in an unpaired setting, eliminating the need for aligned LR-HR image pairs. This enables the model to jointly learn domain-aware degradation and SR reconstruction processes in a fully unsupervised manner, enhancing its adaptability and clinical relevance across real-world WCE scenarios. Thus, it improves the practical applicability of SR in real-world clinical settings where paired data are unavailable.

From a broader clinical and societal perspective, improved WCE image quality can significantly support gastroenterologists in the early detection and diagnosis of gastrointestinal abnormalities such as bleeding [20], ulcers [21], inflammation, and colorectal lesions. Better visualization of subtle pathological features can reduce the risk of missed diagnoses, improve diagnostic confidence, and enhance patient outcomes. In addition, the computational efficiency of the proposed framework facilitates its deployment in portable and resource-constrained healthcare environments, contributing to more accessible and reliable diagnostic support systems for large-scale clinical use. The overall motivation, aim, novelty, and objectives are highlighted in the following form.

References (46)