arXiv:2609.11312cs.CVSep 2026

Manuscript Offprint

arXiv:2609.11312

GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT

Haojie Yang, Ran Su

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Haojie Yang, Ran Su ∗^{*}

College of Intelligence and Computing, Tianjin University, Tianjin, China

haojae@tju.edu.cn, ran.su@tju.edu.cn

∗^{*}Corresponding author

Abstract—Lung cancer causes more deaths than any other malignancy, and low-dose CT screening is the main pathway to early diagnosis. That pathway hinges on the smallest lesions, yet nodules below six millimeters remain hard to detect, because most methods treat a nodule as a generic object and ignore the imaging physics behind its appearance. We show that this appearance is highly regular. Intensity peaks at the geometric center of a nodule and decays radially in a Gaussian pattern, and a fit to 18,218 annotated lesions from three public benchmarks yields a mean radial coefficient of determination above 0.86 in every dataset and size stratum. A square convolution samples both axes uniformly and is mismatched to this radial signal, most severely for small nodules. Guided by this evidence, we propose GRIPNet (Gaussian Radial Intensity Prior Network), a detector in which every module maps to a measurable property of the intensity distribution. Pinwheel convolutions decompose radial gradients, a dual-frequency module separates boundary detail from structural context, dilated masked attention matches the decay extent, and an adaptive loss reweights samples by conspicuity. GRIPNet raises mAP@0.5 to 95.3, 91.6 and 97.9 percent on KanserSet, LUNA16 and Lung-PET-CT-Dx while sharpening high-IoU localization at real-time speed.

Index Terms—pulmonary nodule detection, Gaussian radial intensity prior, CT image analysis, multi-scale feature fusion, asymmetric convolution

I. INTRODUCTION

Lung cancer remains the leading cause of cancer death worldwide [1]. Finding it early multiplies the five-year survival rate, and low-dose CT screening has become the standard route to that early diagnosis [2]. Deep detectors have improved steadily over the past decade [3], [4]. Even so, micro-nodules below 6 mm are still detected at only 65 to 75 percent sensitivity in routine reading, and ground-glass opacities with faint margins continue to confuse conventional feature extractors. The problem is structural rather than incidental. Most detectors treat a pulmonary nodule as a generic object and disregard the physical process that shapes its CT appearance [5], so they spend capacity relearning what a simple imaging prior would already provide.

A pulmonary nodule is far from a structureless region. Its CT appearance follows the partial-volume effect acting on a roughly spherical mass embedded in aerated parenchyma. Peak Hounsfield values concentrate at the geometric center and fade outward, as Fig. 1 shows. When a Gaussian is fitted to the radial profile, the mean coefficient of determination exceeds 0.86 across three public benchmarks. A conventional square kernel samples both axes evenly. It is therefore geometrically

Figure

Figure

Figure

Fig. 1: Gaussian-like radial intensity profile of a pulmonary nodule. Peak HU values concentrate at the geometric center and attenuate radially.

mismatched to these radial gradients and spends capacity on directions that carry little signal, and the mismatch hurts most on small nodules.

We propose GRIPNet, a Gaussian Radial Intensity Prior guided network in which every design choice traces to a quantifiable property of the nodule intensity distribution. Asymmetric pinwheel convolutions [6] decompose radial gradients along orthogonal axes. A dual-frequency module separates boundary detail from structural context. Dilated masked attention calibrates its receptive field to the Gaussian decay extent. An adaptive loss evolves its difficulty threshold as training progresses. These components form a coherent pipeline on a YOLOv11 backbone [7] that reaches state-of-the-art accuracy at real-time speed.

The paper offers three contributions. We show that pulmonary nodule intensity profiles obey a Gaussian radial model, with a mean radial R2R^{2} above 0.86 on three large-scale CT datasets. On that evidence we build GRIPNet, in which every module derives from a measurable physical property rather than from a generic architecture search. The resulting detector improves consistently over strong baselines, including recent lung-nodule-specific methods, and reaches a mAP@0.75 of

89.2% on KanserSet at real-time throughput.

References (29)