arXiv:2609.11650cs.CVSep 2026

Manuscript Offprint

arXiv:2609.11650

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

John Bonnici, Matthew Baugh, Aleksandra Kulbaka, Sarah Cechnicka, Bernhard Kainz, Alberto Gomez

John Bonnici 1^{1} ID^{ID}, Matthew Baugh 1^{1} ID^{ID}, Aleksandra Kulbaka 1^{1} ID^{ID}, Sarah Cechnicka 1^{1} ID^{ID}, Bernhard Kainz 1,2^{1,2} ID^{ID}, and Alberto Gomez 3^{3} ID^{ID}

1^{1} Departament of Computing, Imperial College London, UK

john.bonnici21@imperial.ac.uk

2^{2} Friedrich-Alexander University Erlangen-Nürnberg, DE

3^{3} Ultromics Ltd, Oxford, UK

Abstract. Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/

Keywords: Echocardiography · Cardiac phase detection · Self-supervised learning · Motion-structure disentanglement · Latent trajectories

1 Introduction

Cardiovascular disease is the leading cause of death worldwide [9,20]. Transthoracic echocardiography is the primary imaging modality for cardiac assessment

J. Bonnici et al.

due to its portability, low cost, and real-time acquisition [3]. Cardiac function is often quantified using left ventricular ejection fraction (LVEF), which measures the proportion of blood ejected from the left ventricle during each heartbeat. Estimating LVEF requires accurate identification of end-diastole (ED) and end-systole (ES) frames [3,8], yet manual selection is subjective, with substantial inter-operator ejection-fraction variability [12,19]. Automated, annotation-free ED/ES detection could therefore improve clinical reproducibility and the scalability of large cohort studies.

Recent work on self-supervised motion-structure decomposition has shown that an autoencoder trained purely on video reconstruction can separate a static structural component from a low-dimensional motion trajectory, and that cardiac phase can be recovered from the geometry of that trajectory without any labels [21,22]. However, existing formulations leave the motion coefficients unconstrained, allowing points to arbitrarily span the low-rank subspace [16,11]. As a result, phase extraction requires post-hoc signal processing, such as principal-axis projection or RANSAC-based orientation detection.

We address the same problem using a strong physiological prior implemented directly in the disentangled latent space. In the apical four-chamber view (A4C), cardiac motion presents multiple simultaneous patterns: LV, RV, and atrial contraction and relaxation, valve motion, and out-of-plane motion of some structures; however, cardiac phase is a scalar signal that determines the temporal position within the cycle. In contrast with competing methods, we replace a multi-dimensional latent motion representation with a single-parameter latent orbit - a line segment in latent space indexed by a bounded scalar phase variable - and propose a latent disentanglement approach that promotes phase separation. Our contributions are as follows:

(1) We propose a single-parameter latent orbit model that encodes cardiac phase as a cyclic traversal of a one-dimensional trajectory. (2) We show that ED and ES can be retrieved directly from the minima and maxima of the learned phase signal. (3) Trained on EchoNet-Dynamic without ED or ES labels, we show that our model improves ED localisation and matches ES localisation while using a more constrained representation and fewer training epochs, achieving strong downstream EF prediction performance and cycle consistency with a principled, minimal-parameter design.

Related work. Supervised ED/ES detection methods use CNN-RNN hybrids [5,6,18], vision transformers [15], multi-task fetal networks [14], and indirect derivation from volume curves or segmentation masks [13,23], but require costly annotations. Among unsupervised approaches, early manifold-learning methods used locally linear embedding to detect phase from trajectory density [2,17], while the training-free DDSB method [1] exploited expansion-contraction dynamics but was sensitive to short ED/ES intervals. DeepHeartBeat [4] constrained motion to a circular trajectory with fixed frequency and shape, improving periodicity but limiting flexibility to beat-to-beat variability. Latent motion profiling (LMP) [21] introduced self-supervised motion-structure decomposition via a joint task of frame-wise and mean frame reconstruction, using

Figure

Fig. 1. Each frame in the input clip is encoded into a latent space and temporally mixed. This representation is processed by two branches: the structure branch (top) computes the clip-level mean and maps it to a static latent s\mathbf{s}; and the motion branch (bottom) predicts frame-level phase values ϕt\phi_t, projecting through a learned sinusoidal vector a∈RD\mathbf{a} \in \mathbb{R}^D into the motion latent mt\mathbf{m}_t. The latent zt=s+mtz_t = \mathbf{s} + \mathbf{m}_t is decoded to reconstruct the input.

an unconstrained two-dimensional motion subspace. LMP achieved state-of-the-art performance among annotation-free ED/ES detection methods when tested on EchoNet-Dynamic. Its orientation-robust extension ORBIT [22] adapted this paradigm to fetal imaging using registration-based self-supervision.

We build on the motion-structure decomposition of [21] but replace unconstrained motion coefficients with a single-parameter orbit derived from the prior that cardiac phase is one-dimensional.

References (22)