arXiv:2609.09577eess.IVSep 2026

Manuscript Offprint

arXiv:2609.09577

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Thierry Judge, Nicolas Duchateau, Andreas Østvik, Havard Dalen, Bjørnar Grenne, Pierre-Yves Courand, Lasse Lovstakken, Pierre-Marc Jodoin, Olivier Bernard

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Thierry Judge 1,2^{1,2}, Nicolas Duchateau 2,3^{2,3}, Andreas Østvik 4,5,6^{4,5,6}, Havard Dalen 4,5,7^{4,5,7}, Bjørnar Grenne 4,5^{4,5}, Pierre-Yves Courand 2,8^{2,8}, Lasse Lovstakken 4^{4}, Pierre-Marc Jodoin 1^{1}, and Olivier Bernard 2,3^{2,3}

1^{1} Dept. of Computer Science, University of Sherbrooke, Sherbrooke, Canada.

2^{2} INSA, Université Lyon 1, CNRS UMR 5220, Inserm U1206, CREATIS, Villeurbanne, France.

3^{3} Institut Universitaire de France (IUF).

4^{4} Dept. of Circulation and Medical Imaging, NTNU, Trondheim, Norway

5^{5} Dept. of Cardiology and Cardiothoracic Surgery, St. Olavs Hospital, Trondheim, Norway

6^{6} Dept. of Health Research, SINTEF Digital, Trondheim, Norway

7^{7} Dept. of Medicine, Levanger Hospital, Nord-Trøndelag Hospital Trust, Levanger, Norway

8^{8} Cardiology Dept., Hôpital Croix-Rousse, Hospices Civils de Lyon, Lyon, France, and the Cardiology Dept., Hôpital Lyon Sud, Hospices Civils de Lyon, Lyon, France.

Abstract. Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice. Code is available at https://github.com/ThierryJudge/cardiac-motion.

Keywords: Myocardial tracking · Drift correction · Echocardiography.

1 Introduction

Myocardial strain, which quantifies the deformation of the cardiac wall across the cycle, is highly informative for the assessment of cardiac dysfunction [13]. In speckle tracking echocardiography (STE), it can be quantified locally after

T. Judge et al.

tracking speckle patterns, this technique being the clinical standard available in several clinical software packages. However, such software packages may not be fully transparent regarding the post-processing involved (hence the lack of consensus about computational standards [17]) and are not freely available. Besides, their performance may be limited on lower-quality images as often encountered in clinical routine.

In contrast, deep learning methods derived from optical flow estimation have the potential to overcome these limitations. Such methods are either trained on a large dataset of labels acquired with speckle tracking [1,2], or a simulated dataset generated with known motion [3,16,7]. In both cases, while the deep learning-based methods can achieve competitive results with speckle tracking, they often lack physiological constraints in their training. One major constraint is drift, which refers to the accumulation of errors across the sequence, resulting in different (and sometimes divergent) strain values from one cycle to another. Without drift, strain should theoretically be zero at every end-diastolic (ED) instant, for purely cyclic sequences. This phenomenon is most evident when strain values, such as Global (GLS) or Regional Longitudinal Strain (RLS), do not return to zero at the end of the cycle, reflecting a mismatch between the final and initial relative positions of the tracked points. Despite its importance, drift is not explicitly addressed in most tracking approaches. Existing deep learning models are largely adapted from general-purpose tracking architectures developed for natural images and do not enforce cyclic consistency. Current commercial solutions typically rely on a posteriori drift correction, which is suboptimal as it does not influence the tracking process itself.

In this work, we propose a deep learning framework for myocardial tracking that explicitly accounts for drift and enforces physiologically consistent cyclic motion. Our approach extends the TAS-Net model with mechanisms to capture long-range temporal dependencies across the full cardiac cycle. In addition, we introduce a teacher-student fine-tuning strategy on real echocardiographic data, combining a novel drift loss with shape-preserving and temporal regularization terms. By integrating these constraints directly into the learning process, our method improves the reliability of myocardial strain estimation and reduces drift without compromising tracking accuracy.

References (17)