Paper record
W2468685308Análise de concordância em estudos clínicos e experimentais
Hélio Amante Miot
- Year
- 2016
- Venue
- Jornal Vascular Brasileiro
- References
- 21
- Cited by
- 154
Details and counts from OpenAlex.
Abstract
Analysis of agreement tests the capacity to arrive at identical results (with the same units of measurement), for the same subject/phenomenon, using different instruments, using the same instrument at different times or when performed by different examiners, or some combination of these conditions. Trivial examples include calibration of instruments, testing reliability of scales/measures, assessment of the equivalence of measurement tools, judgment in tests of ability, tests of repeatability or reproducibility, and diagnostic analysis (interpersonal and intraindividual agreement) and psychometric agreement (temporal stability). 1,2 It is common for the need to analyze agreement to be, erroneously, met using statistical techniques for measurement of correlation (for example, Pearson's coefficients), which are only testing the assumption that the variation in the values of one variable follows the variation in the values of another. However, for analysis of agreement, in addition to correlation, there must also be coincidence of values. This is why measures of the effect size of agreement tend to be smaller than correlation coefficients, when applied to the same dataset. 3-5 The model of agreement analysis should be defined early on in the project design phase so that a study design is chosen to favor collection, analysis and interpretation of the data. Being able to count on an experienced statistician during this phase will increase the likelihood of success. In principle, analysis of agreement can depend exclusively on a definition predetermined by the researcher, who should define a tolerance limit that satisfies the research requirements. This is generally the case with calibration and equivalence of measurement instruments, in which measurements must conform to a maximum percentage variation in comparison with a standard measure or a specific instrument. However, the existence of an inherent random error of measurement linked to the instrument and/or the examiners includes an intrinsic variation in measurements, which interferes with estimation of agreement. Several different specific statistical tests have been developed to evaluate these aspects and the most important of them will be discussed below. The simplest situation occurs when the variable of interest is dichotomous (for example, sick vs. healthy, surgical indication vs. clinical, approved vs. rejected), and estimation is made by two examiners or with two instruments. In such cases, Cohen's kappa statistic is classically employed. The kappa value, confidence interval and statistical significance should all be interpreted as the magnitude of agreement that exceeds the degree of coincidence of assessments that would occur by chance. 6