Paper record
W2331215270Phenolic Impregnated Carbon Ablators (PICA) for Discovery class missions
Huy K. Tran, Christine Johnson, Daniel J. Rasky, Frank C. L. Hui, Ming‐Ta S. Hsu, Y. Chen
- Year
- 1996
- Venue
- AIAA Thermophysics Conference
- References
- 2
- Cited by
- 242
Details and counts from OpenAlex.
Abstract
This paper presents the development of the light weight Phenolic Impregnated Carbon Ablators (PICA) and its thermal performance in a simulated heating environment for planetary entry probes. PICA material was developed as a member of the Light Weight Ceramic Ablators (LCAs) family, and since then, the manufacturing process of this material was significantly unproved. The density of PICA material ranges from 0.224 to 0.321 g/cc having uniform resin distribution within the fibrous substrate. Surface densification was also developed to improve the ablation characteristics of PICA against extremely high stagnation pressures. The thermal performance of PICA was evaluated in the Ames arc jet facility at cold wall heat fluxes from 425 to 3360 W/cm and surface pressures of 0.1 to 0.43 attn. Heat loads used in these tests varied from 6,245 to 33,600 J/cm and are representative of the entry conditions of several proposed Discovery missions. Surface and in-depth temperatures were measured by using optical pyrometers and thermocouples. Surface recession was also measured by using a template and a height gage. The ablation characteristics and efficiency of the PICA is quantified by using the effective heat of ablation, and the thermal penetration response is evaluated by the thermal soak data. In addition, comparison of the thermal performance of standard and surface densified PICA is also discussed.