Paper record
W2154549868Contrast-limited adaptive histogram equalization: speed and effectiveness
Stephen M. Pizer, Richard E Johnston, James P. Ericksen, Bonnie C. Yankaskas, Keith E. Muller
- Year
- 2002
- Venue
- Conference on Visualization in Biomedical Computing (VBC)
- References
- 4
- Cited by
- 817
Details and counts from OpenAlex.
Abstract
An experiment intended to evaluate the clinical application of contrast-limited adaptive histogram equalization (CLAHE) to chest computer tomography (CT) images is reported. A machine especially designed to compute CLAHE in a few seconds is discussed. It is shown that CLAHE can be computed in 4 s after 5-s loading time using the specially designed parallel engine made from a few thousand dollars worth of off-the-shelf components. The processing appears to be useful for a wide range of medical images, but the limitations of observer calibration make it impossible to demonstrate such usefulness by agreement experiments.>