Paper record

W206554253

A Combined Adaptive Sample Size and Sampling IntervalX̄Control Scheme

Sharad S. Prabhu, Douglas C. Montgomery, George C. Runger

Year
1994
Venue
Journal of Quality Technology
References
15
Cited by
255

Details and counts from OpenAlex.

Abstract

A conventional X̄ control chart works in an open loop manner. That is, the process control engineer waits until the control scheme signals an out-of-control condition. This paper proposes a combined adaptive X̄ chart that uses real-time, dynamic information available from the process to make the control scheme proactive. The procedure consists of a simple method of varying the control chart design parameters (sample size and sampling interval) between minimum and maximum values depending on the current state of the process. The proposed procedure is compared with the standard Shewhart X̄ chart, a variable sample size chart, and a variable sampling interval chart in terms of the average time to signal an off-target process. Substantial improvement in the performance over these schemes is demonstrated. Optimal values for the maximum sample size are also given. The advantages of using the combined adaptive chart is illustrated by an example from a production process.