Paper record

W1987679258

Mode-R{\cal R} Subspace Projection of a Tensor for Multidimensional Harmonic Parameter Estimations

Yang Li, Jian Qiu Zhang

Year
2013
Venue
IEEE Transactions on Signal Processing
References
39
Cited by
10

Details and counts from OpenAlex.

Abstract

In Multidimensional Harmonic Retrieval (MHR) problems, it is understood that the multidimensional structure of the measurement data, with a tensor representation, can be exploited to improve the parameter estimation accuracy. In this paper, the mode-ℜ subspace of the tensor representation, based on the general matricization of the tensor, is first defined. It is found that there is a subordinate relation among the different mode- ℜ signal subspaces. As a result, the measurement tensor can be projected to the mode- ℜ signal subspaces in a bottom-up way, and the long-vector signal subspace required by the many signal subspace based parameter estimation algorithms can be refined. As an example, a mode-ℜ projection based Tensor-ESPRIT algorithm is presented. The reason why mode-ℜ subspace projections bring about performance improvement becomes obvious by the first order perturbation analyses. These analyses also generate two criteria on how the mode-ℜ subspace based projection technique should be carried out. Simulations are conducted to verify the effectiveness of the algorithm and the analytical results.