Paper record
W1983654537Examining Test-Retest Reliability: An Intra-Class Correlation Approach
Miaofen Yen, Li‐Hua Lo
- Year
- 2002
- Venue
- Nursing Research
- References
- 3
- Cited by
- 245
Details and counts from OpenAlex.
Abstract
BACKGROUND: There are limitations of inter-class correlation (usually, the Pearson's product-moment correlation) in evaluating reliability of an instrument. An intra-class correlation approach would be appropriate to examine the test-retest reliability of an instrument. OBJECTIVES: To introduce an intra-class correlation approach to examine the test-retest reliability of an instrument. METHOD: The method of constructing an intra-class correlation coefficient was presented. RESULTS: The instrument with visual analog scales to measure the perceived competence to practice breast self-examination and perceived barriers to breast self-examination was tested. The intra-class correlation coefficient was 0.640. CONCLUSION: The intra-class correlation is an alternative to test the reliability of an instrument and it is more sensitive to the detection of systematic error.