Paper record

W1870620040

A method for measuring horizontal and vertical eye movement chronically in the monkey.

Albert F. Fuchs, D.A. Robinson

Year
1966
Venue
Journal of Applied Physiology
References
0
Cited by
833

Details and counts from OpenAlex.

Abstract

measuring horizontal and vertical eye movement chronically in the monkey. J. Appl. Physiol. 21(s) : 1068-1070. I g66.-Eye move-ments are measured chronically in the monkey by surgically implanting a coil of fine wire upon the eyeball beneath the bulbar conjunctiva and recti insertions. The ends of the coil are led to a connector mounted on the monkey’s head. When the animal is exposed to two alternating magnetic fields in spatial and phase quadrature, signals generated in the coil on the eye may be phase detected to produce two voltages propor-tional to horizontal and vertical eye position with an accuracy of 15 min of arc. This technique makes it possible to record eye movements conveniently and accurately in the experimental animal in long- or short-term experiments on oculomotor func-tion as well as enabling the experimenter to control eye move-ments by training the animal in visual tracking tasks.