Paper record

W137568806

The Effect of Sample Size on Estimated Limits forX̄andXControl Charts

C. P. Quesenberry

Year
1993
Venue
Journal of Quality Technology
References
2
Cited by
369

Details and counts from OpenAlex.

Abstract

The results of this study indicate that X̄ charts with subgroups of size n require about 400/(n-1) samples, and X charts require about 300 values to estimate control limits that perform like known limits. The results also indicate that using estimated control limits results in charts for which the events that individual points exceed the control limits are dependent. One result of this dependence in a charting program is to increase the rate of false alarms after short runs, even though the ARL is increased. The implications of this to the use of Q charts are discussed.